Permit Information
Permit NumberBLD02-01612
StatusFinaled
Name THE CHILDREN'S STORE
Site Address 137 N BENJAMIN LN
Project Name 
Customer Number 
ePlanReviewNo
Description
(THE CHILDREN'S STORE) To perform minor remodel and establish a 'certificate of occupancy' for a 10,618 sq.ft. retail and storage tenant per approved plans on file. Work to include removal of a mezzanine and stairs there to; to modify two (2) restrooms for full accessibility compliance; to provide code upgrades for life safety items; and install steel racks with anchors & beam labeling per engineering; to install draft stops from floor to roof deck at maximum 100 ft spacing; per attached plan review comments / conditions, notes on plans, all part of the approved plans requiring compliance. NOTE: This building is fully sprinklered. PC#02-414/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Fee Review-notes7/2/20027/2/20028/10/2004 DONE
fire permit issued
First Notice 9/10/20039/10/2003 DONE
Permanent occupancy  8/21/2003 DONE
Perm. Occ. Cert. #9770 issued 8-21-03 to the Children's Store
Permanent Occupancy 8/20/20038/20/2003 DONE
Details
BLD-Final8/19/20038/20/20038/20/2003APASS
DetailsRuss Owen
austin; Phone #: ###-#### Internet Inspection Request from: Darla Downs Ok perm oc. 8/20/2003 11:34:31 AM
BLD-Final8/18/20038/19/20038/19/2003AFAIL
DetailsRuss Owen
AUSTIN; Phone #: ###-#### Internet Inspection Request from: Darla Downsneed to attach fasteners to studs at shelves went over this with austin. 8/19/2003 10:52:39 AM
BLD-Final8/1/20038/1/20038/1/2003PNR
DetailsRuss Owen
jefferson; Phone #: ###-#### Internet Inspection Request from: Barbara MooreNew plans wanted some screws at 6 foot metal shelves to walls went over plan with person on site. 8/1/2003 4:09:33 PM
BLD-Final7/30/20037/31/20037/31/2003AFAIL
DetailsRuss Owen
Scheduled by a contractor via Hello! on 7/30/2003 at 3:01:02 PM. . needs some bolts in floor plates. 7/31/2003 1:53:56 PM
FIRE-Final Inspection7/28/20037/29/20037/29/2003APASS
DetailsTroy Cobbley
fire life safety finaled 7/29/2003 11:51:53 AM
BLD-Final7/28/20037/29/20037/29/2003PPART
DetailsRuss Owen
###-#### austin, C/n given to tennant for bolting racks to floor, lower restroom mirror, remove t-bar ceiling or repair in break room area. Ok for a temp oc.7/29/2003 5:35:46 PM 7/29/2003 5:35:58 PM
BLD-Framing/Rough-in6/16/20036/17/20036/17/2003APASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 6/16/2003 at 1:05:53 PM. Contact: ###-####.
FIRE-Final Inspection6/16/20036/17/20036/17/2003AFAIL
DetailsTroy Cobbley
austin; Phone #: ###-#### The inspection was for the fire sprinkler portion of the permit. Pendant sprinklers are overspace in numerous locations in the merchandizing areas.A sprinkler pendant needs to be provided in the closet or the ceiling is to be removed. Tire storage in the wharehouse to be less than 5'. Wood storage to be less than 10'. I could not verify a minimum .2 gpm over 130 sq. ft. density sprinkler design as the sticker on the riser is missing. I went over some life safety issues with the tenant 6/17/2003 2:02:30 PM
BLD-Framing/Rough-in5/15/20035/15/20035/15/2003PPASS
DetailsRuss Owen
austin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore.ok to cover bathroom. 5/15/2003 4:44:38 PM
BLD-Framing/Rough-in4/21/20034/21/20034/21/2003PPART
DetailsRuss Owen
austin; Phone #: ###-#### Internet Inspection Request from: Annette Moore. needs to complete misc in left rest room other ok. 4/21/2003 3:36:37 PM
BLD-Wall cover4/17/20034/18/20034/18/2003PFAIL
DetailsRuss Owen
austin; Phone #: ###-#### Internet Inspection Request from: Annette Moore. needs electrical insp and shore up 1 area over rest room went over this with Austin told him to recall when done. 4/18/2003 3:58:41 PM
BLD-Conference3/19/20033/20/20033/20/2003PPART
DetailsRuss Owen
JEANNE; Phone #: ###-#### Internet Inspection Request from: Annette Moore. went over front ddoors 3/20/2003 4:43:26 PM
Additional plans submitted  3/3/2003 PASS
Tenant wants to use two doors originally indicated as exit doors only with the existing set double doors located at center of tenant space as the main entry. Okay to modify the original layout as long as exit doors have automatic flush bolts on inactive leaf with all door hardware removed and the panic hardware complys with code section 1003.3.1.9, all as allowed by section 1003.3.1.8, exception #3. The remaining leaf will look identical to the active leaf except for hardware and therefore cannot be locked shut against use. Exit signage and illumination to be per section 1003.3.2.10 & 1003.3.2.11, 2000 IBC. Verify all changes for compliance in the field with the fire and structural inspectors.
Inspection Record Card- Bld  2/7/2003 DONE
Print Occupancy Form  2/7/2003 DONE
Telephone call  2/7/2003 DONE
called 2-7-03
Issue PAID IN FULL permit  2/7/2003 DONE
Plan assigned to (DRS)7/3/2002 2/6/2003 PASS
DetailsDan Stuart
2/6/2003 15:30:25 DRS - activity updated through activity BLDA022 from case BLD02-01612.
Routing - PLAN CHECK2/5/2003 2/6/2003 PASS
Plans approved based on resubmittal comments of 2/5/03 & red-line comments from plan review concerning the door hardware requirements and the attachement of the steel racks to the floor per engineering and wood shelf attachment to the walls per the architect call out. Plan review comments, architects & engineers responses also included with and as part of the approved plans requiring compliance for the tenant to obtain a certificate of occupancy.
PLANS/APPL TAKEN TO FRONT DESK  2/6/2003 PASS
To permit desk to issue. New certificate of value provided - from $2,500.00 to $4,000.00.
Plan resubmittals received  2/5/2003 DONE
Received two copies of resubmittal sheets A-1 with (1) Comment Memorandum, (1) TI Application, (1) Rack Calculations and transmittal. Routed to Dan Stuart.
Routing - PLAN CHECK7/22/2002 12/30/2002 FAIL
Resubmittals & clarifications of 12/23/02 incomplete. Fax sent to Tim Perry, BRS architects stating remaining items needed submitted.
Plan resubmittals requested  12/30/2002 FAIL
Plan modifications submitted make changes to scope of work; application and certificate of value that require additional new submittals. Copy of corrections & clarifications required faxed & mailed to architect.
Plan resubmittals received  12/23/2002 DONE
Received two copies of revised floor plans sheet A-1 onew copy of Stapley engineering pallet rack study and one copy of DeBest fire protection system analysis letter. Routed to Dan S. kmm
Plan Review Completed(1st rev)  7/22/2002 FAIL
Routing - FIRE7/17/2002 7/22/2002 PASS
Plan resubmittals requested  7/17/2002 FAIL
Copy of plan review comments requiring response from architect faxed and mailed to Tim Perry, BRS.
Routing - PLAN CHECK7/3/2002 7/17/2002 FAIL
Clarifications & resubmittals required. To fire code analyst while waitng for architects response.
Plans ACCEPTED BY PLAN TECH  7/2/2002 DONE
Application received  7/2/2002  
Recd Pcfee & Taken To Pln CK  7/2/2002 DONE