Letter of compliance | | | 6/27/2002 | | DONE |
|
|
|
Letter of Compliance #22538 issued 6-27-02.
|
BLD-Final | 6/18/2002 | 6/18/2002 | 6/18/2002 | | DONE |
|
|
|
Final - ok/perm. occ.
|
Fee Review-notes | 7/2/2001 | 7/2/2001 | 1/29/2002 | | DONE |
|
|
|
org. values were to high baumgart faxed over a
|
BLD-Final | 12/28/2001 | 12/28/2001 | 12/28/2001 | P | PART |
Russ Owen
|
|
|
Ok for temporary oc, needs all other signatures on card for a perm oc ,note there are 3 permits on this job , carwash,builing/store and fuel island. 12/28/2001 3:16:02 PM
|
Temporary occupancy | | | 12/28/2001 | | PART |
|
|
|
Temp. Occ. Cert. #4694 issued 12-28-01 to Kick's 66 for the car wash bldg.
|
BLD-Final | 12/19/2001 | 12/20/2001 | 12/20/2001 | A | NR |
Russ Owen
|
|
|
###-####
|
BLD-Final | 12/18/2001 | 12/19/2001 | 12/19/2001 | P | NR |
Russ Owen
|
|
|
###-####. needs other req signatures 12/19/2001 4:29:35 PM
|
FIRE-Final Inspection | 12/17/2001 | 12/18/2001 | 12/18/2001 | A | PASS |
Troy Cobbley
|
|
|
life/safety finaled 12/18/2001 10:59:27 AM
|
BLD-Framing/Rough-in | 11/7/2001 | 11/7/2001 | 11/7/2001 | P | PASS |
Russ Owen
|
|
|
###-#### carwash roof. 11/7/2001 3:33:02 PM
|
BLD-Foundation | 10/31/2001 | 11/1/2001 | 11/1/2001 | A | CANC |
Russ Owen
|
|
|
###-#### justin
|
BLD-Concrete | 10/26/2001 | 10/26/2001 | 10/26/2001 | P | PASS |
Russ Owen
|
|
|
###-#### justin
|
BLD-Framing/Rough-in | 10/24/2001 | 10/25/2001 | 10/25/2001 | A | PART |
Russ Owen
|
|
|
justin ###-#### block wall. Has been poured appears ok. 10/25/2001 11:09:54 AM
|
BLD-Concrete | 10/25/2001 | 10/25/2001 | 10/25/2001 | P | PART |
Russ Owen
|
|
|
###-####. poured appears ok. Contractor notified not to pour any more w-o approval, This does not require special insp. 10/25/2001 4:43:27 PM
|
BLD-Framing/Rough-in | 10/24/2001 | 10/24/2001 | 10/24/2001 | P | NR |
Tom Arcoraci
|
|
|
###-#### steel
|
BLD-Foundation | 10/23/2001 | 10/23/2001 | 10/23/2001 | P | PART |
Tom Arcoraci
|
|
|
###-#### masonary wip ok 10/23/2001 3:00:59 PM
|
BLD-Foundation | 10/8/2001 | 10/9/2001 | 10/9/2001 | A | NR |
Russ Owen
|
|
|
###-#### justin
|
BLD-Footing | 9/13/2001 | 9/14/2001 | 9/14/2001 | P | PART |
Russ Owen
|
|
|
fd- justin ###-#### partial on carwash. 9/14/2001 4:55:11 PM
|
BLD-Footing | 9/11/2001 | 9/12/2001 | 9/12/2001 | A | NR |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 09/11/2001 at 15:46:22. Contact: ###-####.
