DOC - L/C Approved | | | 9/9/2002 | | DONE |
|
|
|
LC approved for Carriage Crossing Shopping Center building #1 #22576
|
BLD-Final | 9/4/2002 | 9/5/2002 | 9/5/2002 | A | PASS |
Jim Storey
|
|
|
8:30; Phone #: ###-#### Internet Inspection Request from: Amy Lawson
|
Code Occupancy Approval | 7/1/2002 | 7/1/2002 | 7/1/2002 | P | PASS |
Wm. Michael Meloy
|
|
|
Passing as a shell construction with associated landscaping 7/1/2002 3:48:15 PM
|
FIRE-Final Inspection | 6/27/2002 | 6/28/2002 | 6/28/2002 | P | PASS |
Rick Jackson
|
|
|
fn fire- terry- ###-#### building 1 is okay; GC wanted building two but paved access won't be in until late July - won't approve until paved access is complete 6/28/2002 2:19:29 PM
|
BLD-Final | 6/11/2002 | 6/11/2002 | 6/11/2002 | P | NR |
Jim Storey
|
|
|
TERRY ###-####
|
BLD-Framing/Rough-in | 4/29/2002 | 4/30/2002 | 4/30/2002 | A | PASS |
Jim Storey
|
|
|
terry- ###-#### re-insp fr
|
BLD-Framing/Rough-in | 4/26/2002 | 4/29/2002 | 4/29/2002 | A | FAIL |
Jim Storey
|
|
|
###-#### MIKE truss engineering not complet for bracing/hanger nailling / top chord bracing/scabs at dtag truss with naill patren. 4/29/2002 10:33:19 AM
|
BLD-Framing/Rough-in | 4/16/2002 | 4/17/2002 | 4/17/2002 | P | PASS |
Jim Storey
|
|
|
shear wall--mike ###-#### exterior wall nailling ok for cover. 4/17/2002 3:03:14 PM
|
BLD-Framing/Rough-in | 4/11/2002 | 4/12/2002 | 4/12/2002 | P | PASS |
Dave Hannah
|
|
|
roof nailing\\###-####
|
BLD-Footing | 2/27/2002 | 2/28/2002 | 2/28/2002 | A | PASS |
Tom Arcoraci
|
|
|
MIKE ###-####
|
BLD-Footing | 2/26/2002 | 2/27/2002 | 2/27/2002 | A | NR |
Tom Arcoraci
|
|
|
MIKE ###-####
|
BLD-Footing | 2/27/2002 | 2/27/2002 | 2/27/2002 | P | PASS |
Tom Arcoraci
|
|
|
Scheduled by Inspector: 408 On 2/27/2002 10:37:32 AM mike ###-####
|
BLD-Footing | 2/25/2002 | 2/26/2002 | 2/26/2002 | P | PASS |
Jim Storey
|
|
|
MIKE ###-#### wall rebar ok 2/26/2002 2:28:26 PM
|
Plan resubmittals received | | | 12/27/2001 | | DONE |
|
|
|
Received five copies of revised sheets A2.0 A2.3, A2.4, and three copies of revised calcs. and one copy of response letter. Routed to John M. kmm
|
(F) Reprint permit | | | 12/26/2001 | | |
|
|
|
|
Issue & PRINT permit | | | 12/24/2001 | | DONE |
|
|
|
|
Print Occupancy Form | | | 12/21/2001 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 12/21/2001 | | |
|
|
|
|
Inspection Record Card- Bld | | | 12/21/2001 | | DONE |
|
|
|
|
Telephone call | | | 12/21/2001 | | DONE |
|
|
|
permit ready and need ACHD
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/20/2001 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 12/17/2001 | | 12/20/2001 | | PASS |
|
|
|
|
Plan assigned to (JCM) | 10/17/2001 | | 12/20/2001 | | PASS |
John Menard
|
|
|
12/20/2001 15:22:02 JCM - activity updated through activity BLDA022 from case BLD01-02154.
|
Override - Parcel Holds | | | 12/18/2001 | | |
|
|
|
|
Routing - PLANNING Land Div | 12/17/2001 | | 12/18/2001 | | PASS |
|
|
|
Land division ok. Routed back to Plan Review. (blc)
|
Routing - PUBLIC WORKS | 12/14/2001 | | 12/17/2001 | | PASS |
|
|
|
|
Override - Parcel Holds | | | 12/17/2001 | | |
|
|
|
|
Routing - PLANNING Land Div | 12/12/2001 | | 12/14/2001 | | FAIL |
|
|
|
(Waiting for new parcel #s from Assessor's office.) Routed to Public Works. (blc)
|
Override - Parcel Holds | | | 12/12/2001 | | |
|
|
|
|
Routing - PLAN CHECK | 11/23/2001 | | 12/12/2001 | | |
|
|
|
|
Plan resubmittals received | | | 12/11/2001 | | DONE |
|
|
|
Received two sets of resubmittal sheets A4.0, A4.1, A4.5, A10.0, WITH TRANSMITTAL LETTER. Routed to John Menard.
