Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD01-01054
StatusFinaled
Name STEED CONSTRUCTION
Site Address 10185 W EMERALD ST
Project NameEMERALD BLDG (E)
Customer Number 
ePlanReviewNo
Description
EMERALD TECH CENTER BUILDING "E" (SHELL) - TO CONSTRUCT A NEW 15,000 SQUARE FOOT, ONE STORY, SHELL BUILDING, CONSTRUCTED OF CONCRETE TILT-UP EXTERIOR WALLS WITH INTERIOR STEEL STRUCTURAL COLUMNS, STEEL ROOF JOISTS WITH METAL ROOF DECK AND SINGLE PLY ROOFING SYSTEM. THIS BUILDING IS FULLY FIRE SPRINKLED. THIS PERMIT ALSO INCLUDES RELATED SITE IMPROVEMENTS. THIS IS A SHELL PERMIT ONLY, NO OCCUPANCY IS ALLOWED UNDER THIS PERMIT. SEPARATE TENANT IMPROVEMENT PERMITS ARE REQUIRED T FINISH EACH TENANT SPACE FOR OCCUPANCY. ALL CONSTRUCTION PER THE APPROVED PLANS AND ATTACHED COMMENT LIST. DRH00-00105/JCM CUP01-00001 PC#349-01
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  2/16/2005  
Case Summary (BLD)  6/24/2003  
Fee Review-notes4/25/20014/25/20014/15/2002 DONE
Letter of compliance  4/8/2002 DONE
Letter of Compliance #22324 issued 4-8-02.
BLD-Final4/5/20024/5/20024/5/2002PPASS
DetailsRuss Owen
Scheduled by a contractor via Hello! on 04/05/2002 at 09:52:26. Contact: ###-####.ok for perm oc, received letter from engineer and special inspection firm. all ok. 4/5/2002 5:45:30 PM
BLD-Final4/3/20024/3/20024/3/2002PPART
DetailsRuss Owen
###-#### JIM ok temp oc , need special inspection final letter. may be in office ? c/n posted.2 5:03:49 PM 4/3/2002 5:04:27 PM 4/3/2002 5:04:37 PM
FIRE-Final Inspection4/3/20024/3/20024/3/2002PPASS
DetailsTroy Cobbley
fire life safety finaled. fire sprinkler finaled
FIRE-Final Inspection3/28/20023/28/20023/28/2002PFAIL
DetailsRick Jackson
Scheduled by Inspector: 409 On 3/28/2002 5:21:37 PM need second phone line for alarm monitoring 3/28/2002 5:24:20 PM
BLD-Energy code compliance3/22/20023/25/20023/25/2002ACANC
DetailsRuss Owen
Scheduled by a contractor via Hello! on 03/22/2002 at 17:10:20. Contact: ###-####.
FIRE-Final Inspection3/22/20023/25/20023/25/2002ANR
DetailsTroy Cobbley
There was no inspection. The contractor just wanted to know how many fire extinguishers he needed 3/25/2002 9:13:36 AM
BLD-Final3/22/20023/25/20023/25/2002PNR
DetailsRuss Owen
Scheduled by a contractor via Hello! on 03/22/2002 at 17:12:25. Contact: ###-####.needs all signatures and s-i final letter. PM 3/25/2002 4:46:44 PM
BLD-Aging Inspection1/7/20021/7/20021/7/2002 PART
DetailsRuss Owen
wip. 1/7/2002 5:57:41 PM
BLD-Concrete10/16/200110/17/200110/17/2001APART
DetailsDave Hannah
Scheduled by a contractor via Hello! on 10/16/2001 at 18:06:46. Contact: ###-####. rebar and concrete inspected using specal inspection 10/17/2001 10:32:17 AM
BLD-Concrete10/11/200110/12/200110/12/2001APART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 10/11/2001 at 19:31:23. Contact: ###-####. Subject to s-i. 10/12/2001 12:19:51 PM
BLD-Footing9/25/20019/26/20019/26/2001AFAIL
DetailsDave Hannah
Scheduled by a contractor via Hello! on 09/25/2001 at 13:39:00. Contact: ###-####. poured with out city inspection dont know if spec inspection was done no one for steed on site 9/26/2001 11:07:07 AM
BLD-Footing9/22/20019/24/20019/24/2001APART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 09/22/2001 at 09:42:07. Contact: ###-####. Special inspection will be performed. 9/24/2001 4:40:22 PM
(F) Reprint permit  9/17/2001 DONE
Issue PAID IN FULL permit  9/14/2001 DONE
Telephone call  7/18/2001 DONE
Told them they would have until October to pick up permit (180 days since they applied for permit)
Inspection Record Card- Bld  6/22/2001 DONE
Print Occupancy Form  6/22/2001 DONE
Telephone call  6/22/2001 DONE
LEFT MESS THAT PERMIT IS READY
Routing - PLANNING6/19/2001 6/21/2001 PASS
Approve per DRH00-105
Routing - PLAN CHECK6/21/2001 6/21/2001 PASS
PLANS/APPL TAKEN TO FRONT DESK  6/21/2001 PASS
Plan assigned to (JCM)4/26/2001 6/21/2001 PASS
DetailsJohn Menard
6/21/01 16:20:14 JCM - activity updated through activity BLDA022 from case BLD01-01054.
Routing - FIRE6/15/2001 6/19/2001 PASS
Routing - PLAN CHECK6/19/2001 6/19/2001  
Routing - PLAN CHECK5/23/2001 6/15/2001  
Plan Reviewer's activity  6/15/2001  
Inserted revised plan sheets A1.1 & L1.1 and routed to Fire. JCM
Plan resubmittals received  6/14/2001  
2 sets of a1.1 L1.1 routed to John M. KMM
Plan Review Completed(1st rev)  5/23/2001 FAIL
Routing - FIRE5/21/2001 5/23/2001 FAIL
ACCESS ISSUES; SIZE & TYPE OF SPRINKLER UNDERGROUND
Routing - PLAN CHECK5/14/2001 5/21/2001  
Plan Reviewer's activity  5/21/2001 PASS
Plans reviewed and approved as submitted with attached comment list. JCM
Routing - PLANNING5/2/2001 5/14/2001 FAIL
Approved under CUP01-00001 on 5/9/01 by DAA. Failed by TKW since the applicant needs to submit a phasing plan and show compliance with conditions of DRH00-105.
Routing Off Site - STRUCTURAL4/26/2001 5/10/2001 PASS
Contacted PDQ to take plans to outside eng. KMM Received a fax from the consulting structural engineer approving the structural plans as submitted. JCM
Routing - PUBLIC WORKS4/26/2001 5/2/2001 PASS
Plan resubmittals received  4/30/2001 DONE
Received six copies of revised C-1 & C-2. Put with plans. KMM
Plan routing begun/NEW & ADDTN  4/26/2001 HOLD
Requires stamped and signed Arch. sheets.
Plans ACCEPTED BY PLAN TECH  4/26/2001 HOLD
Requires 1. Stamped and signed Arch. sheets.
contacted Wes Steele of this need. He stated he would be in today to do so. KMM
Received Certificate of Value  4/25/2001 DONE
Application received  4/25/2001  
Recd Pcfee & Taken To Pln CK  4/25/2001 DONE