Permit Information
Permit NumberBLD02-00340
StatusFinaled
Name VICTORIA'S SECRET
Site Address 350 N MILWAUKEE ST Unit: 1072
Project NameBTS - #1069/1070/1072
Customer Number 
ePlanReviewNo
Description
(VICTORIA'S SECRET)(BOISE TOWNE SQUARE-SPACE 1072) To remodel an existing retail space by incorporating the adjacent 2,933 sq.ft. area (Space 1069) to bring the total to 8,952 sq.ft. per approved plans. Work to include, construction of new storefront system and installation of new roll-up security grill, construction of a new exit corridor that will connect to the existing one-hour exit - passageway, construction of two new accessible restrooms, installation of new ceiling system, construction of new nonbearing partitions, to create new stock room, fitting rooms and retail space, Miscelaneous related finishes, NOTE: This building is fully fire sprinklered with a Smoke evacuation system, any alterations or modifications to the fire sprinkler system shall be per NFPA #13 as regulated by the fire department, The smoke evacuation system shall remain fully operational as installed under the 1985 UBC. (pc#102-02) rmh
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes7/17/20037/17/20037/17/2003 DONE
Permanent occupancy  6/14/2002 DONE
Perm. Occ. Cert. #9169 issued 6-14-02 to Victoria's Secret at Boise Towne Square. (expansion on lower level)
Permanent Occupancy 6/12/20026/12/2002 DONE
Details
FIRE-Final Inspection6/11/20026/12/20026/12/2002ACANC
DetailsTroy Cobbley
MIKE ###-####
FIRE-Final Inspection6/11/20026/12/20026/12/2002APASS
DetailsTroy Cobbley
fire sprinkler, fire alarm and fire life/safety finaled 6/12/2002 11:37:48 AM
BLD-Final6/11/20026/12/20026/12/2002PPASS
DetailsRuss Owen
###-#### mikeok perm oc. 6/12/2002 4:15:10 PM
FIRE-Final Inspection6/10/20026/11/20026/11/2002AFAIL
DetailsTroy Cobbley
Life safety and fire alarm OK, but fire sprinklers still need two sprinkler heads changed out and stock in back room needs to be removed from the top shelf 6/11/2002 3:22:30 PM
BLD-Final6/10/20026/11/20026/11/2002PCANC
DetailsRuss Owen
MIKE ###-####
BLD-Framing/Rough-in5/31/20026/3/20026/3/2002AFAIL
DetailsRuss Owen
CEILING INSP- MIKE- ###-#### . light cans need wires called this number waiting for return call contractor not on site. 6/3/2002 4:57:36 PM
BLD-Framing/Rough-in5/7/20025/7/20025/7/2002PPART
DetailsDave Hannah
###-#### MIKE front entry way ok to cover 5/7/2002 1:57:47 PM
BLD-Framing/Rough-in4/17/20024/18/20024/18/2002APART
DetailsRuss Owen
###-#### mike Ok to cover front roof structure, also grid ok to drop all tile. 4/18/2002 12:36:18 PM
Issue PAID IN FULL permit  4/2/2002 DONE
Routing - PLAN CHECK3/26/2002 4/1/2002 PASS
Case Summary (BLD)  4/1/2002 DONE
PLANS/APPL TAKEN TO FRONT DESK  4/1/2002 PASS
Inspection Record Card- Bld  4/1/2002  
Print Occupancy Form  4/1/2002  
Telephone call  4/1/2002 DONE
left mess that permit is ready
Plan assigned to (R_H)2/25/2002 4/1/2002 PASS
Details
4/1/2002 10:28:30 RMH - activity updated through activity BLDA022 from case BLD02-00340.
Plan resubmittals received  3/28/2002 DONE
Received three sets of resubmittal sheets A00.0, A00.4, A02.1, A08.5, A08.6, A12.1 with cover letter. Routed to Ron Hill.
Routing - FIRE3/20/2002 3/26/2002 PASS
Plan Reviewer's activity  3/20/2002 FAIL
DetailsRon Hill
Faxed corrections to Tim Schenk and Cortland Morgan, On 3/20/02 Routed plans to the fire department on same date.
Routing - PLAN CHECK2/25/2002 3/20/2002 FAIL
DetailsRon Hill
Faxed and mailed requirements on 2/20/02, routed to fire same day.
Routing - PUBLIC WORKS2/25/2002 2/25/2002 PASS
First Notice2/21/20022/21/20022/21/2002 DONE
Details
Recd Pcfee & Taken To Pln CK  2/21/2002 DONE
Plans ACCEPTED BY PLAN TECH  2/21/2002 DONE
Application received  2/21/2002