BLD-Final | 10/10/2003 | 10/10/2003 | 10/10/2003 | P | PASS |
Dave Hannah
|
|
|
Phone #: ###-#### Internet Inspection Request from: Jim Ritter c.c # 23937 issued 10/10/2003 4:08:46 PM
|
DOC - Permit Finaled | 10/10/2003 | 10/10/2003 | 10/10/2003 | P | PASS |
Dave Hannah
|
|
|
Finaled by inspector at 10/10/2003 4:08:47 PM
|
BLD-Conference | 10/6/2003 | 10/6/2003 | 10/6/2003 | P | PASS |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on
working on project, may have household items in house, ,,ok 10/6/2003 2:29:37 PM
|
BLD-Grading Inspection | 9/3/2003 | 9/3/2003 | 9/3/2003 | | PASS |
Rita DeYoung
|
|
|
Final grading and drainage approved.
|
BLD-Energy code compliance | 3/14/2003 | 3/14/2003 | 3/14/2003 | P | PASS |
Dave Hannah
|
|
|
###-####
|
BLD-Framing/Rough-in | 3/12/2003 | 3/12/2003 | 3/12/2003 | P | PASS |
Tony Young
|
|
|
###-####
ok to insulate 3/12/2003 3:14:30 PM
|
BLD-Framing/Rough-in | 3/10/2003 | 3/10/2003 | 3/10/2003 | P | FAIL |
Tony Young
|
|
|
JIM; Phone #: ###-#### Internet Inspection Request from: Darla Downs
c/n posted, need f/p permit/inspection, seal package,,, conf. on framing, ok to insulate interior walls only 3/10/2003 2:20:55 PM
|
BLD-Framing/Rough-in | 2/26/2003 | 2/27/2003 | 2/27/2003 | A | PART |
Dave Hannah
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung shear ok to cover ext need to add to retro hold downs back wall sw corner check at frame 2/27/2003 11:34:53 AM
|
BLD-Conference | 2/7/2003 | 2/11/2003 | 2/11/2003 | A | DONE |
Dave Hannah
|
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie talked about framing of round room and shear 2/11/2003 11:50:24 AM
|
BLD-Footing | 1/24/2003 | 1/24/2003 | 1/24/2003 | P | PART |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 01/24/2003 at 08:10:02. Contact: ###-####.work in progress 1/24/2003 5:05:19 PM
|
BLD-Footing | 1/13/2003 | 1/16/2003 | 1/16/2003 | P | PASS |
Dave Hannah
|
|
|
Scheduled by a contractor via Hello! on 01/13/2003 at 17:23:01. Contact: ###-####.
|
BLD-Grading Inspection | 1/15/2003 | 1/15/2003 | 1/15/2003 | | PASS |
Rita DeYoung
|
|
|
footing subgrade has been approved by the geotechnical engineer
|
Plan assigned to (DJO) | 12/12/2002 | 12/12/2002 | 12/26/2002 | | PASS |
Dan Overy
|
|
|
12/26/2002 10:21:15 DJO - activity updated through activity BLDA022 from case BLD02-02880.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/26/2002 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 12/26/2002 | | DONE |
|
|
|
|
Plan Review Report | | | 12/26/2002 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 12/26/2002 | | DONE |
|
|
|
|
Print Occupancy Form | | | 12/26/2002 | | DONE |
|
|
|
|
Telephone call | | | 12/26/2002 | | DONE |
|
|
|
permit ready and fees due
|
Issue PAID IN FULL permit | | | 12/26/2002 | | |
|
|
|
|
Plan Reviewer's activity | | | 12/13/2002 | | |
|
|
|
after furthur review, grading and drainage plans do not have design criteria submitted from Richard W. Reed (GeoE). Briggs engineering does not apply to this project. Merlin W. Phillips (ME) has stamped foundation plans but has not provided any calculations or sections for design. Beings that additional holdowns and larger footings are indicated, calculations will be required. Wall bracing calculations will also be required.
|
Plans ACCEPTED BY PLAN CHECK | | | 12/12/2002 | | |
|
|
|
|
Plan Reviewer's activity | | | 12/12/2002 | | DONE |
|
|
|
plans not complete. have contacted designer and engineer. need additional bearing resolved, manufactured truss layout, wall bracing calculations, foundation design and detail specifying re-inforcing, special wall construction and detail on handstacked 2X12 over tower.
|
Routing - Erosion and Sediment | 12/10/2002 | | 12/10/2002 | | PASS |
|
|
|
ESC approved with conditions attached to plans.
|
Routing - PLAN CHECK | 12/4/2002 | | 12/10/2002 | | |
|
|
|
|
Routing - FIRE | 12/1/2002 | | 12/4/2002 | | DONE |
|
|
|
No fire sprinklers required (HIghlands #25 subdivision)
|
Routing - Erosion and Sediment | 12/1/2002 | | 12/2/2002 | | FAIL |
|
|
|
ESC plan does not meet requirements of BCC 8-17 and Plan Designer Manual Appendix A & C. Does not contain a schedule of BMP installation, or a RP check list. Does not show BMP protection between subject property and home to east of planned job. Letter sent to plan designer on 12/02/02.
|
Routing - PLANNING | 11/27/2002 | | 12/2/2002 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 11/27/2002 | | 11/27/2002 | | PASS |
|
|
|
NORTHWEST BOISE SEWER DISTRICT
|
Routing - PUBLIC WORKS GRADING | 11/25/2002 | | 11/27/2002 | | PASS |
Rita DeYoung
|
|
|
Approved as Category 3 with conditions of approval in letter attached to plans and this case.
|
Application received | | | 11/25/2002 | | |
|
|
|
|
Pending Assignment by DJO | 11/25/2002 | | | | |
Dan Overy
|
|
|
|
Routing - PLAN CHECK | 12/10/2002 | | | | |
|
|
|
|