Permit Information
Permit NumberBLD02-01218
StatusFinaled
Name ST LUKES
Site Address 1000 E PARK BLVD
Project Name 
Customer NumberSTL210523
ePlanReviewNo
Description
"WAREHOUSE STORAGE, NEW OVERHEAD DOOR & EXIT ACCESS UPGRADE" Within the existing 42,000 sq. ft building, add a new overhead door and new exit access door with landings within a 26,400 sq. ft. warehouse storage area. Work includes cutting out an 10'-8" high by 11'-4" wide portion of the existing masonry wall to allow installation of a new overhead door per engineering and plans. NOTE: Existing bond beam over new opening to remain in place. Existing roof truss system runs parallel to the new opening. To install bracing at top of existing CMU wall per plan. To upgrade exit system by installing appropriate landing on both sides of a minimum 3'-0" x 6'-8" man door to be located in the NW corner of the storage warehouse, a location of a previous exit door. To add hand rails as required at all stairs & ramps; verify exit door hardware, exit signage & illumination; verify draft stops in attic and sprinkler & alarm system throughout building. NOTE: The sprinkler system is required for allowable area increase for code compliance of existing building. SPECIAL INSPECTION REQUIRED FOR EPOXY CONNECTIONS & WELDING INDICATED ON SHEET S1.0 of approved plans. PC#02-323/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection2/27/20032/27/20032/27/2003 PASS
DetailsDave Hannah
DOC - Permit Expired2/27/20032/27/20032/27/2003APASS
DetailsDave Hannah
Expired by inspector at 2/27/2003 8:44:01 AM
BLD-Final12/12/200212/17/200212/17/2002ACANC
DetailsDave Hannah
Scheduled by a contractor via Hello! on 12/12/2002 at 15:27:28. Contact: ###-####.
BLD-Final12/17/200212/17/200212/17/2002PPASS
DetailsDave Hannah
ok for perm occ all as per city aproved plans 12/17/2002 1:02:01 PM
FIRE-Final Inspection12/12/200212/12/200212/12/2002PPASS
DetailsRick Jackson
FIRE-Final Inspection12/9/200212/9/200212/9/2002AFAIL
DetailsRick Jackson
Scheduled by a contractor via Hello! on 12/09/2002 at 07:20:55. Contact: ###-####. need approved plans for fire alarm and record of completion; need map at panel 12/10/2002 10:35:06 AM
FIRE-Conference7/16/20027/17/20027/17/2002APART
DetailsRick Jackson
dan ###-#### reviewed exit signs; emergency lights and alarm permit; exit door hardware will need to be changed 7/17/2002 4:01:25 PM
Issue & PRINT to be Invoiced  6/20/2002 DONE
Print Occupancy Form  6/18/2002 DONE
Inspection Record Card- Bld  6/18/2002 DONE
Telephone call  6/18/2002 DONE
permit ready
Plan assigned to (DRS)5/17/20025/17/20026/17/2002 PASS
DetailsDan Stuart
6/17/2002 14:46:14 DRS - activity updated through activity BLDA022 from case BLD02-01218.
Routing - PLAN CHECK6/10/2002 6/17/2002 PASS
Received resubmittals from architect. Inserted into plans with note on special inspection and exit door hardware. Plans approved and per attached plan review comments. To permit desk to issue.
Plan resubmittals received  6/17/2002 DONE
Received two sets of resubmittal sheets A0.1and A2.0. Routed to Dan Stuart.
PLANS/APPL TAKEN TO FRONT DESK  6/17/2002 PASS
To permit desk for issue.
Routing - FIRE6/6/2002 6/11/2002 PASS
approved without written comment
Plan Review Completed(1st rev)  6/10/2002 FAIL
Routing - PLANNING6/5/2002 6/6/2002 PASS
Approved.
Routing - PLAN CHECK5/17/20025/17/20026/4/2002 FAIL
Curtis Weedop, SLRMC design staff, to review in the field the best means to provide a new exit directly to the exterior from the storage warehouse and provide required landings at doors; handrails at stairs; exit signs & illumination; draft stops and door hardware. Plans will be forwarded to Planning for review of new exterior modifications for doors and to fire code analyst for review of sprinkler system & alarm requirements.
Plan resubmittals requested  6/4/2002 FAIL
Copy of review comments to Gregg Ostrow - faxed & mailed. Forwarding to Planning for review and then fire code analyst.
Application received  5/17/2002  
Plans ACCEPTED BY PLAN TECH  5/17/2002 DONE