Permit Information
Permit NumberBLD01-01206
StatusFinaled
Name IDAHO SPECIALIZED TRANSPORTATION/ RACKS
Site Address 1287 W BOEING ST
Project Name 
Customer Number 
ePlanReviewNo
Description
*IDAH0 SPECIALIZED TRANSPORT - INTERLAKE BRAND, STEEL STORAGE RACKS* To assemble steel storage racks of 96" & 144" length and 42" deep, with 3 load level (4', 8', & 12') heights per the manufacture's material specifications and the structural engineering detailed assembly requirements. To locate as indicated on the architects plans along the east & south walls and anchor to the concrete floor per the engineered design using (1) - 5/8" Rawl Wedge Bolts per vertical leg of rack with a minimum of 2-1/2" embedment required. Per design, Special Inspection IS NOT required. All per approved plans, notes, attached plan review conditions & engineering. PC#01-399 / drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  6/27/2017 DONE
Case Summary (BLD)  1/12/2016 DONE
Case Summary (BLD)  1/12/2016 DONE
Fee Review-notes5/7/20015/7/20012/21/2003 DONE
BLD-Aging Inspection1/28/20031/28/20031/28/2003 PASS
DetailsJim Storey
final ok fire aproval achived. 1/28/2003 9:18:54 AM
DOC - Permit Finaled1/28/20031/28/20031/28/2003APASS
DetailsJim Storey
Finaled by inspector at 1/28/2003 9:18:57 AM
FIRE-Final Inspection8/23/20018/24/20018/24/2001APASS
DetailsJoe Tawney
Final Ok for certificate of completion 8/24/2001 12:34:15 PM
BLD-Other8/23/20018/24/20018/24/2001PCANC
DetailsJim Storey
Scheduled by a contractor via Hello! on 08/23/2001 at 16:21:51. Contact: ###-####.
BLD-Aging Inspection8/16/20018/16/20018/16/2001 FAIL
DetailsJim Storey
need fire owner joel will call for insp 5 day notice. 8/23/2001 3:34:39 PM
Routing - PLAN CHECK5/16/20015/16/20015/16/2001 PASS
New engineering received in response to plan review. Approved as noted and attached.
Plan assigned to (DRS)5/8/20015/8/20015/16/2001 PASS
DetailsDan Stuart
5/16/2001 08:41:40 DRS - activity updated through activity BLDA022 from case BLD01-01206.
Received Certificate of Value  5/16/2001  
Requested new certificate of value from tenant. Received update evaluation of $1,600.00 installation & $5,600.00 for rack cost (used) = $7,200.00 Total
PLANS/APPL TAKEN TO FRONT DESK  5/16/2001 PASS
Routing to permit desk to issue.
Inspection Record Card- Bld  5/16/2001 DONE
Print Occupancy Form  5/16/2001 DONE
Telephone call  5/16/2001 DONE
talked to joel to verify plans are ready
Issue PAID IN FULL permit  5/16/2001 DONE
Plan resubmittals received  5/15/2001 DONE
Received two copies of revised Structural Calculations for Rack Storage. Routed to Dan S. KMM
Routing - PLAN CHECK5/9/20015/9/20015/9/2001 FAIL
Incomplete and incorrect in formation submitted by architect and structural engineer. Did not receive any Interlake engineering design, specifications & loading tables for the racks; discussion with the tenant disclosed the racks are not new but used; racks are 8 foot in width for the most part as well as the 12 foot shown on plans; engineering reflects load reduction of 50% for seismic per section 2228 UBC but in one direction the four columns in a line are not met - reduction may not be allowed; size of base plate with spacing of connections need to verified against Table 3 of ER-5788 for possible reduction of anchor load resistance capabilities; etc. I have called and left message for the architect, Matt Rhees & Engineer, Darren Truchot with my concerns and will formulate a letter to them. Plans are on hold until re-submittals are received to answere concerns.
Telephone call  5/9/2001 DONE
Called Darren Truchot, Pinnale Engineering to see if he had engineering design specifications for Interlake racks showing load capabilities, column, beam & base plate dimensions & load capabilities; discuss the 50% reduction used for seismic design per section 2228 UBC; the load limits to be placed on the rack beams to comply with 2222.5, for each beam type (96" & 144") where he designed only for the 144" beam .
Telephone call  5/9/2001 DONE
Matt Rhees, Cole | Assoc. to review the plan layout submitted and to let him know the engineering submitted was incomplete and that I had called Darren Truchot.
Telephone call  5/9/2001 DONE
Call Joel Wood, manager of Idaho Specialized Transportation, Inc. to see if he had information on the new steel storage racks to be installed. I was told that they were not new but existing racks of a previous tenant and that moer of them were 8 feet in width than 12 feet. Joel also had somr rack information from the original rack owner and hed would dend this information to me.
Plans ACCEPTED BY PLAN TECH  5/8/2001 DONE
Application received  5/7/2001  
Recd Pcfee & Taken To Pln CK  5/7/2001