BLD-Final | 7/1/2002 | 7/2/2002 | 7/2/2002 | A | FAIL |
Tom Arcoraci
|
|
|
JUSTIN ###-#### cn posted 7/2/2002 9:20:46 AM
|
BLD-Final | 7/2/2002 | 7/2/2002 | 7/2/2002 | P | PASS |
Tony Young
|
|
|
fn justin- ###-#### for duplex
|
DOC - Permit Finaled | 7/2/2002 | 7/2/2002 | 7/2/2002 | P | PASS |
Tony Young
|
|
|
Finaled by inspector at 7/2/2002 3:53:03 PM
|
BLD-Framing/Rough-in | 5/23/2002 | 5/24/2002 | 5/24/2002 | A | PASS |
Tony Young
|
|
|
###-####
int shear ok 5/24/2002 9:15:32 AM
|
BLD-Framing/Rough-in | 5/21/2002 | 5/22/2002 | 5/22/2002 | A | NR |
Tony Young
|
|
|
DRY WALL 1 UNIT ONLY JUSTIN ###-####
|
BLD-Framing/Rough-in | 5/15/2002 | 5/16/2002 | 5/16/2002 | A | PASS |
Tony Young
|
|
|
###-#### justin
insulation ok also 5/16/2002 9:23:46 AM
|
BLD-Energy code compliance | 5/13/2002 | 5/14/2002 | 5/14/2002 | A | NR |
Tony Young
|
|
|
conf. only 5/14/2002 11:10:13 AM
|
BLD-Conference | 5/14/2002 | 5/14/2002 | 5/14/2002 | A | PASS |
Carl Dependahl
|
|
|
consulted bldr & 415 onsite re stairs & 1hr walls....maintain min 6" run at narrow side; otherwise ok per approved plan.
' 5/14/2002 11:22:50 AM 5/14/2002 11:28:13 AM
|
BLD-Energy code compliance | 5/10/2002 | 5/13/2002 | 5/13/2002 | P | NR |
Tony Young
|
|
|
insu ###-#### justin
|
BLD-Conference | 5/10/2002 | 5/13/2002 | 5/13/2002 | A | PART |
Tony Young
|
|
|
c/n still posted, met w/ G.S. on misc. items 5/13/2002 11:41:06 AM
|
BLD-Conference | 5/10/2002 | 5/10/2002 | 5/10/2002 | P | FAIL |
Tony Young
|
|
|
conf- mark ###-#### & justin ###-####
c/n still posted 5/10/2002 3:58:14 PM
|
BLD-Framing/Rough-in | 5/8/2002 | 5/9/2002 | 5/9/2002 | A | FAIL |
Jim Storey
|
|
|
1. TOWN HOUSE PARAPETS - A parapet is not required on exterior walls less than 3 feet from a property line for R-3 and U Occupancies built as townhouses with not more than 3,000 square feet for all floor levels (including garage) when the following is provided: (1) Openings in the roof shall not be located within 5 feet of the 1-hour fire-resistive exterior wall, and (2) The entire building shall be provided with not less than a Class B roofing assembly. (Boise City Code 4-02-15)
2. (Wall membrane penetrations) Membrane penetrations of fire-resistive walls shall comply with 1997 UBC Section 709.6 as required for wall through penetrations. (1997 UBC 709.7)
3. (Winding stairways) In R-3 Occupancies and in private stairways in R-1 Occupancies, winding stairways may be used if the required width of run is provided at a point not more than 12 inches from the side of the stairway where the treads are narrower, but in no case shall the width of run be less than 6 inches at any point. (1997 UBC 1003.3.3.8.2)
4. mech and plm cut out bci joist need repair doc./ part insp fire blk and sheer nailling not per engineering.
