Fee Review-notes | 7/14/2003 | 7/14/2003 | 7/14/2003 | | DONE |
|
|
|
Additional values from subcontractors.
|
Permanent Occupancy | | 6/27/2002 | 6/27/2002 | | DONE |
|
|
|
|
BLD-Final | 6/27/2002 | 6/27/2002 | 6/27/2002 | P | PASS |
Carl Dependahl
|
|
|
rec'd stamped eng'g... & eifs certificates ok 6/27/2002 2:12:54 PM
|
Permanent occupancy | | | 6/27/2002 | | DONE |
|
|
|
Perm. Occ. Cert. #9225 issued 6-27-02 to Capital City Family Medicine.
|
BLD-Final | 6/26/2002 | 6/26/2002 | 6/26/2002 | P | FAIL |
Carl Dependahl
|
|
|
Rob..ENG'G APPROVAL LETTER REQ'S STAMP...SHOULD NOTE CONFIGURATION PER DESIGN...NOT JUST WELDS. 6/26/2002 12:33:56 PM
|
BLD-Final | 6/20/2002 | 6/21/2002 | 6/21/2002 | A | NR |
Carl Dependahl
|
|
|
###-#### ROB keep c/n 6/21/2002 3:12:21 PM
|
BLD-Conference | 6/21/2002 | 6/21/2002 | 6/21/2002 | P | PASS |
Carl Dependahl
|
|
|
8414712 ;keep c/n...need eifs install certs per listing...weep screeds???6/21/2002 3:32:25 PM 6/21/2002 3:33:23 PM
|
BLD-Conference | 6/17/2002 | 6/18/2002 | 6/18/2002 | A | FAIL |
Carl Dependahl
|
|
|
keep c/n; spec insp report inadequate...need eng's ok; EIFS doc's incomplete, install chain barrier at bsmt stair at north enclosure. keep c/n. 6/18/2002 10:59:37 AM
|
BLD-Conference | 6/17/2002 | 6/17/2002 | 6/17/2002 | P | CANC |
Carl Dependahl
|
|
|
rob- ###-#### for conf
|
BLD-Conference | 6/17/2002 | 6/17/2002 | 6/17/2002 | A | NR |
Carl Dependahl
|
|
|
|
BLD-Conference | 6/12/2002 | 6/12/2002 | 6/12/2002 | P | NR |
Carl Dependahl
|
|
|
ROB ###-#### PLEASE CALL 15 MIN BEFORE GOING OUT AS ROB IS AT B. S. U . recall ...need all eifs specs/certifications.... 6/12/2002 4:10:53 PM
|
BLD-Final | 6/4/2002 | 6/5/2002 | 6/5/2002 | A | NR |
Carl Dependahl
|
|
|
awaiting eifs report 6/5/2002 10:34:05 AM
|
BLD-Conference | 6/4/2002 | 6/4/2002 | 6/4/2002 | A | PASS |
Carl Dependahl
|
|
|
w/ Guho supt re bsmt barrier...ok to use chain & sign if single gate is obstruction to north exit path per GS. keep c/n, need eng's ok re beams...eifs certification/specs
|
BLD-Final | 5/28/2002 | 5/29/2002 | 5/29/2002 | A | CANC |
Carl Dependahl
|
|
|
###-#### called reschedule 5/29/2002 11:22:10 AM
|
BLD-Final | 5/29/2002 | 5/29/2002 | 5/29/2002 | P | FAIL |
Carl Dependahl
|
|
|
8414712 need efis certs, full eng's' spec insp reports 5/29/2002 4:48:24 PM
|
Fee Review-notes | 12/7/2001 | 12/7/2001 | 5/23/2002 | | DONE |
|
|
|
|
FIRE-Final Inspection | 5/21/2002 | 5/21/2002 | 5/21/2002 | P | PASS |
Rick Jackson
|
|
|
ROB ###-####
|
BLD-Final | 5/13/2002 | 5/14/2002 | 5/14/2002 | A | FAIL |
Carl Dependahl
|
|
|
###-#### rob rec'd partial spec.insp report, efis listings...keep c/n...complete other items; OK for t/o only. 5/14/2002 11:39:25 AM
|
Temporary occupancy | | | 5/14/2002 | | DONE |
|
|
|
Temp. Occ. Cert. #4808 issued 5-14-02 to Capital City Family Medicine.
