BLD-Final | 11/20/2002 | 11/21/2002 | 11/21/2002 | P | PASS |
Carl Dependahl
|
|
|
###-####...lc issued, has $4000 bond for possible variance for "overheight "retaining wall at front set-back... 11/21/02 4:02:03 PM
|
BLD-Grading Inspection | 11/21/2002 | 11/21/2002 | 11/21/2002 | | BOND |
Rita DeYoung
|
|
|
Final grading is complete and approved except for the retaining wall along the driveway. It was not built as approved and requires a variance. The contractor has submitted a $4000.00 bond to rebuild the wallas approved. Grading and drainage is conditionally approved.
|
DOC - Permit Finaled | 11/21/2002 | 11/21/2002 | 11/21/2002 | P | PASS |
Carl Dependahl
|
|
|
Finaled by inspector at 11/21/02 4:02:24 PM
|
BLD-Conference | 11/12/2002 | 11/15/2002 | 11/15/2002 | A | CANC |
Carl Dependahl
|
|
|
FRANK IHIS IS TO MAKE SURE THAT RVERY THING IS OK BEFORE A FINAL IS CALLED FOR; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
BLD-Foundation | 11/13/2002 | 11/14/2002 | 11/14/2002 | A | PART |
Carl Dependahl
|
|
|
###-####...ret wall by drive ok 11/14/02 12:40:20 PM
|
BLD-Final | 11/14/2002 | 11/14/2002 | 11/14/2002 | A | FAIL |
Carl Dependahl
|
|
|
c/n, handrails, insul & air seal...other finals, misc finish, carpet, woodstovenot finalled, courtesy inspection only.
|
BLD-Footing | 11/13/2002 | 11/13/2002 | 11/13/2002 | P | PART |
Steven Webb
|
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie wip--90% ready--retaining wall footing--per engineering. 11/13/2002 3:37:53 PM
|
BLD-Energy code compliance | 10/17/2002 | 10/18/2002 | 10/18/2002 | A | PART |
Carl Dependahl
|
|
|
ok to cover, need r-10 at bsmt concrete walls 10/18/02 5:00:34 PM
|
BLD-Energy code compliance | 10/15/2002 | 10/17/2002 | 10/17/2002 | P | CANC |
Jim Storey
|
|
|
FRANK; Phone #: ###-#### Internet Inspection Request from: Darla Downs out of time. 10/17/2002 5:25:10 PM
|
BLD-Framing/Rough-in | 10/14/2002 | 10/15/2002 | 10/15/2002 | P | PASS |
Tony Young
|
|
|
###-####
|
BLD-Framing/Rough-in | 10/7/2002 | 10/8/2002 | 10/8/2002 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 10/07/2002 at 19:12:49. Contact: ###-####.ext. shear ok, pending eng. letter 10/8/2002 12:07:02 PM
|
BLD-Framing/Rough-in | 10/4/2002 | 10/7/2002 | 10/7/2002 | A | FAIL |
Tony Young
|
|
|
frank shear wall; Phone #: ###-#### Internet Inspection Request from: Darla Downs
c/n posted 10/7/2002 11:15:00 AM
|
BLD-Foundation | 8/30/2002 | 9/3/2002 | 9/3/2002 | A | PART |
Tony Young
|
|
|
wip, ok to pour when ready 9/3/2002 11:50:01 AM
|
BLD-Foundation | 8/29/2002 | 8/30/2002 | 8/30/2002 | P | PART |
Tony Young
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
wip 9/3/2002 11:36:08 AM
|
BLD-Footing | 8/22/2002 | 8/23/2002 | 8/23/2002 | A | NR |
Dave Hannah
|
|
|
###-####
|
BLD-Foundation | 8/23/2002 | 8/23/2002 | 8/23/2002 | P | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 08/23/2002 at 10:00:38. Contact: ###-####.
|
Issue PAID IN FULL permit | | | 8/16/2002 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 7/18/2002 | 7/18/2002 | 8/15/2002 | | PASS |
Dan Overy
|
|
|
8/15/2002 14:01:47 DJO - activity updated through activity BLDA022 from case BLD02-01320.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/15/2002 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/15/2002 | | DONE |
|
|
|
|
Telephone call | | | 8/15/2002 | | DONE |
|
|
|
PERMIT READY AND FEES DUE
|
Case Summary (BLD) | | | 8/14/2002 | | PEND |
|
|
|
|
Plan Review Report | | | 8/14/2002 | | PEND |
|
|
|
|
BLD-Grading Inspection | 8/13/2002 | 8/13/2002 | 8/13/2002 | | DONE |
Rita DeYoung
|
|
|
footing subgrade has been approved by the geotechnical engineer
|
Plan Reviewer's activity | | | 7/19/2002 | | PEND |
|
|
|
foundation design. excavation permit will be issued to determine exactly where native soil conditions are located. at this time a new engineered foundation plan will be submitted. foundation plan will be drawn to scale, according to engineers design. correct elevation datumn will be incorporated. plans are being placed in pending condition. have contacted contractor (frank hurlbutt), designer (todd henry) and engineer (true engineering).
|
Plan Reviewer's activity | | | 7/18/2002 | | PEND |
|
|
|
will continue review tomorrow. will need to red-line footings and verify foundation.
|
Plans ACCEPTED BY PLAN CHECK | | | 7/18/2002 | | |
|
|
|
|
Routing - FIRE | 7/8/2002 | | 7/15/2002 | | DONE |
|
|
|
7/11/02 - No information on file. Holding for reply from Dave Miller.
7/15/02 - No fire sprinkler requirements for this subdivision, per DM.
|
Routing - PLANNING | 6/21/2002 | | 7/8/2002 | | PASS |
|
|
|
DO NOT ISSUE PERMITS UNTIL 5:00 JULY 8TH (APPEAL PERIOD)
|
Routing - PLANNING Land Div | 6/21/2002 | 6/21/2002 | 6/21/2002 | | PASS |
|
|
|
ros to locate property pins only...no change in lot lines
|
Routing - PLANNING | 6/18/2002 | | 6/21/2002 | | PEND |
|
|
|
Sent to Land Division. Sent to Susan for CFH02-00014 approval. kmm
|
Routing - PUBLIC WORKS | 6/18/2002 | | 6/18/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 5/30/2002 | | 6/18/2002 | | PASS |
Rita DeYoung
|
|
|
Approved as category 1 with with conditions of approval in letter attached to plans. 6/18/02. No foundation information. No designs for retaining walls. grading plan needs revisions.6/7/02
|
Application received | | | 5/28/2002 | | |
|
|
|
|
Routing - PLAN CHECK | 7/15/2002 | | | | |
|
|
|
|