Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD02-03101
StatusFinaled
Name DELI GEORGE
Site Address 101 S CAPITOL BLVD Unit: 102
Project NameUS BANK-1ST FLR
Customer Number 
ePlanReviewNo
Description
(DELI GEORGE - 1ST FLOOR) This building is fire sprinklered because it is a high-rise. To remodel a 390 square foot area for a new deli restaurant. This space is located in the Northwest corner of the first floor (14,600 square feet) in an existing high-rise building. The previous tenant was also a restaurant. Selective demolition is covered under this permit. Work is to include interior nonbearing walls, millwork, a Class II hood, suspended ceilings, and finishes all per approved drawings and plan review conditions on file. The location of fire sprinkler heads shall comply with NFPA 13-1999 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  7/2/2013 DONE
FIRE-Final Inspection4/16/20034/16/20034/16/2003APASS
DetailsRick Jackson
Permanent Occupancy 4/16/20034/16/2003 DONE
Details
Permanent occupancy UNPAID FEE  4/16/2003 DONE
Perm. Occ. Cert. #9619 issued 4-16-03 to Deli George in the U.S. Bank Bldg. on the 1st floor.
BLD-Final3/20/20033/21/20033/21/2003APASS
DetailsTom Arcoraci
ok for perm 3/21/2003 3:32:55 PM
FIRE-Final Inspection3/19/20033/20/20033/20/2003APART
DetailsRick Jackson
###-#### - ok for temp. occ. only
BLD-Final3/19/20033/20/20033/20/2003PCANC
DetailsTom Arcoraci
###-####
BLD-Framing/Rough-in3/10/20033/11/20033/11/2003ANR
DetailsCarl Dependahl
DUANE; Phone #: ###-#### Internet Inspection Request from: Darla Downs
BLD-Framing/Rough-in3/11/20033/11/20033/11/2003PPART
DetailsCarl Dependahl
walls ok, need hvac for grid / tile install. 3/11/2003 4:32:58 PM
Issue PAID IN FULL permit  2/11/2003  
Inspection Record Card- Bld  2/10/2003 DONE
Print Occupancy Form  2/10/2003 DONE
Telephone call  2/10/2003 DONE
permit ready and fees due
Routing - PLUMBING2/5/2003 2/7/2003 PASS
tie flow control fitting vent to sanitary venting system, provide a p-trap at the hub drain, grease trap must be accessable for cleaning, call field inspector for a conference prior to commencing work.
Routing - PLAN CHECK2/7/2003 2/7/2003 PASS
PLANS/APPL TAKEN TO FRONT DESK  2/7/2003 PASS
Plan assigned to (CJW)1/9/2003 2/7/2003 PASS
DetailsCarl Westfall
2/7/2003 15:52:11 CJW - activity updated through activity BLDA022 from case BLD02-03101.
Routing - PLAN CHECK1/24/2003 2/5/2003  
Sent back to Plumbing.
Plan resubmittals received  2/5/2003 DONE
Received two sets of resubmittal sheets MP0.0, MP0.1, MP0.2, MP1.0, MP2.0 and transmittal. Routed to Carl Westfall.
Routing - FIRE1/22/2003 1/24/2003 PASS
Plan Review Completed(1st rev)  1/24/2003 DONE
Routing - PLAN CHECK1/14/2003 1/22/2003 PASS
UBC plan review started January 21, 2003 and finished the next day. The drawings were approved with conditions. See the conditions list.
Routing - PUBLIC WORKS1/9/2003 1/14/2003 PASS
Routing - PLUMBING1/14/2003 1/14/2003  
Failed first UPC review. 1. Grease trap must indirect into floor sink. 2. Need 3 inch waste. 3. Grease trap must be installed in floor with 3 inch floor sink for indirect wate from grease trap.
Plans ACCEPTED BY PLAN TECH  1/2/2003 DONE
First Notice12/31/200212/31/200212/31/2002 DONE
Application received  12/31/2002  
Recd Pcfee & Taken To Pln CK  12/31/2002