BLD-Final | 6/17/2003 | 6/18/2003 | 6/18/2003 | A | PASS |
Tony Young
|
|
|
robert; Phone #: ###-#### Internet Inspection Request from: Annette Moore
|
DOC - Permit Finaled | 6/18/2003 | 6/18/2003 | 6/18/2003 | P | PASS |
Tony Young
|
|
|
Finaled by inspector at 6/18/2003 11:54:51 AM
|
BLD-Final | 6/13/2003 | 6/17/2003 | 6/17/2003 | A | FAIL |
Steven Webb
|
|
|
ROBERT; Phone #: ###-#### Internet Inspection Request from: Darla Downs C/N on site. 6/17/2003 9:20:36 AM
|
BLD-Grading Inspection | 6/17/2003 | 6/17/2003 | 6/17/2003 | | PASS |
Rita DeYoung
|
|
|
Final grading and drainage is approved.
|
BLD-Energy code compliance | 3/10/2003 | 3/11/2003 | 3/11/2003 | P | PASS |
Tony Young
|
|
|
robert; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Framing/Rough-in | 3/4/2003 | 3/7/2003 | 3/7/2003 | A | PASS |
Tony Young
|
|
|
ROBERT; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ok to insulate 3/7/2003 11:46:36 AM
|
BLD-Framing/Rough-in | 2/24/2003 | 2/25/2003 | 2/25/2003 | A | PART |
Tony Young
|
|
|
shear\\call first; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
ext. shear ok 2/25/2003 1:16:12 PM
|
BLD-Framing/Rough-in | 2/21/2003 | 2/24/2003 | 2/24/2003 | A | FAIL |
Carl Dependahl
|
|
|
###-####...c/n: clarify if eng'd or city "conditions"...need int sheathed 2/24/2003 9:41:25 AM
|
BLD-Framing/Rough-in | 2/21/2003 | 2/21/2003 | 2/21/2003 | P | CANC |
Tony Young
|
|
|
###-####; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
|
BLD-Framing/Rough-in | 2/18/2003 | 2/19/2003 | 2/19/2003 | A | FAIL |
Tony Young
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
need to finish 2nd floor straps, nailing 2/19/2003 9:53:39 AM
|
BLD-Framing/Rough-in | 2/5/2003 | 2/10/2003 | 2/10/2003 | A | PART |
Tony Young
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
conference only, not a formal inspection, nothing passed for cover 2/10/2003 12:04:30 PM
|
BLD-Foundation | 10/28/2002 | 10/29/2002 | 10/29/2002 | A | PART |
Tony Young
|
|
|
brent; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Footing | 10/24/2002 | 10/24/2002 | 10/24/2002 | P | PART |
Tony Young
|
|
|
larry late pm; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
|
BLD-Grading Inspection | 10/23/2002 | 10/23/2002 | 10/23/2002 | | DONE |
Rita DeYoung
|
|
|
Footing subgrade has been approved by the geotechnical engineer
|
BLD-Footing | 10/22/2002 | 10/23/2002 | 10/22/2002 | P | CANC |
Tony Young
|
|
|
###-#### INSPECTION CANC WILL CALL WHEN READY...
|
Plan assigned to (DJO) | 10/9/2002 | 10/9/2002 | 10/22/2002 | | PASS |
Dan Overy
|
|
|
10/22/2002 08:08:47 DJO - activity updated through activity BLDA022 from case BLD02-02043.
|
Plan Reviewer's activity | | | 10/22/2002 | | DONE |
|
|
|
received revised plans and calculations on 10/21/2002. ok to issue permit
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/22/2002 | | DONE |
|
|
|
|
Plan Review Report | | | 10/22/2002 | | DONE |
|
|
|
|
Plan assigned to (DJO) | 8/27/2002 | | 10/22/2002 | | PASS |
Dan Overy
|
|
|
|
Inspection Record Card- Bld | | | 10/22/2002 | | |
|
|
|
|
Print Occupancy Form | | | 10/22/2002 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 10/22/2002 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 10/16/2002 | | 10/22/2002 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN CHECK | | | 10/16/2002 | | PEND |
|
|
|
ESC approved per Jim Rodgers. Lars Hansen (designer) has picked up 2nd set of plans. Corrections to plans, engineers stamp and all items on check list will be addressed before issuance.
|
Routing - Erosion and Sediment | 10/15/2002 | | 10/16/2002 | | PASS |
|
|
|
ESC Plan approved with conditions attached to plans.
|
Plan Reviewer's activity | | | 10/15/2002 | | DONE |
|
|
|
spoke with Lars Hansen about additional information that is required. One set of plans, structural engineering and correction list will be picked up for revisions. The other set along with routing papers will be sent back to Jim Rodgers to review ESC plans. If ESC passes, plans will then be re-routed to plan review.
|
Routing - PLAN CHECK | 9/30/2002 | | 10/15/2002 | | PEND |
|
|
|
Must re-route to ESC before permit can be issued. kmm
|
Plans ACCEPTED BY PLAN CHECK | | | 10/9/2002 | | |
|
|
|
|
Plan Reviewer's activity | | | 10/9/2002 | | PEND |
|
|
|
have completed review and still need additional information. will contact contractor/engineer/designer.
|
Routing - PUBLIC WORKS GRADING | 9/25/2002 | | 10/4/2002 | | PASS |
Rita DeYoung
|
|
|
Approved as Category 3 with hold on permit issuance until approval for offsight grading is submitted. Offsite grading was eliminated and developer gave permission for connection of foundation drain to the sub storm drain in common area.
|
Routing - Erosion and Sediment | 9/26/2002 | | 9/30/2002 | | FAIL |
|
|
|
ESC Plan does not meet standards of BCC 8-17 or PD Manual Appendix A & C.
Notified Plan Designer on 9/30 of failure.
|
Routing - FIRE | 9/30/2002 | | 9/30/2002 | | DONE |
|
|
|
No fire sprinklers required (Arrowhead Canyon)
|
Routing - PLANNING | 9/25/2002 | | 9/26/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 9/25/2002 | | 9/25/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS GRADING | 8/27/2002 | | 8/28/2002 | | FAIL |
Rita DeYoung
|
|
|
grading across property line and discharging foundation drains into common area. Left message with contractor asking for letter granting permission.
|
Application received | | | 8/27/2002 | | |
|
|
|
|