BLD-Final | 5/8/2003 | 5/8/2003 | 5/8/2003 | A | PASS |
Dave Hannah
|
|
|
c.c # 22911 issued 5/8/2003 10:24:53 AM
|
DOC - Permit Finaled | 5/8/2003 | 5/8/2003 | 5/8/2003 | A | PASS |
Dave Hannah
|
|
|
Finaled by inspector at 5/8/2003 10:25:06 AM
|
BLD-Final | 4/30/2003 | 5/1/2003 | 5/1/2003 | A | FAIL |
Dave Hannah
|
|
|
###-#### key is in the electrical outlet at the lower left of the front door c/n on site 5/1/2003 10:31:44 AM
|
BLD-Grading Inspection | 4/8/2003 | 4/8/2003 | 4/8/2003 | | DONE |
Rita DeYoung
|
|
|
final grading and drainage approved
|
BLD-Framing/Rough-in | 11/6/2002 | 11/7/2002 | 11/7/2002 | P | PART |
Carl Dependahl
|
|
|
shear
; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung- 11/7/2002 1:53:26 PM...int gyp shear ok 11/8/2002 1:10:20 PM
|
BLD-Framing/Rough-in | 10/30/2002 | 10/31/2002 | 10/31/2002 | A | PASS |
Dave Hannah
|
|
|
grant-re-insp; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie all c/n items are completed insulation ok ok to cover 10/31/2002 11:01:29 AM
|
BLD-Conference | 10/29/2002 | 10/29/2002 | 10/29/2002 | P | PART |
Tony Young
|
|
|
GRANT APPROVED PLANS ON FIREPLACE PLEASE SEE ATTACHED ENG LETTER; Phone #: ###-#### Internet Inspection Request from: Darla Downs
recvd. eng. letter, ok to insulate, c/n still posted on some 10/29/2002 4:14:08 PM
|
BLD-Framing/Rough-in | 10/23/2002 | 10/24/2002 | 10/24/2002 | P | FAIL |
Tony Young
|
|
|
###-####
c/n posted, do not insulate 10/24/2002 2:48:48 PM
|
Case Summary (BLD) | | | 10/21/2002 | | DONE |
|
|
|
re-issue copy of permit. contractor has lost both approved sets of plans.
|
Plan Review Report | | | 10/21/2002 | | DONE |
|
|
|
re-issue condition list. contractor has lost both approved sets of plans.
|
Telephone call | | | 10/21/2002 | | DONE |
|
|
|
CALLED 10-21-02 PLANS READY TO BE PICKED UP AGAIN
|
Routing - Erosion and Sediment | 10/17/2002 | | 10/17/2002 | | PASS |
|
|
|
Approved with conditions attached to drawing.
|
Routing - PUBLIC WORKS GRADING | 10/15/2002 | | 10/16/2002 | | PASS |
Rita DeYoung
|
|
|
|
BLD-Framing/Rough-in | 10/11/2002 | 10/14/2002 | 10/14/2002 | A | PART |
Tony Young
|
|
|
shear nail - grant- ###-####-pd re-insp fee
ext. shear ok 10/14/2002 12:15:58 PM
|
BLD-Framing/Rough-in | 10/9/2002 | 10/10/2002 | 10/10/2002 | A | FAIL |
Tony Young
|
|
|
shear nailing- brent; Phone #: ###-####
reinspection fee imposed, $42, c/n posted,, no approved plans on site, 2nd time 10/10/2002 12:14:12 PM
|
BLD-Framing/Rough-in | 10/7/2002 | 10/7/2002 | 10/7/2002 | P | FAIL |
Tony Young
|
|
|
shear; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
not ready, no plans 10/7/2002 3:09:30 PM
|
BLD-Foundation | 9/6/2002 | 9/6/2002 | 9/6/2002 | P | PART |
Dave Hannah
|
|
|
jerry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie work in progress 905% complete 9/6/2002 4:37:16 PM
|
BLD-Footing | 9/4/2002 | 9/4/2002 | 9/4/2002 | P | PART |
Tony Young
|
|
|
###-####
|
BLD-Grading Inspection | 8/29/2002 | 8/29/2002 | 8/29/2002 | | DONE |
Rita DeYoung
|
|
|
Geotechnical engineer has approved the foundation subgrade.
|
Issue PAID IN FULL permit | | | 8/15/2002 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 8/2/2002 | 8/2/2002 | 8/2/2002 | | PASS |
Dan Overy
|
|
|
8/2/2002 14:04:23 DJO - activity updated through activity BLDA022 from case BLD02-01468.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/2/2002 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 8/2/2002 | | DONE |
|
|
|
|
Plan Review Report | | | 8/2/2002 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 8/2/2002 | | DONE |
|
|
|
|
Print Occupancy Form | | | 8/2/2002 | | DONE |
|
|
|
|
Telephone call | | | 8/2/2002 | | DONE |
|
|
|
permit ready and fees due
|
Plan Reviewer's activity | | | 8/2/2002 | | |
|
|
|
|
Routing - PLANNING | 6/27/2002 | | 7/25/2002 | | FAIL |
|
|
|
7/3/02-FAIL. Common driveway shown is not an approved common drive. Called and talked to Grant Kolnes.
|
Routing - Erosion and Sediment | 7/25/2002 | | 7/25/2002 | | PASS |
|
|
|
ESC plan approved with conditions attached to drawings.
|
Routing - FIRE | 7/25/2002 | | 7/25/2002 | | DONE |
|
|
|
No fire sprinklers required for this subdivision (Northridge #5)
|
Routing - PLANNING | 7/25/2002 | | 7/25/2002 | | PASS |
|
|
|
Zoning Certificate for common driveway approved.
|
Telephone call | | | 7/3/2002 | | DONE |
|
|
|
Left message for Chris Findley on his voice mail. Also left message for Scott Findley on his voice mail.
|
Routing - PUBLIC WORKS GRADING | 6/27/2002 | | 6/27/2002 | | PASS |
Rita DeYoung
|
|
|
Approved as category 3 with conditions of approval in letter attached to plans
|
Routing - PUBLIC WORKS | 6/27/2002 | | 6/27/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 6/13/2002 | | 6/21/2002 | | FAIL |
Rita DeYoung
|
|
|
Test pit logs were not included in the soils report
|
Application received | | | 6/13/2002 | | |
|
|
|
|
Pending Assignment by DJO | 6/13/2002 | | | | |
Dan Overy
|
|
|
|
Routing - PLAN CHECK | 7/25/2002 | | | | |
|
|
|
|
Routing - PLANNING | 10/16/2002 | | | | |
|
|
|
|
Routing - PLAN CHECK | | | | | |
|
|
|
|