BLD-Final | 1/6/2003 | 1/6/2003 | 1/6/2003 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 01/06/2003 at 09:52:11. Contact: . C. of C. #22422 issued. 1/6/2003 2:21:03 PM
|
DOC - Permit Finaled | 1/6/2003 | 1/6/2003 | 1/6/2003 | P | PASS |
Steven Webb
|
|
|
Finaled by inspector at 1/6/2003 2:21:08 PM
|
BLD-Final | 12/18/2002 | 12/19/2002 | 12/19/2002 | A | FAIL |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 12/18/2002 at 15:37:42. Contact: .insulate rim in crawel 12/19/2002 10:25:37 AM
|
BLD-Wall cover | 10/1/2002 | 10/2/2002 | 10/2/2002 | A | NR |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 10/01/2002 at 14:13:33. Contact: .crew still working on c/n items 10/2/2002 11:00:59 AM
|
BLD-Wall cover | 10/2/2002 | 10/2/2002 | 10/2/2002 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 10/02/2002 at 10:36:17. Contact: .
|
BLD-Wall cover | 9/30/2002 | 10/1/2002 | 10/1/2002 | A | FAIL |
Jim Storey
|
|
|
1. FIRE BLOCKING - In combustible construction fire blocking shall be provided (1) In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10-foot intervals both vertical and horizontal, (2) At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings, (3) In concealed spaces between stair stringers at the top and bottom of the run and between studs along and in line with the run of stairs if the walls under the stairs are unfinished, (4) In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials, and (5) at openings between attic spaces and chimney chases for factory-built chimneys. (1997 UBC 708.2.1) Where fire blocks are allowed to be of combustible materials, fireblocking shall consist of 2 inches nominal lumber or two thicknesses of 1-inch nominal lumber with broken lap joints or one thickness of 23/32-inch wood structural panel with joints backed by 23/32-inch wood structural panel. Fire blocks may also be gypsum board, cement fiber board, batts or blankets of mineral or glass fiber, or other approved materials installed in such a manner as to be securely retained in place. (1997 UBC 708.2.2) at entry and ceilling of fire place.
2. provide insulation at garage wall at com. cable box to meet r-value as well as dryer duct.
|
BLD-Framing/Rough-in | 9/26/2002 | 9/26/2002 | 9/26/2002 | P | PASS |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 09/26/2002 at 07:30:16. Contact: . Ok to insulate 9/26/2002 3:53:19 PM
|
BLD-Framing/Rough-in | 9/25/2002 | 9/25/2002 | 9/25/2002 | P | FAIL |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 09/25/2002 at 08:23:58. Contact: . C/N posted--Do not insulate--Mech. r.i. not done. 9/25/2002 3:24:11 PM
|
BLD-Other | 8/26/2002 | 8/27/2002 | 8/27/2002 | A | PART |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 08/26/2002 at 07:51:00. Contact: . Shear--ok to cover ext. Retrof mis-located hd -- check at framing-rear of house-marked on plans. 8/27/2002 10:33:35 AM
|
BLD-Foundation | 8/1/2002 | 8/2/2002 | 8/2/2002 | A | PART |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 08/01/2002 at 15:51:29. Contact: ###-####. wip--95% ready. Rebar in place. 8/2/2002 12:05:37 PM
|
BLD-Foundation | 8/1/2002 | 8/1/2002 | 8/1/2002 | P | PART |
Steven Webb
|
|
|
Scheduled by a contractor via Hello! on 08/01/2002 at 08:09:36. Contact: ###-####. Footing not foundation--85% ready 8/1/2002 4:22:03 PM
|
Issue PAID IN FULL permit | | | 7/19/2002 | | |
|
|
|
|
Pending Assignment by DJO | 6/19/2002 | | 7/3/2002 | | DONE |
Dan Overy
|
|
|
7/3/2002 10:16:46 SAM - activity updated through activity BLDA183 from case BLD02-01514.
|
Routing - PLAN CHECK | 6/21/2002 | | 7/3/2002 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 7/3/2002 | | 7/3/2002 | | PASS |
Steve Munroe
|
|
|
7/3/2002 13:35:14 SAM - activity updated through activity BLDA022 from case BLD02-01514.
|
Print Pending Permit.LaserJet4 | | | 7/3/2002 | | |
|
|
|
|
Plan Review Report | | | 7/3/2002 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 7/3/2002 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 7/3/2002 | | DONE |
|
|
|
|
Telephone call | | | 7/3/2002 | | DONE |
|
|
|
PERMIT READY AND FEES DUE
|
Routing - PLANNING | 6/19/2002 | | 6/20/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 6/20/2002 | | 6/20/2002 | | PASS |
|
|
|
|
Application received | | | 6/19/2002 | | |
|
|
|
|