|
BLD-Footing | 9/12/2001 | 9/12/2001 | 9/12/2001 | P | CANC |
Russ Owen
|
|
|
###-####
|
Print Occupancy Form | | | 9/10/2001 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/10/2001 | | DONE |
|
|
|
|
(F) Reprint permit | | | 9/7/2001 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 9/7/2001 | | DONE |
|
|
|
|
Print Occupancy Form | | | 9/7/2001 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 9/6/2001 | | |
|
|
|
|
Inspection Record Card- Bld | | | 9/4/2001 | | DONE |
|
|
|
|
Print Occupancy Form | | | 9/4/2001 | | DONE |
|
|
|
|
Telephone call | | | 9/4/2001 | | DONE |
|
|
|
left mess that permit is ready
|
Plan Reviewer's activity | | | 8/31/2001 | | PASS |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 8/31/2001 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/31/2001 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 8/31/2001 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 8/28/2001 | | 8/31/2001 | | DONE |
|
|
|
|
Plan assigned to (M_P) | 7/3/2001 | | 8/31/2001 | | PASS |
Mike Phillips
|
|
|
8/31/2001 13:19:10 M_P - activity updated through activity BLDA022 from case BLD01-01784.
|
Plan resubmittals received | | | 8/30/2001 | | DONE |
|
|
|
Received two copies of revised sheetA.3, A5, A.9, CW.3 Routed to Mike P. KMM
|
Plan Reviewer's activity | | | 8/29/2001 | | PEND |
|
|
|
Waiting for convenience store items to be completed prior to issuing permits.
|
Routing - FIRE | 8/23/2001 | | 8/28/2001 | | PASS |
|
|
|
|
Routing - PLUMBING | 8/20/2001 | | 8/22/2001 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 8/13/2001 | | 8/17/2001 | | HOLD |
|
|
|
Hold. Waiting for resubmittals from architect to respond to plan review corrections.
|
Plan resubmittals received | | | 8/17/2001 | | DONE |
|
|
|
Plans redrawn and resubmitted in their entirety to address all corrections and additional changes by architect. Forwarded to Mike Phillips.
|
Plan Review Completed(1st rev) | | | 8/13/2001 | | FAIL |
|
|
|
|
Routing - FIRE | 8/8/2001 | | 8/13/2001 | | FAIL |
|
|
|
hydrant flow, landscape obstrucing hydrant
|
Routing - PUBLIC WORKS | 8/7/2001 | | 8/8/2001 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 7/13/2001 | | 8/2/2001 | | FAIL |
|
|
|
Routing to fire.
|
Plan Reviewer's activity | | | 8/2/2001 | | FAIL |
|
|
|
Additional information required for further review.
|
Print Pending Permit.LaserJet4 | | | 8/2/2001 | | |
|
|
|
|
Routing - PUBLIC WORKS | 7/23/2001 | | 7/24/2001 | | FAIL |
|
|
|
Requires drainage plan revision per Brian Murphy. 7/24/01 DAR
|
Routing - PLUMBING | 7/10/2001 | | 7/13/2001 | | FAIL |
|
|
|
GREASE INTERCEPTOR VENT MUST BE LOCATED DOWNSTREAM OF DISCHARGE DIPTUBE, PROVIDE PLUMBING PLANS FOR THE CARWASH. WATER SERVICE LOCATION ON PAGE P.2 DOES NOT MATCH PAGE C.3, VERIFY AND REVISE, CARWASH ENTERANCE DRAIN MUST BE COVERED, IF INSTALLED, PER PRETREATMENT REQUIREMENTS, PROVIDE A FLOOR SINK FOR FILTERED WATER R.P., AND ANY OTHER EQUIPMENT ISOLATION R.P.s, USE INTERCEPTOR DETAIL ATTACHED FOR GREASE INTERCEPTOR, ADD ADDITIONAL VENT TO UPSTREAM COMPARTMENT, VENTED SEPARATLY THRU THE ROOF, FOR THE CARWASH INTERCEPTOR.
|
Routing - PLANNING | 7/9/2001 | | 7/10/2001 | | PASS |
|
|
|
Approved by SAR and TKW per CUP01-24 & DRH01-40
|
Routing - PUBLIC WORKS | 7/3/2001 | | 7/9/2001 | | FAIL |
|
|
|
brian m. failed, requires drainage plan revisions
|
Plan routing begun/NEW & ADDTN | | | 7/3/2001 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 7/3/2001 | | DONE |
|
|
|
|
Received Certificate of Value | | | 7/2/2001 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 7/2/2001 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 7/2/2001 | | DONE |
|
|
|
|
Application received | | | 7/2/2001 | | |
|
|
|
|