Permit Information
Permit NumberBLD02-00570
StatusFinaled
Name PC300 LLC
Site Address 300 W MAIN ST Unit: 101
Project Name300 MAIN
Customer Number 
ePlanReviewNo
Description
(DR JULIE CONYERS)(300 MAIN - Suite #101) Remodel for a new 1,291 sq.ft. tenant space for a doctor's office on first floor in existing building per approved plans on file. Work under this permit will also include extending the one-hour rated exit corridor from the west end to the center rated entry/lobby and constructing a new Men's core restroom. Work to include new portions of one-hour rated corridor construction, 20 minute rated doors where required, new interior walls and doors, accessible restrooms, new suspended ceiling installation, interior finish, new counters/sinks, mechanical work, plumbing work, and electrical work. Building rated corridor, rated entry/lobby, and exterior exiting (stairs, handrails/guardrails) must be completed prior to issuing a Certificate of Occupancy for the tenant. A CERTIFICATE OF OCCUPANCY IS TO BE ISSUED WHEN COMPLETED AND APPROVED. This space will occupy Suite #101 and former Suite #103 which were done under "vanilla finish" permits BLD02-00384 and BLD01-02608. NOTE: This building is NOT fire sprinklered. (PC#0158-02) JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes7/17/20037/17/20037/17/2003 DONE
Permanent occupancy  12/24/2002 DONE
Perm. Occ. Cert. #9483 issued 12-18-02 to Dr. Julie Conyers.
Permanent Occupancy 12/17/200212/17/2002 DONE
Details
BLD-Final12/17/200212/17/200212/17/2002 DONE
DetailsCarl Dependahl
Final - approved/perm.occ.
BLD-Final5/9/20025/10/20025/10/2002APART
DetailsCarl Dependahl
dave ###-#### c/n firestops/seal at door, ok for t/o 5/10/2002 12:43:15 PM
Temporary occupancy  5/10/2002 DONE
Temp. Occ. Cert.#4803 issued 5-10-02 to Dr. Julie Conyers.
FIRE-Final Inspection5/9/20025/9/20025/9/2002APASS
DetailsRick Jackson
Added by Inspector: 409 On 5/9/2002 8:17:00 AM occ approved; shell not complete under BLD01-02970 and is under temp per Dave Miller
FIRE-Final Inspection5/6/20025/6/20025/6/2002PFAIL
DetailsRick Jackson
fire fn insp- harold ###-#### rated doors not installed; see BLD01-02970 for shell requirements; told GC to go through Dave Miller for temp occ requirements 5/6/2002 3:44:48 PM
BLD-Final5/6/20025/6/20025/6/2002PFAIL
DetailsCarl Dependahl
FOR OCCUPANCY ###-#### DAVE
BLD-Framing/Rough-in5/1/20025/2/20025/2/2002APART
DetailsCarl Dependahl
dave ###-#### fr insp grid ok pend ele, hvac. 5/2/2002 12:22:17 PM
BLD-Framing/Rough-in4/26/20024/29/20024/29/2002APART
DetailsCarl Dependahl
###-#### DAVE walls ok 4/29/2002 1:53:28 PM
BLD-Conference4/25/20024/26/20024/26/2002APASS
DetailsCarl Dependahl
c/n issued, need details as req'd; install appropriate fire assy's at lids, show listg for glass block...etc. see previous c/ns 4/26/2002 2:01:19 PM
BLD-Framing/Rough-in4/25/20024/25/20024/25/2002PFAIL
DetailsCarl Dependahl
dave ###-#### please call before going out...c/n, firestops, grid, etc. walls ok'dby 408? 4/26/2002 4:17:07 PM
BLD-Framing/Rough-in4/15/20024/15/20024/15/2002PPASS
DetailsTom Arcoraci
###-#### dave needs fire stop at pents in wall can see at grid inspection 4/15/2002 2:15:16 PM
Plan assigned to (JCB)3/21/2002 4/11/2002 PASS
DetailsJason Blais
4/11/2002 13:28:52 JCB - activity updated through activity BLDA022 from case BLD02-00570.
Routing - PLAN CHECK4/10/2002 4/11/2002 PASS
Permit and plans approved and taken to front desk.
Plan resubmittals received  4/11/2002 DONE
Received two sets of resubmittal sheets A1.1, A1.2, A1.3, with cover letter. Routed to Jason Blais.
PLANS/APPL TAKEN TO FRONT DESK  4/11/2002 PASS
Inspection Record Card- Bld  4/11/2002 DONE
Print Occupancy Form  4/11/2002 DONE
Telephone call  4/11/2002 DONE
LEFT MESSAGE PERMIT READY AND FEES
Issue PAID IN FULL permit  4/11/2002 DONE
Routing - PLAN CHECK4/3/2002 4/10/2002 FAIL
In reviewing resubmittal drawings two items still need to be properly addressed. Called architect and went over items. It was acknowledged and resubmittal sheets will be coming.
Telephone call  4/10/2002 DONE
Called architect and let them know two items still need to be addressed. Resubmittal sheets required. Acknowledged.
Routing - FIRE3/28/20024/2/20024/3/2002 PASS
DetailsBill Alexander
Plan Review Completed(1st rev)  4/3/2002 DONE
Plan resubmittals received  4/2/2002 DONE
Received two sets of resubmittal sheets A1.1, A1.2, A1.3 with cover letter. Routed to Jason Blais.
Routing - PLUMBING3/27/2002 3/28/2002 PASS
per plans and 2000 upc.
Plan resubmittals requested  3/27/2002  
Plan resubmittals and response required for further review.
Routing - PLAN CHECK3/26/2002 3/27/2002 FAIL
Plan review report sent and faxed to architect. Plan resubmittals and response required for further review. Plans routed to Plumbing and Fire Dept. for review.
Routing - PUBLIC WORKS3/21/2002 3/26/2002 PASS
Plans ACCEPTED BY PLAN TECH  3/18/2002 DONE
1. Verbage on plans state, "MECHANICAL, HVAC, AND PLUMBING TO BE 'DESIGN BUILD' BY MECHANICAL CONTRACTOR" and "ELECTRICAL, LIGHTING AND COMMUNICATIONS TO BE 'DESIGN/BUILD' BY ELECTRICAL CONTRACTOR.
First Notice3/15/20023/15/20023/15/2002 DONE
Application received  3/15/2002  
Recd Pcfee & Taken To Pln CK  3/15/2002 DONE