Information based on query as of Sunday, August 18, 2024.
Permit Information
Permit NumberBLD01-01834
StatusFinaled
Name WESTMINSTER HOMES
Site Address 3812 W QUAIL HEIGHTS CT
Project NameHILLSIDE
Customer Number 
ePlanReviewNo
Description
To construct a 3172 sq. ft. two story single family dwelling with a 992 sq. ft. finished basement, a 846 sq. ft. attached three car garage, a 75 sq. ft. covered entry way and concrete patios per approved plans, all engineering/red-lining and attached requirement lists. (1st floor 2448 sq. ft.)(2nd floor 722 sq. ft.) This lot is within a hillside area and is subject to the hillside ordinances. Class "A" roof system and defensible space will be required. Condition list is part of the approved plans. PC #504 DJO
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference3/28/20024/2/20024/2/2002APASS
DetailsTony Young
check landing on master br, cont. handrail 4/1/2002 1:10:37 PM
ok at this time. 4/2/2002 10:24:24 AM
DOC - Permit Finaled4/2/20024/2/20024/2/2002APASS
DetailsTony Young
Finaled by inspector at 4/2/2002 10:24:33 AM
BLD-Final3/28/20023/28/20023/28/2002PPASS
DetailsTony Young
fn insp- clyde- ###-####
BLD-Grading Inspection3/28/20023/28/20023/28/2002 PASS
DetailsRita DeYoung
FINAL GRADING AND DRAINAGE IS APPROVED
BLD-Final3/26/20023/27/20023/27/2002PFAIL
DetailsTony Young
CLIVE 870--9919
conf. only on final, no c/n, just a verbal punch list, not a formal inspection 3/27/2002 3:14:14 PM
BLD-Final3/26/20023/26/20023/26/2002PNR
DetailsTony Young
CLIVE ###-####
BLD-Aging Inspection1/7/20021/7/20021/7/2002 PART
DetailsTony Young
BLD-Energy code compliance11/5/200111/6/200111/6/2001APASS
DetailsTony Young
Scheduled by Inspector: 407 On 11/5/2001 4:51:56 PM
BLD-Energy code compliance11/5/200111/5/200111/5/2001PCANC
DetailsRuss Owen
###-#### george. 11/5/2001 4:54:52 PM rescheduled for am 11/6. unable to do. 11/5/2001 4:55:46 PM
BLD-Framing/Rough-in10/31/200111/1/200111/1/2001APASS
DetailsTony Young
###-####
BLD-Framing/Rough-in10/26/200110/29/200110/29/2001AFAIL
DetailsTony Young
###-#### GEORGE
c/n posted, no insulation 10/29/2001 10:50:33 AM
BLD-Framing/Rough-in10/10/200110/11/200110/11/2001ANR
DetailsTony Young
call framer ###-####
BLD-Framing/Rough-in10/11/200110/11/200110/11/2001PPART
DetailsTony Young
re-inspect shear ###-#### 10/11/2001 11:05:28 AM
ext. shear ok w/ corrections 10/11/2001 2:56:39 PM
BLD-Framing/Rough-in10/11/200110/11/200110/11/2001PPART
DetailsTony Young
Added by Inspector: 415 On 10/11/2001 3:37:03 PM ext. shear ok pending structural engineer report/approval on tall walls as built or fix
BLD-Framing/Rough-in10/9/200110/9/200110/9/2001PFAIL
DetailsTony Young
###-####--shear nail 10/9/2001 9:07:28 AM
c/n posted 10/10/2001 10:33:45 AM
BLD-Framing/Rough-in10/8/200110/8/200110/8/2001PFAIL
DetailsTony Young
###-#### SHEARNAIL
c/n posted 10/9/2001 9:05:53 AM
BLD-Foundation8/16/20018/16/20018/16/2001PPART
DetailsTony Young
Scheduled by a contractor via Hello! on 08/16/2001 at 10:02:13. Contact: ###-####.wip, ok, verbal correction 8/16/2001 2:18:19 PM
BLD-Footing8/15/20018/15/20018/15/2001PPART
DetailsTony Young
###-#### randy
house ftgs ok 8/15/2001 4:11:11 PM
BLD-Foundation7/27/20017/27/20017/27/2001PPART
DetailsTony Young
Michael ###-####
basement walls and garage walls ok w/ verbal corrections 7/27/2001 4:33:09 PM
BLD-Footing7/24/20017/25/20017/25/2001APART
DetailsTony Young
Scheduled by a contractor via Hello! on 07/24/2001 at 21:57:04. Contact: ###-####.basement ftgs ok and garage ftgs ok w/ verbal corrections///wip on all 7/25/2001 11:20:59 AM
BLD-Footing7/24/20017/24/20017/24/2001PCANC
DetailsTony Young
###-####
Issue PAID IN FULL permit  7/20/2001  
Plan assigned to (DJO)7/18/20017/18/20017/19/2001 PASS
DetailsDan Overy
7/19/2001 11:57:19 DJO - activity updated through activity BLDA022 from case BLD01-01834.
Case Summary (BLD)  7/19/2001 DONE
Plan Review Report  7/19/2001 DONE
PLANS/APPL TAKEN TO FRONT DESK  7/19/2001 DONE
Inspection Record Card- Bld  7/19/2001 DONE
Print Occupancy Form  7/19/2001 DONE
Telephone call  7/19/2001 DONE
talked to george
Plans ACCEPTED BY PLAN CHECK  7/18/2001  
Routing - PLANNING7/11/20017/11/20017/13/2001 PASS
Routing - PUBLIC WORKS GRADING7/9/20017/9/20017/11/2001 PASS
DetailsRita DeYoung
Approved as Category 3 with conditions of approval in letter attached to plans. took to terry records 7/9/2001/pe
Routing - PUBLIC WORKS7/9/20017/9/20017/11/2001 DONE
FEES PAID TO NORTHWEST BOISE SEWER DIST. LW/PE
Application received  7/9/2001  
Routing - PLAN CHECK7/13/20017/13/2001  PEND
Pending Assignment by DJO7/9/2001   PEND
DetailsDan Overy