Permit Information
Permit NumberBLD01-01633
StatusFinaled
Name JOHNSTON CONDOMINIUM
Site Address 245 S CAPITOL BLVD Unit: 1604
Project NameGROVE HOTEL-16TH FLR
Customer Number 
ePlanReviewNo
Description
(JOHNSTON CONDO - 16TH & 17TH FLOORS) This building is required to be fire sprinklered because it is a high-rise. Two existing 2 level units are being combined into one unit. To create and remodel a 5,128 square foot, 2 level, residential condominium unit (2,491 square foot 2nd level and 2,637 square foot 1st level) on the 16th and 17th floors of an existing high-rise building. Selective demolition is also covered under this permit. Two openings in the 17th floor's post tensioned concrete slab will be filled in with new concrete floor slabs. Work is to include a cantilevered steel beam, steel floor deck, steel angles, epoxied bolts and rebar, concrete slabs, interior nonbearing walls, 2-hr fire-resistive protection, interior doors, interior windows, interior finishes, millwork, and a new exterior insulating window system all per approved drawings, engineering, and plan review conditions on file. The location of fire sprinkler heads shall comply with NFPA 13 as regulated by the Fire Department. A "DENSITY REDUCTION SURVEY", AS REQUIRED BY THE PUBLIC WORKS DEPARTMENT, SHALL BE COMPLETED AND THE NEW DEED RECORDED BEFORE A CERTIFICATE OF OCCUPANCY IS ISSUED FOR THIS TENANT SPACE. PC-0501-01 **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/31/20022/1/20022/1/2002APASS
DetailsCarl Dependahl
JIM ###-#### PLEASE CALL BEFORE AS YOU WILL NEED AN ACCESS CARD...shows pub wks on card...why? struct ok 2/1/2002 1:40:23 PM
Fee Review-notes6/18/20016/18/20012/1/2002 DONE
Letter of compliance  2/1/2002 DONE
Letter of Compliance #22141 issued 2-1-02.
FIRE-Final Inspection1/30/20021/31/20021/31/2002PPASS
DetailsRick Jackson
fire fn - jim ###-####
BLD-Aging Inspection12/31/200112/31/200112/31/2001 NR
DetailsCarl Dependahl
wip... 12/31/2001 1:25:34 PM
BLD-Framing/Rough-in10/26/200110/29/200110/29/2001APART
DetailsRuss Owen
###-#### JIM PLEASE CALL BEFORE GOING OUT . Need to install fire dampers at shaft indicated on plans 2nd floor , need to repair shaft at fire place, need to seal shaft at first floor at new duct with22 in rise, refridgerator box in corridor wall needs to be addressed may move location out of wall. Ok to cover walls at non affected areas.10/29/2001 12:31:09 PM floor 10/29/2001 12:31:14 PM 10/29/2001 12:32:02 PM o 10/29/2001 12:32:07 PM 10/29/2001 12:32:50 PM 10/29/2001 12:33:18 PM
BLD-Conference9/28/200110/1/200110/1/2001APASS
DetailsCarl Dependahl
for conf- chris ###-#### ..w Carl W. Rick J & Dave L. & contractor at site....add smoke-fire dampers as I MARKED ON PLANS. 10/1/2001 12:08:56 PM
BLD-Framing/Rough-in9/27/20019/28/20019/28/2001APART
DetailsCarl Dependahl
tibbetts- ###-#### 2 hr corridor ... firestopping at corridr wall at new entry ok, fireproofing complete at added beam, need mti report. need to sched conf re hvac & dampers at "shaft" 9/28/2001 4:34:37 PM
BLD-Framing/Rough-in9/11/20019/11/20019/11/2001PPART
DetailsCarl Dependahl
2hr shaft wall\\###-#### {not sure if fire or structural) cant'ed beam protection assy. 9/11/2001 4:30:46 PM
BLD-Framing/Rough-in8/16/20018/20/20018/20/2001APART
DetailsCarl Dependahl
r/i -for corridor-- chris -###-#### verbal c/n to complete firestops,add fasteners at gyp edges 8/20/2001 3:05:42 PM 8/20/2001 3:05:44 PM ok to rock;need clarify hvac/shaft penetrations 8/20/2001 3:06:14 PM
BLD-Conference8/9/20018/9/20018/9/2001PPASS
DetailsCarl Dependahl
Added by Inspector: 340 On 8/9/2001 5:15:33 PM w/ Chris, supt for Hedrick re wood w/type 1 bldg
Issue PAID IN FULL permit  7/20/2001 DONE
Inspection Record Card- Bld  7/6/2001 DONE
Print Occupancy Form  7/6/2001 DONE
Print Occupancy Form  7/6/2001  
Telephone call  7/6/2001 DONE
LEFT MESS THAT PERMIT IS READY
Plan Review Completed(1st rev)  7/5/2001 PASS
Routing - PLAN CHECK7/5/2001 7/5/2001 PASS
PLANS/APPL TAKEN TO FRONT DESK  7/5/2001 PASS
Plan assigned to (CJW)6/22/2001 7/5/2001 PASS
DetailsCarl Westfall
7/5/01 16:12:55 CJW - activity updated through activity BLDA022 from case BLD01-01633.
Routing - FIRE7/2/2001 7/5/2001 PASS
Routing - PLAN CHECK6/22/2001 7/2/2001 PASS
Plan Reviewer's activity  6/29/2001 PASS
UBC plan review started June 29, 2001 and finished July 2, 2001. The drawings were approved with conditions. See the conditions list.
Plan resubmittals received  6/26/2001 DONE
Received plan resubmittals from CSHQA, forwarded same to Carl Westfall. 6/26/01 DAR
Routing - PUBLIC WORKS6/22/2001 6/22/2001 PASS
Plans ACCEPTED BY PLAN TECH  6/19/2001 DONE
Application received  6/18/2001