Case Summary (BLD) | | | 2/29/2008 | | DONE |
|
|
|
|
(F) Reprint permit | | | 1/30/2008 | | |
|
|
|
|
Case Summary (BLD) | | | 1/24/2008 | | DONE |
|
|
|
|
Fee Review-notes | 8/13/2003 | 8/13/2003 | 8/13/2003 | | DONE |
|
|
|
|
FIRE-Final Inspection | 5/2/2003 | 5/5/2003 | 5/5/2003 | A | PASS |
Troy Cobbley
|
|
|
jim; Phone #: ###-#### Fire life safety finaled 5/5/2003 8:21:06 AM
|
BLD-Final | 5/5/2003 | 5/5/2003 | 5/5/2003 | P | PASS |
Jim Sly
|
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Barbara Moore OK for Perm Occ. :) 5/5/2003 1:10:05 PM
|
Permanent occupancy | | | 5/5/2003 | | DONE |
|
|
|
Perm. Occ. Cert. #9641 issued 5-5-03 to Allstate Insurance.
|
FIRE-Final Inspection | 5/1/2003 | 5/1/2003 | 5/1/2003 | P | FAIL |
Rick Jackson
|
|
|
exit signs not working in lobby exit and door to lobby 5/1/2003 3:47:32 PM
|
Agreement of Future work | 3/13/2003 | | 5/1/2003 | | PASS |
|
|
|
Applicant agrees to upgrade alarm system by 5-1-03 for TCO now (3-13-03).
|
Permanent Occupancy | | 4/5/2003 | 4/5/2003 | | DONE |
|
|
|
|
Meeting | | | 3/17/2003 | | DONE |
|
|
|
Letter dated 3/11/03 from Stacy Wirick, Park Pointe Prop Mgr requesting TOC for this Permit, with commitment to install FA upgrade by May 1, 2003; approved for TOC by DM, FD.
|
Telephone call | | | 3/7/2003 | | DONE |
|
|
|
Telcon from Mike at Security Group re requirements for HVAC DD monitoring. 6 DD's exist on supply side, installed under BLD96-2744. No monitoring or remote LED's provided. ANS: It appears that monitoring and remote LED were not required under Codes applied at time of installation. No modifications made to units under this permit (no mech contract); therefore not necessary to upgrade HVAC DD's to current code. Mike indicated for good practice he will tie the existing DD's into the FACP since it has adequate zone capacity and the wiring will be inexpensive to install, in conjuction with upgrading the FAC panel to include a SD over it, a MPS and proper battery supply.
|
FIRE-Final Inspection | 2/4/2003 | 2/4/2003 | 2/4/2003 | P | FAIL |
Troy Cobbley
|
|
|
###-#### Fire alarm system still needs to be taken care of per the correction notice 2/4/2003 1:38:38 PM
|
FIRE-Final Inspection | 12/12/2002 | 12/13/2002 | 12/13/2002 | A | FAIL |
Troy Cobbley
|
|
|
verify that the existing fire alarm monitoring panel meets current code or provide city approved drawings and a upgraded system, sprinkler heads in the file room are space per light hazard. They must be spaced for ordinary hazard. 12/13/2002 11:08:59 AM
|
BLD-Final | 12/12/2002 | 12/13/2002 | 12/13/2002 | A | FAIL |
Jim Sly
|
|
|
: ) Need fire Dept insp. : ) 12/13/2002 11:34:59 AM
|
CHANGE STATUS TO (ISS) | | | 12/12/2002 | | |
|
|
|
|
BLD-Framing/Rough-in | 12/5/2002 | 12/6/2002 | 12/6/2002 | A | FAIL |
Jim Sly
|
|
|
ceiling insp=odie; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Ceiling 12/6/2002 4:46:23 PM
|
BLD-Framing/Rough-in | 11/15/2002 | 11/15/2002 | 11/15/2002 | P | PASS |
Jim Sly
|
|
|
odie; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
Issue PAID IN FULL permit | | | 11/8/2002 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 10/9/2002 | | 10/10/2002 | | PASS |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 10/10/2002 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 10/10/2002 | | DONE |
|
|
|
|
Print Occupancy Form | | | 10/10/2002 | | DONE |
|
|
|
|
Telephone call | | | 10/10/2002 | | DONE |
|
|
|
called wes plans ready 10-10-02///dld
|
Plan assigned to (CJW) | 9/24/2002 | | 10/10/2002 | | PASS |
Carl Westfall
|
|
|
10/10/2002 09:24:09 CJW - activity updated through activity BLDA022 from case BLD02-02303.
|
Routing - FIRE | 10/7/2002 | | 10/9/2002 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 9/25/2002 | | 10/7/2002 | | PASS |
|
|
|
UBC plan review started October 3, 2002 and finished October 7, 2002. The drawings were approved with conditions. See the conditions list.
|
Routing - PUBLIC WORKS | 9/24/2002 | | 9/24/2002 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 9/23/2002 | | DONE |
|
|
|
|
First Notice | 9/19/2002 | 9/19/2002 | 9/19/2002 | | DONE |
|
|
|
|
Application received | | | 9/19/2002 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 9/19/2002 | | DONE |
|
|
|
|