BLD-Final | 8/12/2002 | 8/13/2002 | 8/13/2002 | A | FAIL |
Steven Webb
|
|
|
jay ; Phone #: ###-#### C/N--Need to seal garage penetration; verify rim insulation; full coverage on visqueen in crawl; an additional ballister on deck guardrail and handrail needed on deck stairs. 8/13/2002 10:51:33 AM
|
BLD-Final | 8/13/2002 | 8/13/2002 | 8/13/2002 | P | PASS |
Steven Webb
|
|
|
jay may need to use back door as jay is putting in hard wood at front door; Phone #: ###-#### C. of C. #23304 issued. 8/13/2002 2:02:26 PM
|
DOC - Permit Finaled | 8/13/2002 | 8/13/2002 | 8/13/2002 | P | PASS |
Steven Webb
|
|
|
Finaled by inspector at 8/13/2002 2:02:32 PM
|
BLD-Framing/Rough-in | 6/14/2002 | 6/17/2002 | 6/17/2002 | A | PASS |
Steven Webb
|
|
|
MIKE ###-#### Ok to cover 6/17/2002 11:44:46 AM
|
BLD-Framing/Rough-in | 6/13/2002 | 6/13/2002 | 6/13/2002 | P | PART |
Steven Webb
|
|
|
###-#### mike fr C/N--Ok to insulate 6/13/2002 4:02:12 PM
|
BLD-Framing/Rough-in | 6/3/2002 | 6/4/2002 | 6/4/2002 | P | PART |
Steven Webb
|
|
|
MIKE ###-#### SHEER WALL Ok to side. 6/4/2002 3:08:44 PM
|
BLD-Framing/Rough-in | 5/31/2002 | 6/3/2002 | 6/3/2002 | A | FAIL |
Steven Webb
|
|
|
###-#### C/N--Install holdowns, missing shear panels, nail per plans and excessive penetration on nails in panels. 6/3/2002 8:57:04 AM
|
BLD-Energy code compliance | 5/30/2002 | 5/31/2002 | 5/31/2002 | P | NR |
Steven Webb
|
|
|
SHEER WALL ###-#### JAY--Shear not energy--not ready for inspection. 5/31/2002 3:01:24 PM
|
BLD-Foundation | 4/30/2002 | 5/1/2002 | 5/1/2002 | P | PART |
Steven Webb
|
|
|
###-#### JAY 75% ready at time of inspection. 5/1/2002 4:10:03 PM
|
BLD-Footing | 4/29/2002 | 4/30/2002 | 4/30/2002 | P | PASS |
Dave Hannah
|
|
|
###-#### JAY
|
Inspection Record Card- Bld | | | 4/29/2002 | | DONE |
|
|
|
|
Telephone call | | | 4/29/2002 | | DONE |
|
|
|
called left v-message for jay plans ready 4-29-02 ///dld
|
Issue PAID IN FULL permit | | | 4/29/2002 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 4/26/2002 | 4/26/2002 | 4/26/2002 | | PASS |
Dan Overy
|
|
|
4/26/2002 15:20:00 DJO - activity updated through activity BLDA022 from case BLD02-00893.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/26/2002 | | DONE |
|
|
|
|
Print Pending Permit.LaserJet4 | | | 4/26/2002 | | DONE |
|
|
|
|
Plan Review Report | | | 4/26/2002 | | DONE |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 4/26/2002 | | |
|
|
|
|
Routing - PUBLIC WORKS | 4/18/2002 | | 4/18/2002 | | PASS |
|
|
|
|
Routing - PLANNING | 4/16/2002 | | 4/17/2002 | | PASS |
|
|
|
|
Application received | | | 4/16/2002 | | |
|
|
|
|
Pending Assignment by DJO | 4/16/2002 | | | | |
Dan Overy
|
|
|
|
Routing - PLAN CHECK | 4/18/2002 | | | | |
|
|
|
|