|
BLD-Framing/Rough-in | 5/3/2002 | 5/6/2002 | 5/6/2002 | P | NR |
Tony Young
|
|
|
###-#### justin
|
BLD-Conference | 4/12/2002 | 4/12/2002 | 4/12/2002 | A | PASS |
Tony Young
|
|
|
Added by Inspector: 415 On 4/12/2002 9:34:41 AM conf on firewall under patio,,, do as plan says, (not needed) by front entry
|
BLD-Framing/Rough-in | 4/8/2002 | 4/9/2002 | 4/9/2002 | P | PART |
Tom Arcoraci
|
|
|
reinspect shear 4/8/2002 3:45:55 PM rear floor straps ok to cover 4/9/2002 1:09:43 PM
|
BLD-Framing/Rough-in | 4/8/2002 | 4/8/2002 | 4/8/2002 | P | PART |
Tony Young
|
|
|
separation wall--clyde ###-####
attic seperation walls ok 4/8/2002 3:50:42 PM
|
BLD-Framing/Rough-in | 4/1/2002 | 4/2/2002 | 4/2/2002 | P | PART |
Carl Dependahl
|
|
|
clyde -###-#### 2nd fl inner layers of dbl 1hr walls ok to plate line...recall for attic separation insp 4/2/2002 4:55:06 PM
|
BLD-Conference | 4/2/2002 | 4/2/2002 | 4/2/2002 | A | PASS |
Carl Dependahl
|
|
|
Added by Inspector: 340 On 4/2/2002 11:16:05 AM w/ framer at site...add 1hr const at floor lines & property line walls at "offset" at front of bldg...no ladder partition backing at 1hr walls (unless gyp runs thru); needs 1hr wall inspection for 2nd fl...chk. for dbl 1hr at attic.
|
BLD-Framing/Rough-in | 3/27/2002 | 3/27/2002 | 3/27/2002 | P | PART |
Tony Young
|
|
|
CLYDE ###-#### SHEER WALL
lower fire wall ok, ///conf. ok on 12' 2x4 walls on 12" o.c. as long as eng. oks 3/27/2002 3:16:58 PM
|
BLD-Foundation | 3/15/2002 | 3/18/2002 | 3/18/2002 | A | PART |
Tony Young
|
|
|
Scheduled by Inspector: 415 On 3/15/2002 3:25:22 PM HAS INT FTGS W/ SIMPSON HTT16'S AT ENTRY AREA...CHK W/ OTHER HD'S AT FRAME INSP. 3/18/2002 9:36:28 AM
|
BLD-Foundation | 3/15/2002 | 3/15/2002 | 3/15/2002 | P | NR |
Tony Young
|
|
|
###-#### ED
steel not in yet, forms not in place 3/15/2002 3:06:24 PM
|
BLD-Footing | 3/14/2002 | 3/14/2002 | 3/14/2002 | P | PART |
Tony Young
|
|
|
justin ###-####
|
Issue PAID IN FULL permit | | | 3/14/2002 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 3/4/2002 | | |
|
|
|
|
Plan Review Report | | | 3/4/2002 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/4/2002 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 3/4/2002 | | |
|
|
|
|
Telephone call | | | 3/4/2002 | | DONE |
|
|
|
###-####
|
Routing - PLAN CHECK | 2/19/2002 | | 3/4/2002 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 2/24/2002 | | 3/4/2002 | | PASS |
Steve Munroe
|
|
|
3/4/2002 13:08:08 SAM - activity updated through activity BLDA022 from case BLD02-00231.
|
Plan Reviewer's activity | | | 2/25/2002 | | PEND |
|
|
|
2/25/02 Only one set of plans is being approved due to excessive red-lining, plus only one set that was submitted was complete.
|
Plan Reviewer's activity | | | 2/25/2002 | | PEND |
|
|
|
2/25/02 8:45 I talked to Bob, with Pinnacle engineering. I asked about sheet 13, holdown calls for a STHD14 but detail on sheet 31 calls for HTT16. I also asked him about details on sheets 28, 29 and 30. He is going to call Justin Jayo and then get back with me.
|
Pending Assignment by DJO | 2/5/2002 | | 2/24/2002 | | DONE |
Dan Overy
|
|
|
2/24/2002 09:41:21 SAM - activity updated through activity BLDA183 from case BLD02-00231.
|
Routing - PUBLIC WORKS | 2/5/2002 | | 2/19/2002 | | PASS |
|
|
|
|
Routing - PLANNING | 2/14/2002 | 2/14/2002 | 2/14/2002 | | PASS |
|
|
|
Revised site plan.
|
Routing - PLANNING | 2/5/2002 | | 2/8/2002 | | FAIL |
|
|
|
Driveway not 50 ft. from intersection. Talked to Doug Jayo.
|
Application received | | | 2/5/2002 | | |
|
|
|
|