Fee Review-notes | 1/25/2002 | 1/25/2002 | 6/24/2002 | | DONE |
|
|
|
|
Permanent occupancy UNPAID FEE | | | 4/12/2002 | | DONE |
|
|
|
Perm. Occ. Cert. #9103 issued 4-12-02 to Hastings (expansion).
|
Permanent Occupancy | | 4/9/2002 | 4/9/2002 | | DONE |
|
|
|
|
BLD-Final | 4/8/2002 | 4/9/2002 | 4/9/2002 | A | PASS |
Tom Arcoraci
|
|
|
###-#### jim ok for perm occ 4/9/2002 11:23:38 AM
|
FIRE-Alarm Testing | 4/5/2002 | 4/8/2002 | 4/8/2002 | A | PASS |
Troy Cobbley
|
|
|
fire alarm system finaled 4/8/2002 10:11:16 AM
|
FIRE-Final Inspection | 4/5/2002 | 4/8/2002 | 4/8/2002 | A | PASS |
Troy Cobbley
|
|
|
fire alarm, fire sprinklers and fire/life safety finaled 4/8/2002 10:11:47 AM
|
BLD-Final | 4/5/2002 | 4/8/2002 | 4/8/2002 | A | FAIL |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 04/05/2002 at 17:02:49. Contact: ###-####. entry door not set up to brake away at 30 lbs need to remove thumb latches with key and post sign above door dr to remain unlocked during bs hours 4/8/2002 12:09:27 PM
|
Temporary occupancy | | | 4/8/2002 | | DONE |
|
|
|
Temp. Occ. Cert. #4783 issued 4-8-02 to Hastings (expansion).
|
FIRE-Final Inspection | 4/5/2002 | 4/5/2002 | 4/5/2002 | P | PASS |
Troy Cobbley
|
|
|
life/safety finaled. 4/5/2002 3:13:48 PM
|
FIRE-Alarm Testing | 4/5/2002 | 4/5/2002 | 4/5/2002 | P | FAIL |
Troy Cobbley
|
|
|
two duct detectors in the new area of the store do not work and need testing, signals need to be reverified to the monitoring station (alarm,trouble and supervisiory) 4/5/2002 3:12:09 PM
|
BLD-Final | 4/5/2002 | 4/5/2002 | 4/5/2002 | P | NR |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 04/05/2002 at 09:40:18. Contact: ###-####.
|
FIRE-Final Inspection | 4/3/2002 | 4/3/2002 | 4/3/2002 | P | NR |
Troy Cobbley
|
|
|
fire alarm and life/safety not ready 4/3/2002 4:20:06 PM
|
FIRE-Final Inspection | 4/2/2002 | 4/2/2002 | 4/2/2002 | P | PASS |
Troy Cobbley
|
|
|
Fire sprinklers OK
|
BLD-Framing/Rough-in | 3/28/2002 | 3/29/2002 | 3/29/2002 | A | PART |
Dave Hannah
|
|
|
grid ceiling cover- jim ###-#### ok to cover 3/29/2002 12:15:38 PM
|
BLD-Framing/Rough-in | 3/27/2002 | 3/28/2002 | 3/28/2002 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 03/27/2002 at 17:59:34. Contact: ###-####. Coffee room..... Need (1) lateral wall brace check at ceiling insp. 3/28/2002 10:26:18 AM
|
BLD-Wall cover | 3/27/2002 | 3/28/2002 | 3/28/2002 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 03/27/2002 at 18:00:19. Contact: ###-####. OK to cover wall at coffee room. 3/28/2002 10:26:45 AM
|
BLD-Framing/Rough-in | 3/28/2002 | 3/28/2002 | 3/28/2002 | P | PART |
Dave Hannah
|
|
|
CEILING GRID INSPECT ###-#### JIM pods ok but still need to wire ends of runs 3/28/2002 3:18:38 PM
|
BLD-Wall cover | 3/19/2002 | 3/19/2002 | 3/19/2002 | P | PASS |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 03/19/2002 at 10:55:10. Contact: ###-####.
|
BLD-Framing/Rough-in | 3/15/2002 | 3/15/2002 | 3/15/2002 | P | PART |
Dave Hannah
|
|
|
fr for walls--insp- jim ###-#### front office areaok need top of wall to roof 45 angel braces 3/15/2002 5:37:08 PM
|
Plan assigned to (CJW) | 1/29/2002 | | 3/8/2002 | | PASS |
Carl Westfall
|
|
|
3/8/2002 09:25:22 CJW - activity updated through activity BLDA022 from case BLD02-00161.
|
Routing - PLAN CHECK | 3/5/2002 | | 3/8/2002 | | PASS |
|
|
|
(3-6-02) Completed resubmittal review. Required response to 3 items. Faxed report to the architect. (3-8-02) Completed 2nd resubmittal review. Drawings approved with conditions.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/8/2002 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 3/8/2002 | | DONE |
|
|
|
|
Print Occupancy Form | | | 3/8/2002 | | DONE |
|
|
|
|
Telephone call | | | 3/8/2002 | | DONE |
|
|
|
SPOKE WITH KYLE PLANS READY
|
Issue PAID IN FULL permit | | | 3/8/2002 | | DONE |
|
|
|
|
Plan resubmittals received | | | 3/7/2002 | | DONE |
|
|
|
Received two sets of resubmittal sheets F-1, A-3, A-1 with cover letter. Routed to Carl Westfall.
|
Routing Off Site - C.D.H | 2/28/2002 | | 3/5/2002 | | PASS |
|
|
|
Carol took plans to CDH and gave to Bud. kmm
|
Plan resubmittals received | | | 3/1/2002 | | DONE |
|
|
|
Received two copies of revised sheets A-1, A-3,F-1, P-1, one plan response. Routed to Carl W. kmm
|
Routing - PLUMBING | 2/25/2002 | | 2/28/2002 | | PASS |
|
|
|
after conversation with ECI, provide a floor sink and water for equipment at the island in the coffee area, all floor sinks must be exposed, out from under cabinets and equipment, additional cross connection protection may be required, if an automatic soap dispensor is installed at the mop sink, provide a water supply for it.
|
Plan Review Completed(1st rev) | | | 2/25/2002 | | |
|
|
|
Failed first UBC review.
|
Routing - FIRE | 2/20/2002 | | 2/25/2002 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 1/29/2002 | | 2/20/2002 | | |
|
|
|
Failed first UBC review. UBC plan review started February 15 and finished February 20, 2002. Resubmitted drawings were required from the architect. See the conditions list. A copy of the plan review report was sent to the architect.
|
Routing - PUBLIC WORKS | 1/29/2002 | | 1/29/2002 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 1/28/2002 | | DONE |
|
|
|
|
Application received | | | 1/25/2002 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 1/25/2002 | | DONE |
|
|
|
|