Permit Information
Permit NumberBLD02-02216
StatusExpired
Name LAM RESEARCH
Site Address 9939 W EMERALD ST
Project NameWESTPARK BLD "C"
Customer Number 
ePlanReviewNo
Description
(LAM RESEARCH)(WESTPARK BLD "C") To remodel an existing 6,827 sq.ft. office tenant by converting 2 offices into one 650 sq.ft. conference room per approved plans on file. Work to involve construction of interior noncombustible partitions installation of double doors and safety glazing sidelights. NOTE: This building is fully fire sprinklerd any alterations or modifications to the fire sprinkler heads shall be per NFPA #13 as regulated by the fire department. (pc#602-02) rmh
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection3/31/20093/31/20093/31/2009 CANC
DetailsMike Jordan
DOC - Permit Expired3/31/20093/31/20093/31/2009PPASS
DetailsMike Jordan
BLD-Aging Inspection9/5/20089/5/20089/12/2008 PASS
DetailsTroy Cobbley
This tenant is no longer here. The life safety was passed under the inspection for the new tenant.
BLD-Aging Inspection10/29/200710/29/200711/5/2007 PEND
DetailsMike Jordan
BLD-Aging Inspection5/18/20075/18/20075/21/2007 CANC
DetailsMike Jordan
BLD-Aging Inspection3/9/20073/9/20073/12/2007 PEND
DetailsMike Jordan
BLD-Aging Inspection11/16/200611/16/200611/16/2006 PEND
DetailsMike Jordan
BLD-Aging Inspection8/23/20068/23/20068/23/2006 PEND
DetailsMike Jordan
BLD-Aging Inspection6/12/20066/12/20066/13/2006 PEND
DetailsMike Jordan
waiting on life/safety hissues.
BLD-Aging Inspection3/27/20063/27/20064/3/2006 NR
DetailsTroy Cobbley
Correction notice was given lady at front. Notice stated that the fire alarm monitoring system shall be upgraded as per the original correction notice. Work is to be started by 4/10/06.
Plan Reviewer's activity  3/17/2003 DONE
per letter of agreement signed by DM, FD approval granted to postpone requirement to upgrade the fire alarm system until the next tenant or March 1, 2004, whichever is earlier. S.Rogers
FIRE-Final Inspection11/28/200211/29/200211/29/2002AFAIL
DetailsTroy Cobbley
repair exit sign and provide upgraded fire sprinkler monitoring system meeting current code requirements 11/29/2002 11:24:06 AM
BLD-Framing/Rough-in11/5/200211/5/200211/5/2002PPASS
DetailsRuss Owen
Scheduled by a contractor via Hello! on 11/05/2002 at 07:45:55. Contact: ###-####.
Issue PAID IN FULL permit  10/1/2002 DONE
Plan assigned to (R_H)9/23/2002 9/27/2002 PASS
Details
9/27/2002 10:04:51 RMH - activity updated through activity BLDA022 from case BLD02-02216.
Routing - PLAN CHECK9/23/2002 9/27/2002 DONE
Case Summary (BLD)  9/27/2002 DONE
Application received  9/27/2002 DONE
PLANS/APPL TAKEN TO FRONT DESK  9/27/2002 DONE
Inspection Record Card- Bld  9/27/2002 DONE
Telephone call  9/27/2002 DONE
CALLED LEFT MESSAGE FOR STAN PERMIT READY 9-27-02 ///DLD
Plans ACCEPTED BY PLAN TECH  9/13/2002 DONE
Application received  9/12/2002  
Recd Pcfee & Taken To Pln CK  9/12/2002 DONE
FIRE-Conference4/3/20064/10/2006 P 
DetailsTroy Cobbley
Follow-up on correction notice. One week was given to start work ending on 4/10/06.
Fee Review-notes9/12/20029/12/2002   
marked with no fire but they have a fire permit same on ele