|
FIRE-Final Inspection | 5/13/2002 | 5/13/2002 | 5/13/2002 | P | PASS |
Rick Jackson
|
|
|
ROB ###-####
|
BLD-Final | 5/13/2002 | 5/13/2002 | 5/13/2002 | P | FAIL |
Carl Dependahl
|
|
|
ROB ###-#### c/n other finals, efis listing & install ( verify support at ext infill wall...weep screeds, ec.) 1hr stair enclosure, bsmt barrier gate; Need eng's/spec. insp reports. recall. 5/13/2002 4:19:21 PM
|
BLD-Final | 5/10/2002 | 5/10/2002 | 5/10/2002 | P | NR |
Carl Dependahl
|
|
|
###-####...neeed fire, efis listing, etc..no further insp. 5/10/2002 4:24:40 PM
|
FIRE-Final Inspection | 5/10/2002 | 5/10/2002 | 5/10/2002 | P | FAIL |
Rick Jackson
|
|
|
###-#### elevator recall not working; need alarm plans; door hardware at main exit; door closures on stair enclosures; 5/10/2002 4:20:19 PM
|
FIRE-Alarm Testing | 5/10/2002 | 5/10/2002 | 5/10/2002 | P | FAIL |
Rick Jackson
|
|
|
###-#### need alarm plans 5/10/2002 4:20:40 PM
|
FIRE-Final Inspection | 5/9/2002 | 5/9/2002 | 5/9/2002 | P | FAIL |
Rick Jackson
|
|
|
rob ###-#### door hardware at main exit; alarms not ready; sprinkler escutcheons; FACP and sprinkler control signs on doors; 5/9/2002 4:13:59 PM
|
FIRE-Sprinkler Rough-in | 5/3/2002 | 5/3/2002 | 5/3/2002 | A | PASS |
Rick Jackson
|
|
|
Added by Inspector: 409 On 5/3/2002 8:12:34 AM okay to cover
|
BLD-Framing/Rough-in | 4/30/2002 | 5/1/2002 | 5/1/2002 | A | PART |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 04/30/2002 at 16:56:58. Contact: ###-####. add spreaders at grid...ok to tile pend elec/hvac 5/1/2002 2:08:23 PM
|
BLD-Framing/Rough-in | 4/26/2002 | 4/26/2002 | 4/26/2002 | A | PART |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 04/26/2002 at 07:07:17. Contact: ###-####. ext canopy ok to cover; show efis listings 4/26/2002 2:01:56 PM
|
BLD-Framing/Rough-in | 4/22/2002 | 4/23/2002 | 4/23/2002 | A | FAIL |
Carl Dependahl
|
|
|
###-#### keep c/n, add blocks at canopy., chk stair enclosures...shaft not req'd at riser per rick j. 4/23/2002 12:21:57 PM
|
BLD-Framing/Rough-in | 4/22/2002 | 4/22/2002 | 4/22/2002 | P | FAIL |
Carl Dependahl
|
|
|
fr insp- ###-####- rob ...c.n canopy , grid clg, firestops, recall 4/22/2002 3:10:42 PM 4/22/2002 3:14:52 PM
|
Plan resubmittals received | | | 4/1/2002 | | DONE |
|
|
|
Received two copies of revised sheet A1.1. Approved by Sarah Schafer 4/1/02. Put one copy with plans and second copy to site via Billy English. kmm
|
BLD-Foundation | 3/15/2002 | 3/15/2002 | 3/15/2002 | P | PART |
Carl Dependahl
|
|
|
found rob ###-#### , upper lift at masonry cols ok 3/15/2002 1:31:56 PM
|
BLD-Foundation | 3/14/2002 | 3/14/2002 | 3/14/2002 | P | PART |
Carl Dependahl
|
|
|
found rob ###-####
|
BLD-Foundation | 3/13/2002 | 3/13/2002 | 3/13/2002 | P | PART |
Carl Dependahl
|
|
|
found rob ###-#### masonry lift ok; wip on stair enclosures 3/13/2002 4:15:31 PM
|
BLD-Foundation | 3/12/2002 | 3/12/2002 | 3/12/2002 | P | PART |
Carl Dependahl
|
|
|
found rob- ###-#### , masonry cols, bsmt col ftgs ok 3/12/2002 2:35:06 PM
|
BLD-Conference | 3/8/2002 | 3/11/2002 | 3/11/2002 | A | PART |
Jim Storey
|
|
|
###-#### ROB grout ok under steel colums. 3/11/2002 1:56:40 PM
|
BLD-Conference | 3/11/2002 | 3/11/2002 | 3/11/2002 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 3/11/2002 11:25:55 AM w/ bldr re stair framing...provide 1hr detail
|
BLD-Framing/Rough-in | 3/4/2002 | 3/4/2002 | 3/4/2002 | P | PASS |
Tom Arcoraci
|
|
|
###-#### ROB 1st floor ok for cover 3/4/2002 2:29:27 PM
|
BLD-Footing | 2/27/2002 | 2/28/2002 | 2/28/2002 | P | PART |
Carl Dependahl
|
|
|
Scheduled by a contractor via Hello! on 02/27/2002 at 17:18:37. Contact: ###-####...1st lift cols. at entry ok. 2/28/2002 5:30:05 PM
|
BLD-Footing | 2/20/2002 | 2/21/2002 | 2/21/2002 | A | PART |
Carl Dependahl
|
|
|
ROB ###-####
|
BLD-Conference | 2/7/2002 | 2/7/2002 | 2/7/2002 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 2/7/2002 11:45:37 AM w/ Guho supt...widen stairs as req'd in plan notes
|
BLD-Conference | 2/6/2002 | 2/6/2002 | 2/6/2002 | P | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 2/6/2002 12:14:57 PM w/ GS & Bob onsite...re stair width, install at 44"
|
BLD-Conference | 2/4/2002 | 2/4/2002 | 2/4/2002 | P | PASS |
Carl Dependahl
|
|
|
###-####; w/ arch. Billy English & bldr, re-calc occ. load & submit request for use of 36" stairs where > 50 occupants per UBC 1003. 2/4/2002 2:35:29 PM
|
Telephone call | | | 1/25/2002 | | DONE |
|
|
|
left mess for billy english that permit is ready-also need a.c.h.d./mls
|
Issue PAID IN FULL permit | | | 1/25/2002 | | DONE |
|
|
|
|
Routing - PLANNING | 1/23/2002 | | 1/24/2002 | | |
|
|
|
Failed. The revised plan showing the 5% landscaping has not been incorporated into the building set.
