Case Summary (BLD) | | | 1/12/2016 | | DONE |
|
|
|
|
Fee Review-notes | 4/30/2001 | 4/30/2001 | 1/29/2002 | | DONE |
|
|
|
|
Permanent Occupancy | | 9/5/2001 | 9/5/2001 | | DONE |
|
|
|
|
Permanent occupancy | | | 9/5/2001 | | DONE |
|
|
|
Perm. Occ. Cert. #8812 issued 9-5-01 to Air Van North American.
|
FIRE-Final Inspection | 8/28/2001 | 8/28/2001 | 8/28/2001 | P | PASS |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 08/28/2001 at 07:34:09. Contact: ###-####. storage over 20 ft in two areas; will have down for structural inspector 8/28/2001 1:47:40 PM
|
BLD-Other | 8/28/2001 | 8/28/2001 | 8/28/2001 | P | FAIL |
Jim Storey
|
|
|
1. (Stairway rise and run) The rise of steps and stairs shall not be less than 4 inches nor more than 7 inches. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Except as permitted for circular, winding, and spiral stairways, the run shall not be less than 11 inches as measured horizontally between the vertical planes of the furthermost projection of adjacent treads or nosings. Stair treads shall be of uniform size and shape, except the largest tread run within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (1997 UBC 1003.3.3.3) Note the exception to tread and riser dimensions for private stairways and stairways to unoccupied roofs and. Also, note the exception to dimensions of risers adjoining a sloping public way.
|
FIRE-Final Inspection | 8/23/2001 | 8/23/2001 | 8/23/2001 | P | FAIL |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 08/23/2001 at 07:42:01. Contact: ###-####. exit blocked; storage height exceed 20 ft; extinguishers 8/23/2001 3:45:50 PM
|
BLD-Other | 8/23/2001 | 8/23/2001 | 8/23/2001 | P | FAIL |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 08/23/2001 at 07:43:41. Contact: ###-####. c/n on bld00955 aplies to this permit also. 8/23/2001 3:17:46 PM
|
Issue PAID IN FULL permit | | | 6/28/2001 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 6/19/2001 | | 6/20/2001 | | PASS |
Ron Hill
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 6/20/2001 | | PASS |
Ron Hill
|
|
|
|
Inspection Record Card- Bld | | | 6/20/2001 | | DONE |
|
|
|
|
Print Occupancy Form | | | 6/20/2001 | | DONE |
|
|
|
|
Telephone call | | | 6/20/2001 | | DONE |
|
|
|
left mess that permit is ready
|
Plan assigned to (R_H) | 6/4/2001 | | 6/20/2001 | | PASS |
|
|
|
6/20/2001 15:33:46 RMH - activity updated through activity BLDA022 from case BLD01-01115.
|
Plan Review Completed(1st rev) | | | 6/19/2001 | | FAIL |
|
|
|
|
Routing - FIRE | | | 6/19/2001 | | PASS |
|
|
|
|
Plan resubmittals received | | | 6/14/2001 | | |
|
|
|
1 COPY PLAN CHECK LETTER
2 REVISED SHEET A1.0, A2.0 TOOK TO RON HILL
|
Plan Reviewer's activity | | | 6/13/2001 | | DONE |
Ron Hill
|
|
|
Faxed and mailed requirements to the architect. Routed to fire Department for review.
|
Case Summary (BLD) | | | 6/13/2001 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 5/2/2001 | | 6/13/2001 | | FAIL |
Ron Hill
|
|
|
Faxed and Mailed requirements to the architect, route to fire department.
|
Plan assigned to (DRS) | 5/2/2001 | | 6/4/2001 | | DONE |
Dan Stuart
|
|
|
Reassigned to Ron Hill by M. Southard.
|
Plans ACCEPTED BY PLAN TECH | | | 5/2/2001 | | DONE |
|
|
|
|
Application received | | | 4/30/2001 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 4/30/2001 | | |
|
|
|
|