Permit Information
Permit NumberBLD02-00097
StatusFinaled
Name ALBERTSONS EXPRESS
Site Address 1525 S ORCHARD ST
Project NameALBERTSONS #162
Customer Number 
ePlanReviewNo
Description
Albertsons Express # 162 fuel center ( C-store) * To construct a new 2,029 sq. ft. metal framed, "A" express convenience store, with related on site work and lanscaping, with owner supplied merchandising fixtures and demolition of an existing 1,612 sq. ft. building. All construction per the approved plans and attached comment list. MJP DRH01-00194 PC#031-02
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  7/3/2008 DONE
BLD-Final10/18/200210/18/200210/18/2002 DONE
DetailsTom Arcoraci
Final - approved by Tom for perm. occ.
Permanent occupancy UNPAID FEE  10/18/2002 DONE
Perm. Occ. Cert. #9406 issued 10-18-02 to Albertson's Express.
Permanent Occupancy 10/16/200210/16/2002 DONE
Details
Temporary occupancy  9/30/2002 DONE
Temp. Occ. Cert. #4868 issued 9-30-02 to Albertson's Express #162.
BLD-Final9/26/20029/27/20029/27/2002PPART
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 09/26/2002 at 22:40:06. Contact: ###-####. ok for temp pending plumbing 9/27/2002 3:05:20 PM
BLD-Final9/25/20029/26/20029/26/2002PNR
DetailsTom Arcoraci
REX; Phone #: ###-#### Internet Inspection Request from: Darla Downs needs plumb ok 9/26/2002 4:00:59 PM
FIRE-Final Inspection9/24/20029/25/20029/25/2002APASS
DetailsTroy Cobbley
fire life safety finaled 9/25/2002 8:48:35 AM
PubWorks Occupancy Approval9/23/20029/23/20029/25/2002 DONE
Drainage project complete, signed permanent occupancy 9/26/02. G.Fitts
Code Occupancy Approval  9/25/2002 PASS
ALL IN FINAL SIGNED OFF.
FIRE-Final Inspection9/22/20029/23/20029/23/2002AFAIL
DetailsTroy Cobbley
fire extinguishers on the gas islands need to have the correct inspection tags. all other items on the correction notice have been corrected 9/23/2002 3:50:10 PM
FIRE-Final Inspection9/6/20029/9/20029/9/2002AFAIL
DetailsTroy Cobbley
provide tags on island fire extinguishers, test duct smoke detector, test automatic shutoff of pumps, provide "door to remain unlocked" sticker, remove lock on cooler door, provide address on orchard street side of building, provide red curbing as discussed 9/9/2002 9:17:08 AM
BLD-Framing/Rough-in8/29/20028/30/20028/30/2002APART
DetailsTom Arcoraci
SUSPENDED CEILING ###-#### REX grid ok 8/30/2002 9:06:33 AM
BLD-Framing/Rough-in8/9/20028/12/20028/12/2002PPASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 08/09/2002 at 17:15:53. Contact: ###-####.
BLD-Framing/Rough-in8/5/20028/6/20028/6/2002APART
DetailsTom Arcoraci
###-#### rex needs all rough ins ok to cover ext walls 8/6/2002 9:29:56 AM
BLD-Other6/6/20026/10/20026/10/2002APASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 06/06/2002 at 11:26:13. Contact: ###-####. set on lot by eng 6/10/2002 10:11:14 AM
(F) Reprint permit  5/22/2002  
Issue PAID IN FULL permit  5/21/2002 DONE
Routing - PLAN CHECK3/28/2002 3/29/2002 PASS
PLANS/APPL TAKEN TO FRONT DESK  3/29/2002 DONE
Print Pending Permit.LaserJet4  3/29/2002 DONE
Case Summary (BLD)  3/29/2002 DONE
Inspection Record Card- Bld  3/29/2002 DONE
Print Occupancy Form  3/29/2002 DONE
Telephone call  3/29/2002 DONE
talked to adam to verify plans are ready
Plan assigned to (M_P)1/17/2002 3/29/2002 PASS
DetailsMike Phillips
3/29/2002 09:31:25 M_P - activity updated through activity BLDA022 from case BLD02-00097.
Routing - PLAN CHECK3/27/2002 3/28/2002  
Routing - PUBLIC WORKS3/27/2002 3/28/2002  
Routing - PLANNING Land Div3/26/2002 3/26/2002 PASS
Land division ok. Returned to Plan Review. (blc)
Routing Off Site - STRUCTURAL3/13/2002 3/15/2002 PASS
contacted pdq to take revies calcs and geotec report of 3-8-02 to outside eng. kmm
Routing - PLAN CHECK2/19/2002 3/13/2002 PEND
Waiting for outside engineering, Public Works and Land Division to approve prior to issuing permit.
Routing - PLANNING Land Div2/19/2002 2/19/2002 FAIL
Still need deeds from 1972 to present. Returned to Plan Review. (blc)
Routing - FIRE2/12/2002 2/15/2002 PASS
Routing - PLAN CHECK2/5/2002 2/12/2002 FAIL
Plan review completed, additional information required for further review, prior to issuing permit.
Print Pending Permit.LaserJet4  2/12/2002  
Routing - PLUMBING1/30/2002 2/5/2002 PASS
locate r.p. for the soda mechine over the mop sink to handle spillage, provide a floor sink below r.p's noted on page 4.1 note 4108, pipe 1 1/4" to most remote toilet, verify thermol expantion tank sizing with manufacturer for required 50 gal. water heater/ 30 gal water heater ok with recirc to farthest lav per cdhd approval, pipe water heater t&p drain to janitor sink.
Routing - PLANNING1/24/2002 1/29/2002 PASS
Approve per DRH01-194.
Routing - PUBLIC WORKS1/17/2002 1/24/2002 FAIL
Requires street light plan
Routing Off Site - STRUCTURAL1/17/2002 1/24/2002 FAIL
Contacted PDQ to take plans to outside eng. kmm
Second review required by outside engineering firm.
Plan routing begun/NEW & ADDTN  1/17/2002 DONE
Routing - PLANNING Land Div1/17/2002 1/17/2002 FAIL
This is a portion of Lot 1, Block 17, Lambachs Hillboro Subdivision, so need to see chain of deeds to 10/30/65 to verify legal land division. Faxed Adam Mow. Routed to Public Works. (blc)
Plans ACCEPTED BY PLAN TECH  1/17/2002 DONE
First Notice1/16/20021/16/20021/16/2002 DONE
Application received  1/16/2002  
Recd Pcfee & Taken To Pln CK  1/16/2002