|
Routing - PLAN CHECK | 1/24/2002 | | 1/24/2002 | | PASS |
|
|
|
|
Plan resubmittals received | | | 1/24/2002 | | DONE |
|
|
|
Received two copies of revised sheets A1.1, A1.2, one copy of cover letter. Routed to Carl W. kmm
|
Routing - PLANNING | 1/24/2002 | | 1/24/2002 | | PASS |
|
|
|
Approved per DRH01-00205.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 1/24/2002 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 1/24/2002 | | DONE |
|
|
|
|
Print Occupancy Form | | | 1/24/2002 | | DONE |
|
|
|
|
Plan assigned to (CJW) | 12/11/2001 | | 1/24/2002 | | PASS |
Carl Westfall
|
|
|
1/24/2002 14:19:28 CJW - activity updated through activity BLDA022 from case BLD01-03156.
|
Routing - PLAN CHECK | 1/18/2002 | | 1/23/2002 | | PASS |
|
|
|
Drawings approved, with conditions, after 2nd resubmittal review.
|
Plan resubmittals received | | | 1/22/2002 | | DONE |
|
|
|
Received two sets of resubmittal sheets A2.1, A5.1, A5.2, A5.3, A5.4, A6.1, A6.2, (2) SETS OF STRUCTURAL CALCULATIONS, AND COVER LETTER. ROUTED TO CARL WESTFALL.
|
Routing - PLAN CHECK | 1/2/2002 | | 1/17/2002 | | |
|
|
|
Failed 2nd UBC plan review. January 14, 2002 resubmittal reviewed January 17, 2002. Resubmitted drawings were required from the architect. See the conditions list.
|
Routing - PLANNING | 1/17/2002 | | 1/17/2002 | | |
|
|
|
Failed. The change in parking layout does not incorporate the 5% landscape requirement. Applicant has been notified.
|
Plan resubmittals received | | | 1/15/2002 | | DONE |
|
|
|
Received two copies of revised sheets A1.1 and A1.2, one copy of cover letter. routed to Carl W. kmm
|
Plan resubmittals received | | | 1/14/2002 | | DONE |
|
|
|
Reeived two copies of A1.2 and three copies of revised sheets A0.0, A1.1, A1.2, A2.0,, A2.1, A2.2, A3.1, A4.1, A5.1, A5.2, A5.3, A5.4, A6.1, A6.2, A7.1, M1.0, M2.0, M3.0, M3.1, M4.0, FP1.0, Routed to Carl W. kmm
|
Routing - FIRE | 12/31/2001 | | 1/2/2002 | | PASS |
|
|
|
|
Plan Review Completed(1st rev) | | | 1/2/2002 | | |
|
|
|
Failed first UBC and Planning review.
|
Routing - PLAN CHECK | 12/19/2001 | | 12/31/2001 | | |
|
|
|
Failed first UBC review. UBC plan review started December 26, 2001 and finished December 31, 2001. Resubmitted drawings from the architect were required. See the conditions list. A report was sent to the architect.
|
Plan resubmittals received | | | 12/28/2001 | | DONE |
|
|
|
Received two sets of resubmittal sheet A1.1 with cover letter. Routed to Carl Westfall.
|
Routing - PLANNING | 12/18/2001 | | 12/19/2001 | | |
|
|
|
Failed. Sarah Schafer. Does not comply with conditions of DRH01-205.
|
Routing - PLUMBING | 12/13/2001 | | 12/18/2001 | | PASS |
|
|
|
verify thermol expantion tank sizing with field inspector, if an automatic soap dispensor is installed at the janitor sink, provide a water supply for it, if 1st floor isnt concrete, provide a drip pan for the water heater, table 7-5 note, run 2 1/2" vent to the water closet at col. D-8, 2" vents at col. A-3 page M3.0 must tie together above flood level rim of the fixtures,
|
Routing - PUBLIC WORKS | 12/11/2001 | | 12/13/2001 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 12/7/2001 | | DONE |
|
|
|
1. Plans not fully dimensioned.
|
Application received | | | 12/7/2001 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 12/7/2001 | | DONE |
|
|
|
|