Permit Information
Permit NumberBLD01-03237
StatusFinaled
Name HEWLETT-PACKARD
Site Address 11311 W CHINDEN BLVD
Project NameHP #2-2 LOWER
Customer Number 
ePlanReviewNo
Description
(HP #2 BLDG-2 LOWER)(DP LAB ROOMS) - To perform selective demolition of interior non-bearing walls, mechanical, electrical, plumbing and to cut two new openings in concrete floor for new mechanical per engineering. To remodel previous test area and install a premanufactured 'environmental room' test unit and a 'prototype room' test and monitoring room. Work includes upgrade of electrical, mechanical, plumbing, sprinkler and alarm systems to meet special needs for testing; construction of new interior, non-combustible, non-bearing walls with insulation & sheetrock covering, all per approved plans, red-line notes on plans and the attached plan reviewer comments by all reviewing agencies. NOTE: This building is fully sprinklered for allowable area increase. A Letter of Completion / Compliance is required for this scope of work when final inspections are approved. PC#01-937/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD4/14/20064/14/20064/17/2006 DONE
First Notice has not been responded to.
First Notice3/27/20063/27/20064/14/2006 DONE
DetailsJim Sly
BLD-Final3/27/20063/27/20063/27/2006PPASS
DetailsJim Sly
Final R. Owen C/C Cathy W.
DOC - Permit Finaled3/27/20063/23/20063/27/2006APASS
DetailsJim Sly
Previously finaled by Russ Owen....C/C by Cathy W.
Letter of compliance  9/30/2002 DONE
Letter of Compliance #22738 issued 9-30-02.
BLD-Final5/22/20025/23/20025/23/2002APASS
DetailsRuss Owen
Scheduled by a contractor via Hello! on 05/22/2002 at 13:33:10. Contact: ###-####.
FIRE-Final Inspection3/28/20023/28/20023/28/2002APASS
DetailsRick Jackson
Scheduled by Inspector: 409 On 3/28/2002 8:19:57 AM
Issue & PRINT to be Invoiced  2/4/2002 DONE
Plan resubmittals received  2/1/2002 DONE
Received two sets of resubmittal sheets S2.1 and S2.2. routed to Dan Stuart.
Additional plans submitted  2/1/2002 PASS
NEW REVISED STRUCTURAL SHEETS PROVIDED. WILL INSERT INTO PLANS ALLREADY AT PERMIT DESK FOR ISSUE & INTO OFFICE PLAN COPY.
PLANS/APPL TAKEN TO FRONT DESK  1/31/2002 PASS
TO PERMIT DESK FOR ISSUE PROCESSING.
Inspection Record Card- Bld  1/31/2002 DONE
Print Occupancy Form  1/31/2002 DONE
Telephone call  1/31/2002 DONE
LEFT MESS FOR JOHN MULLIN THAT PERMIT IS READY
Plan assigned to (DRS)12/24/2001 1/31/2002 PASS
DetailsDan Stuart
1/31/2002 07:29:15 DRS - activity updated through activity BLDA022 from case BLD01-03237.
Routing - FIRE1/25/20021/28/20021/28/2002 PASS
DetailsBill Alexander
Plan Review Completed(1st rev)  1/28/2002 DONE
Routing - PLAN CHECK1/11/2002 1/25/2002 PEND
Approved as noted and attached. Routing to fire code analyst for review.
Routing - PLUMBING12/26/2001 1/11/2002 PASS
these plans took so long to review because the arch. told me he would have the engineer call to answer questions and it took a week and a half, after my discussion with the engineer- move the icw r.p. to the main floor level over a 4" floor sink by the chillers, install a 1/2" r.p. in the basement over one of the sumps for the humidifiers. the sump pumps will have a gate or ball valve and check valve at the pumps. the chiller drain will not be directly connected to the sanitary sewer. floor sinks are to be trapped and vented.
Plan resubmittals received  1/2/2002 DONE
Received two sets of resubmittal sheet S2.2 to include structural calculations. routed to Dan Stuart.
Routing - PUBLIC WORKS12/24/2001 12/26/2001 PASS
First Notice12/20/200112/20/200112/20/2001 DONE
Plans ACCEPTED BY PLAN TECH  12/20/2001 DONE
Application received  12/20/2001  
Recd Pcfee & Taken To Pln CK  12/20/2001 DONE
Routing - PLAN CHECK1/28/2002 1/31/2001 PASS
APPROVED AS NOTED AND ATTACHED PLAN REVIEW COMMENTS ALL PART OF THE APPROVED PLANS.