Columbia Village Pump House * To construct a 425 sq. ft. pump house to cover an existing water pump. All work to be per the approved plans and attached engineering; conditions and notes attached.. Additional value and seperate mechanical permit required to install optional air handler. PC#754-01 pep
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/14/20033/21/20033/21/2003APASS
DetailsDave Hannah
follow up to 5 day notice pass ok for c.c 3/21/2003 9:45:11 AM
DOC - Permit Finaled3/21/20033/21/20033/21/2003APASS
DetailsDave Hannah
Finaled by inspector at 3/21/2003 9:45:29 AM
BLD-Aging Inspection3/11/20033/12/20033/12/2003AFAIL
DetailsJim Storey
waiting for follow up from dave mortsen job super.no action form phone call earler in week. 5 day notice posted on site no one around. p paine will recieve 5 day notice for on file copy. clone insp for 25 day notice insp. 3/14/2003 10:03:05 AM
BLD-Aging Inspection3/11/20033/11/20033/11/2003 PART
DetailsJim Storey
dave with mortsen said he would have the job super call me to follow up with insp and provide aproved plan. 3/11/2003 5:04:53 PM
BLD-Framing/Rough-in1/29/20021/29/20021/29/2002APASS
DetailsSteven Webb
Scheduled by a contractor via Hello! on 01/29/2002 at 07:03:49. Contact: ###-####. ok to insulate---fire damper needed in 1-hr fire wall prior to passing at final. 1/29/2002 8:52:18 AM
BLD-Energy code compliance1/29/20021/29/20021/29/2002PPASS
DetailsSteven Webb
Scheduled by a contractor via Hello! on 01/29/2002 at 07:04:54. Contact: ###-####. Insulation verified in building BUT per Table 5-A of 97 UBC opening IS NOT allowed (even with damper) on a S-2-type with in 5 feet even if protected. 1/29/2002 1:49:30 PM
BLD-Framing/Rough-in1/22/20021/25/20021/25/2002PFAIL
DetailsSteven Webb
Scheduled by a contractor via Hello! on 01/22/2002 at 14:55:55. Contact: ###-####. 30"' X 30" supply air cannot be in 1-Hour opening unless smoke and fire damper is installed with an equi. fire rating. Relocation outside the 1-Hr wall is also an option. 1/25/2002 2:26:41 PM
BLD-Wall cover12/12/200112/12/200112/12/2001PPASS
DetailsSteven Webb
Scheduled by a contractor via Hello! on 12/12/2001 at 10:23:06. Contact: ###-####. shear 12/12/2001 3:00:54 PM
BLD-Foundation11/26/200111/26/200111/26/2001PPART
DetailsSteven Webb
JACK ###-#### house wip--garage not ready 11/26/2001 2:34:50 PM
BLD-Footing11/20/200111/20/200111/20/2001PPASS
DetailsSteven Webb
Engineering recieved from Keith Jones--footing per his engineering. 11/20/2001 1:16:30 PM
BLD-Footing11/8/200111/9/200111/9/2001AFAIL
DetailsSteven Webb
###-#### JACK Electrical conduit which run through footing are not per as the approved plans indicate. Contractor to re-locate conduit which agrees with plans or modifiy plans to eliminate conduit positioned in footings. Do not pour. 11/9/2001 11:38:39 AM
BLD-Footing11/6/200111/7/200111/7/2001APART
DetailsSteven Webb
Scheduled by a contractor via Hello! on 11/06/2001 at 19:25:01. Contact: ###-####. Contractor to conference with electrical inspector -- will call for re-inspection. 11/7/2001 11:12:50 AM
BLD-Footing11/2/200111/5/200111/5/2001ADONE
DetailsSteven Webb
###-#### JACK Conference not footing--reviewed approved plans ok to modify to concrete as long as a min. of 12" footer and 6" stem wall is obtained. 11/5/2001 10:53:10 AM
(F) Reprint permit  10/26/2001 DONE
Issue PAID IN FULL permit  10/25/2001 DONE
Plan assigned to (PEP)9/20/2001 10/24/2001 PASS
DetailsPerry Paine
10/24/2001 13:42:22 PEP - activity updated through activity BLDA022 from case BLD01-02562.
Plan resubmittals received  10/24/2001 DONE
Received two copies of revised sheets SP, A1 and A2. One copy of cover letter and two copies of struc. calculations. Routed to Perry Paine. kmm
Print Pending Permit.LaserJet4  10/24/2001 DONE
PLANS/APPL TAKEN TO FRONT DESK  10/24/2001 DONE
Inspection Record Card- Bld  10/24/2001 DONE
Print Occupancy Form  10/24/2001 DONE
Telephone call  10/24/2001 DONE
permit ready
Plan Review Report  10/16/2001 DONE
Plan resubmittals requested  10/16/2001  
faxed plan review report to architect @ ###-####
Routing - FIRE10/16/2001 10/16/2001 PASS
approved without written comment
Routing - PLANNING9/20/2001 10/16/2001 PASS
Plan routing begun/NEW & ADDTN  9/20/2001 DONE
Routing - PUBLIC WORKS9/20/2001 9/20/2001 PASS
Plans ACCEPTED BY PLAN TECH  9/20/2001 DONE
First Notice9/19/20019/19/20019/19/2001 DONE
Received Certificate of Value  9/19/2001 DONE
<$25,000
Application received  9/19/2001  
Recd Pcfee & Taken To Pln CK  9/19/2001 DONE
Routing - PLAN CHECK10/16/2001