Permit Information
Permit NumberBLD01-01593
StatusFinaled
Name BOISE FACTORY OUTLETS (SHELL)
Site Address 6954 S EISENMAN RD
Project NameBOISE FACTORY OUTLET
Customer Number 
ePlanReviewNo
Description
(BOISE FACTORY OUTLETS - SHELL) This building is fire sprinklered for building area increase. To create a 7,631 square foot retail sales tenant space from a larger space. This is a shell permit. The tenant improvement is covered under BLD01-01677. A total of 6,046 square feet is devoted to retail sales. Work is to include a 1-hr tenant demising wall, interior nonbearing walls, 2 restrooms accessible to the disabled, an egress hallway, and suspended ceilings all per approved drawings and plan review conditions on file. Fire sprinkler heads shall be located per NFPA 13-1999 as regulated by the Fire Department. This permit shall not establish a Certificate of Occupancy. PC-0488-01 **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  10/20/2014 DONE
Letter of compliance  9/27/2001 DONE
Letter of Compliance #20892 issued 9-27-01.
BLD-Final9/25/20019/25/20019/25/2001PPASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 09/25/2001 at 07:35:42. Contact: ###-####. final ok card on site. 9/25/2001 3:07:05 PM
BLD-Framing/Rough-in8/30/20018/31/20018/31/2001AFAIL
DetailsJim Storey
###-#### greg this is a re -inspect wires not attched to framing east wall. 9/5/2001 9:16:06 AM
FIRE-Final Inspection8/30/20018/30/20018/30/2001PPASS
DetailsRick Jackson
gregg ###-####
FIRE-Conference8/29/20018/29/20018/29/2001PPART
DetailsRick Jackson
fire for conf-- greg ###-#### requirements for final; sprinklers, alarm and extinguisehrs 8/29/2001 11:02:08 AM
BLD-Framing/Rough-in8/28/20018/28/20018/28/2001PFAIL
DetailsJim Storey
1. (Suspended acoustical tile and lay-in panel ceilings) Metal suspension systems for acoustical tile and for lay-in panel ceilings shall comply with 1997 UBC Standard 25-2 (ASTM C635-69 & C636-69). (1997 UBC 2502.4) Note requirements for seismic bracing.) need wall primitor wires min 12 ga.
BLD-Framing/Rough-in8/1/20018/2/20018/2/2001AFAIL
DetailsJim Storey
r/i- late am????? greg- ###-#### no plan on site city approved. 8/2/2001 11:00:47 AM
BLD-Framing/Rough-in8/2/20018/2/20018/2/2001PPART
DetailsJim Storey
###-#### plans are on site need mech insp for cover ok to proceed upon approval from mech. insp. 8/2/2001 2:31:19 PM
Issue PAID IN FULL permit  7/17/2001 DONE
Plan Review Completed(1st rev)  7/16/2001 PASS
Routing - PLAN CHECK7/16/2001 7/16/2001 PASS
PLANS/APPL TAKEN TO FRONT DESK  7/16/2001 PASS
Inspection Record Card- Bld  7/16/2001 DONE
Print Occupancy Form  7/16/2001 DONE
Telephone call  7/16/2001 DONE
called ###-#### Jared Hobson permit ready for pickup
Routing - FIRE7/11/2001 7/16/2001 PASS
approved without written comment
Routing - PLAN CHECK6/18/2001 7/11/2001 PASS
Plan resubmittals received  7/11/2001 DONE
Received plan resubimittals from habitec Architecture, two sets of sheets A8.1 and A 8.2, forwarded same to Carl Westfall. 7/11/01 DAR
Plan Reviewer's activity  7/6/2001 PASS
UBC plan review started July 6, 2001 and finished July 9, 2001. The drawings were approved with conditions. See the conditions list.
Routing - PUBLIC WORKS6/15/2001 6/18/2001 PASS
Print Pending Permit.LaserJet4  6/15/2001  
Plans ACCEPTED BY PLAN TECH  6/15/2001 DONE
Wes is faxing arch/eng. record form. kmm
Received Certificate of Value  6/15/2001 DONE
Plan assigned to (CJW)6/15/2001 6/15/2001  
DetailsCarl Westfall
Application received  6/14/2001  
Recd Pcfee & Taken To Pln CK  6/14/2001