Fee Review-notes | 4/24/2002 | 4/24/2002 | 8/10/2004 | | DONE |
|
|
|
|
First Notice | | 9/18/2003 | 9/18/2003 | | DONE |
|
|
|
|
BLD-Aging Inspection | 8/15/2003 | 8/15/2003 | 8/15/2003 | | PASS |
Jim Storey
|
|
|
final ok 8/15/2003 8:17:19 AM
|
DOC - Permit Finaled | 8/15/2003 | 8/15/2003 | 8/15/2003 | A | PASS |
Jim Storey
|
|
|
Finaled by inspector at 8/15/2003 8:17:21 AM
|
Permanent occupancy | | | 6/18/2003 | | DONE |
|
|
|
Perm. Occ. Cert. #9694 issued 6-18-03 to American Ecology in the Lakepoint Centre Bldg. #1.
|
Permanent Occupancy | | 6/12/2003 | 6/12/2003 | | DONE |
|
|
|
|
BLD-Final | 6/11/2003 | 6/12/2003 | 6/12/2003 | A | PASS |
Jim Storey
|
|
|
pat; Phone #: ###-#### Internet Inspection Request from: Barbara Moore final ok 6/12/2003 3:30:47 PM
|
BLD-Final | 6/10/2003 | 6/11/2003 | 6/11/2003 | A | FAIL |
Jim Storey
|
|
|
pat; Phone #: ###-#### Internet Inspection Request from: Annette Moore smoke seal west door at receptionest. 6/11/2003 9:44:22 AM
|
BLD-Aging Inspection | 6/10/2003 | 6/10/2003 | 6/10/2003 | | FAIL |
Jim Storey
|
|
|
called jack to obtain final. 6/10/2003 2:57:27 PM
|
BLD-Aging Inspection | 4/10/2003 | 4/10/2003 | 4/10/2003 | | PART |
Jim Storey
|
|
|
east 1/2 sheer ok/ c/n to arch. 4/10/2003 2:23:31 PM
|
BLD-Final | 6/28/2002 | 7/1/2002 | 7/1/2002 | P | FAIL |
Jim Storey
|
|
|
###-#### ###-####previous c/n not done. 7/1/2002 1:05:56 PM
|
FIRE-Final Inspection | 6/28/2002 | 7/1/2002 | 7/1/2002 | A | PASS |
Rick Jackson
|
|
|
JACK ###-#### card not there; final okay 7/1/2002 8:45:15 AM
|
BLD-Final | 6/27/2002 | 6/28/2002 | 6/28/2002 | A | FAIL |
Jim Storey
|
|
|
1. (Main exit hardware) In B, F, M and S Occupancies, key-locking hardware may be used on the main exit where the main exit consists of a single door or pair of doors where there is a readily visible, durable sign on or adjacent to the door stating, "THIS DOOR MUST REMAIN UNLOCKED DURING BUSINESS HOURS". The sign shall be in letters not less than 1 inch high on a contrasting background. When unlocked, the single door or both leaves of a pair of doors must be free to swing without operation of any latching device. (1997 UBC 1003.3.1.8 Exception #1) When determining which door is the main exit door, consider the door that must be unlocked in order to conduct business. In other words, if the main exit door was locked, customers could not enter and business could not take place. Keeping the main exit door unlocked during business hours is therefore self regulating.
2. smoke seals and closers on all rated door openings.
3. gyp on coridor at recption rm. storage rm to tunnal gyp const.
|
FIRE-Final Inspection | 6/28/2002 | 6/28/2002 | 6/28/2002 | A | FAIL |
Rick Jackson
|
|
|
Added by Inspector: 409 On 6/28/2002 9:53:17 AM extinguishers; pull station obstructed by door
|
FIRE-Sprinkler Rough-in | 6/21/2002 | 6/21/2002 | 6/21/2002 | P | PASS |
Rick Jackson
|
|
|
Added by Inspector: 409 On 6/21/2002 3:43:34 PM okay to cover
|
BLD-Framing/Rough-in | 5/30/2002 | 5/31/2002 | 5/31/2002 | A | PART |
Jim Storey
|
|
|
Scheduled by a contractor via Hello! on 05/30/2002 at 14:36:38. Contact: ###-####.c/n on site maintanestair and corridor / top suport walls / lable saftey glazing. 5/31/2002 10:17:42 AM
|
Issue PAID IN FULL permit | | | 5/15/2002 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 5/13/2002 | | 5/14/2002 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/14/2002 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 5/14/2002 | | |
|
|
|
|
Print Occupancy Form | | | 5/14/2002 | | |
|
|
|
|
Telephone call | | | 5/14/2002 | | DONE |
|
|
|
left mess that permit is ready
|
Plan assigned to (CJW) | 4/26/2002 | | 5/14/2002 | | PASS |
Carl Westfall
|
|
|
5/14/2002 08:40:17 CJW - activity updated through activity BLDA022 from case BLD02-00978.
|
Plan Review Completed(1st rev) | | | 5/13/2002 | | PASS |
|
|
|
|
Routing - FIRE | 5/8/2002 | | 5/13/2002 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 4/29/2002 | | 5/8/2002 | | PASS |
|
|
|
UBC plan review started May 7, 2002 and finished the next day. The drawings were approved with conditions. See the conditions list.
|
Routing - PUBLIC WORKS | 4/26/2002 | | 4/29/2002 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 4/24/2002 | | |
|
|
|
|
Application received | | | 4/24/2002 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 4/24/2002 | | DONE |
|
|
|
|