|
Plan resubmittals received | | | 12/11/2001 | | DONE |
|
|
|
Received five sets of resubmittal sheets A2.3, A2.4, A2.7, A2.8, A4.4, A4.5, A8.0, A9.1, A10.0, THREE COPIES OF CALCULATIONS, and cover letter. Routed to John Menard.
|
Plan resubmittals received | | | 12/10/2001 | | DONE |
|
|
|
Received one set of resubmittal sheets A2.0, A2.1, A4.2, A4.4, A8.0 WITH revision dated 11/26/01. Received four sets of plan resubmittal sheet A8.0 with cover letter. Routed to John Menard.
|
Plan resubmittals requested | | | 12/4/2001 | | |
|
|
|
Faxed a copy of the structural review comment list to John Price requesting additional structural revisions. JCM
|
Routing Off Site - STRUCTURAL | 11/13/2001 | | 12/4/2001 | | FAIL |
|
|
|
Contacted PDQ to take plans to outside eng. Received a comment list from the consulting structural engineer requesting revisions. JCM
|
Plan Reviewer's activity | | | 12/3/2001 | | PASS |
|
|
|
Plan resubmittals reviewed and approved as submitted with attached comment list. JCM
|
Plan resubmittals received | | | 11/28/2001 | | DONE |
|
|
|
Received three sets of resubmittal sheets A2.0, A2.1, A4.2, A4.4, A8.0, and response letter. Routed to John Menard.
|
Routing - FIRE | 11/20/2001 | | 11/21/2001 | | PASS |
|
|
|
approved without written comment
|
Routing - PLAN CHECK | 11/15/2001 | | 11/20/2001 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 11/19/2001 | | |
|
|
|
Sent the architect of record a copy of the comment list requesting revisions. JCM
|
Routing - PLUMBING | 11/9/2001 | | 11/15/2001 | | PASS |
|
|
|
|
Plan resubmittals received | | | 11/13/2001 | | DONE |
|
|
|
Received three sets of resubmittal sheets A4.0, A4.1, A4.5, A10.0, three sets of supplemental calculations, and response letter. Routed to John Menard.
|
Routing - PLANNING | 11/5/2001 | | 11/9/2001 | | PASS |
|
|
|
Approved as per CUP01-00019 and per DRH01-57.
|
Routing - PUBLIC WORKS | 10/18/2001 | | 11/5/2001 | | FAIL |
|
|
|
Subdivision not recorded but expects subdivision should be recorded in the next week or so per John Price.
|
Override - Parcel Holds | | | 10/18/2001 | | |
|
|
|
|
Routing - PLANNING Land Div | 10/17/2001 | | 10/18/2001 | | FAIL |
|
|
|
Surrey Crossing Subdivision not yet recorded. 10/18/01
|
Plan routing begun/NEW & ADDTN | | | 10/17/2001 | | DONE |
|
|
|
|
CHANGE STATUS TO (R) | | | 10/17/2001 | | DONE |
|
|
|
per Kathy M.
|
Plans ACCEPTED BY PLAN TECH | | | 10/17/2001 | | DONE |
|
|
|
|
Application received | | | 10/12/2001 | | |
|
|
|
|
Fee Review-notes | 8/7/2001 | 8/7/2001 | 9/26/2001 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 8/27/2001 | | |
|
|
|
Faxed a copy of the structural engineer's comment list the architect of record. JCM
|
Plan assigned to (JCM) | 8/7/2001 | | 8/24/2001 | | VOID |
John Menard
|
|
|
Permit application pulled because subdivision is not recorded. JCM
|
VOIDED CHANGE STATUS | | | 8/24/2001 | | DONE |
|
|
|
per Marlene void
|
Routing - PLANNING | 8/14/2001 | | 8/15/2001 | | PEND |
|
|
|
Approved as per CUP01-00019. Design Review approval required.
|
Routing - PUBLIC WORKS | 8/8/2001 | | 8/9/2001 | | FAIL |
|
|
|
Subdivision not recorded per April Miller. 8/9/01 DAR
|
Application received | | | 8/7/2001 | | |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 8/7/2001 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 8/7/2001 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 8/7/2001 | | DONE |
|
|
|
|
Routing Off Site - STRUCTURAL | 10/17/2001 | | | | |
|
|
|
Contacted PDQ to take plans to outside eng. KMM
|