Permit Information
Permit NumberBLD01-02286
StatusFinaled
Name HOGI YOGI
Site Address 997 N MILWAUKEE ST
Project Name 
Customer Number 
ePlanReviewNo
Description
*HOGI YOGI - TYPE I GREASE HOOD* To install a Type I Grease Hood and Exhaust Duct System with Firemaster Duct Wrap, per ER-4975, as the required 1-hour minimum shaft protection; installation of Ansol R-102 Wet Chemical Fire Supression System in the hood & duct per UFC; and connection of the hood alarm system into the existing tenant space, strip mall complex per UFC. All as noted on and attached to the approved plans. NOTE: The scope of work under this permit needs to be completed and approved before or at the same time as reactivation & final approval of remodel permit BLD00-02504. Both permits require issuance of a separate "Letter of Completion / Compliance". NOTE: Building is fully sprinklered. Sprinklers used for allowable area increase. PC#01-692/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  2/12/2016 DONE
Fee Review-notes8/21/20018/21/20017/5/2002 DONE
BLD-Final4/8/20024/9/20024/9/2002APASS
DetailsRuss Owen
Scott, ###-#### Ok for a perm oc , providing all signatures are on job card. 4/9/2002 11:03:42 AM
Letter of compliance  4/9/2002 DONE
Letter of Compliance #22325 issued 4-9-02.
FIRE-Final Inspection4/3/20024/3/20024/3/2002PPASS
DetailsTroy Cobbley
fire life/safety finaled. fire alarm finaled.
CHANGE STATUS TO (ISS)  4/3/2002  
BLD-Final1/3/20021/4/20021/4/2002PPART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 01/03/2002 at 12:11:20. Contact: ###-####.Went over requirements for final need health dpt and fire/life safety, Mec and Bld can be done at same time . 1/4/2002 4:50:06 PM
Print Occupancy Form  1/3/2002 DONE
BLD-Aging Inspection11/28/200111/28/200111/28/2001 PART
DetailsRuss Owen
BLD-Conference9/4/20019/5/20019/5/2001APART
DetailsRuss Owen
steve- ###-#### for conf. owner does not want to install fire masters duct wrap as per plan, 2 wraps equals 2 hour installer wanted to install 1 wrap ,but no listed assemby exist,told him to find one or due 2 wraps. 9/5/2001 12:41:42 PM
Issue PAID IN FULL permit  9/4/2001 DONE
Routing - FIRE8/24/20018/28/20018/31/2001 DONE
DetailsBill Alexander
Plan assigned to (DRS)8/24/20018/24/20018/31/2001 PASS
DetailsDan Stuart
8/31/2001 11:58:28 DRS - activity updated through activity BLDA022 from case BLD01-02286.
Plan assigned to (MYS)8/21/20018/21/20018/31/2001 PASS
DetailsMarlene Southard
8/31/2001 11:58:28 DRS - activity updated through activity BLDA022 from case BLD01-02286.
Plan Review Completed(1st rev)  8/31/2001 DONE
Routing - PLAN CHECK8/31/2001 8/31/2001 PASS
Approved as noted on plans and plan review conditions and evaluation report ER4975, attached as part of the approved plans.
PLANS/APPL TAKEN TO FRONT DESK  8/31/2001 PASS
Routing to permit desk for issuance.
Inspection Record Card- Bld  8/31/2001 DONE
Print Occupancy Form  8/31/2001 DONE
Telephone call  8/31/2001 DONE
Routing - PLAN CHECK8/24/20018/24/20018/24/2001 PEND
Approved as noted and attached. Routing to fire code analyst for review and comment.
Meeting  8/22/2001  
Met with Steve Williams to review plans for Type I Grease Hood system for Hogi Yogi. Reviewed requirements for use of Firemaster Duct Wrap, ER-4975, requires speific double wrap with specific desnity and specific application and that this is what the inspector will inspect by. The hood needs to comply with the UMC for installation requirements & construction materials and the UFC for the fire supression system and connection to alarm system as required. Plans submitted to permit desk to pay plan review fee's and receive a BLD number.
Application received  8/21/2001  
Recd Pcfee & Taken To Pln CK  8/21/2001 DONE