Permit Information
Permit NumberBLD03-00118
StatusFinaled
Name PROFESSIONAL CARPET SERVICES
Site Address 1404 W IDAHO ST Unit: 101
Project Name 
Customer Number 
ePlanReviewNo
Description
(PROFESSIONAL CARPET SERVICES) (Occupancy Use Change)To remodel a 1,650 sq.ft. portion of the main level of existing building for retail/office/storage, to include common accessible restrooms, including exterior modifications, to include: landscaping, stairs, ramp & storefront entry under DRH02-00253. New work includes framing, wall cover, electrical, plumbing, mechanical & finishes. NOTE: Upper level, 2,016 s.f. is vacant and is not approved for use or occupancy. Accessibility to this level & change of windows only approval for work to this upper level. PC#03-026/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  1/31/2008  
Second Notice BLD4/26/20054/26/20054/26/2005 DONE
First Notice has not been responded to.
First Notice Sent 8/3/20044/26/2005 DONE
Case Summary (BLD)  12/6/2004  
Permanent Occupancy 8/17/20048/17/2004 DONE
Details
DOC - Permit Finaled8/3/20048/3/20048/3/2004PPASS
DetailsTony Young
Finaled by inspector at 8/3/2004 4:02:01 PM
BLD-Aging Inspection8/2/20048/2/20048/2/2004 DONE
DetailsTony Young
Office Staff conference/action  2/9/2004 DONE
Temp. Occ. Cert. extended until 5-14-04 as per letter from Jenifer.
BLD-Final11/12/200311/12/200311/12/2003PPASS
DetailsTom Arcoraci
rob; Phone #: ###-#### Internet Inspection Request from: Annette Moore ok for perm if others have signed perm occ 11/12/2003 1:57:58 PM
Case Summary (BLD)  10/30/2003  
BLD-Final9/19/20039/19/20039/19/2003PFAIL
DetailsTom Arcoraci
left 2nd c/notice on ramp 9/19/2003 2:19:38 PM
FIRE-Final Inspection8/26/20038/26/20038/26/2003PPASS
DetailsRick Jackson
BLD-Framing/Rough-in6/16/20036/16/20036/16/2003PPART
DetailsCarl Dependahl
###-#### rory...chk rails, steps at next insp. 6/16/2003 4:45:48 PM
BLD-Framing/Rough-in6/13/20036/13/20036/16/2003PCANC
DetailsCarl Dependahl
###-#### call for access
BLD-Framing/Rough-in6/12/20036/13/20036/13/2003ACANC
DetailsTom Arcoraci
rory; Phone #: ###-#### Internet Inspection Request from: Annette Moore needs fire final 6/13/2003 8:00:38 AM
BLD-Framing/Rough-in6/13/20036/13/20036/13/2003ANH
DetailsTom Arcoraci
canc by mistake no access no one at site 6/13/2003 9:29:35 AM
Issue PAID IN FULL permit  5/8/2003  
Telephone call  5/7/2003 DONE
LEFT MESS THAT PERMIT IS READY
Routing - PUBLIC WORKS5/5/2003 5/6/2003 PASS
Louise Waldorf returned plans with approvals and new sewer use fee's.
Routing - PLAN CHECK5/6/2003 5/6/2003 PASS
Approved as noted on and attached plan review conditions.
PLANS/APPL TAKEN TO FRONT DESK  5/6/2003 PASS
To permit desk.
Inspection Record Card- Bld  5/6/2003  
Print Occupancy Form  5/6/2003  
Telephone call  5/6/2003 DONE
LEFT MESS THAT PERMIT IS READY
Plan assigned to (DRS)1/31/2003 5/6/2003 PASS
DetailsDan Stuart
5/6/2003 11:22:41 DRS - activity updated through activity BLDA022 from case BLD03-00118.
Routing Off Site -Energy1/28/2003 5/5/2003 PASS
Route off site to Eric Makela. 4/28/03 recieved copy of energy analysis of the existing structure and for the proposed tenant improvents. Based on report and work declared to be done by design professionals, the project will meet or exceed the requirements of the code for an existing building remodel. New glazing to meet current code and be double pane, to include remaining overhead doors with glass; R-30 Insulation in ceiling; R-5, 1" EPS insulation board on interior side of all exterior masonry walls (requires thermal barrier separation and flame spread rating less than or equal to 75 / smoke developement rating of 450 or less, all per chapter 26 IBC); and insulation / joint sealing of new duct work per section 803 IECC & sheet m1.0; nor new water heating service declared.
Routing - PLAN CHECK3/7/2003 5/5/2003 PEND
Inserted new plan sheets & resubmittals received 4/28/03 into original plans & entered architects responses, and clarification notes of items to be brought into code compliance if NEW, on the plan review comment sheet given to architect on 2/21/03 and red-line notes on plan sheets.. Routing to PW for re-review for added restroom, sink & drinking fountain.
Plan resubmittals received  4/29/2003 DONE
Received two sets of engineering design calcs & details from Thomas Scofield, ZGA, acting in behalf of Ryan McCaene while Ryan is out of town.
Plan resubmittals received  4/28/2003 DONE
Plan resubmittals received. New re-submittal copies of Sheets a0.01, a1.01, a1.11, a2.01, a2.11, a3.11, e2.11, energy code analysis sheet and new first time sheets a1.12, a4.11, p1.1, p1.0, en1.0 & m1.0.
Routing - PUBLIC WORKS3/6/2003 3/7/2003 PASS
Routing - FIRE3/3/2003 3/6/2003 PASS
no correction required
Plan Review Completed(1st rev)  3/6/2003 FAIL
Plan resubmittals requested  3/3/2003 FAIL
To many issues not answered on submitted plans. Prepaired general list of items needing details or added to plans to allow code review and faxed, mailed & e-mailed to architect. Routing to fire code analyst for initial review.
Routing - PLAN CHECK2/21/2003 3/3/2003 FAIL
Initital plan review failed. General list of items needing to be addressed and shown on the plans before a plan review can be done was sent to the architect. Forwarding plans to fire code analyst for initial review.
Routing - PLANNING2/10/2003 2/21/2003 PASS
Approved per DRH02-253, and as noted.
Routing - Erosion and Sediment2/6/2003 2/10/2003 PASS
ESC approved with conditions attached to plans.
Plan resubmittals requested  2/6/2003 FAIL
Copy of energy cod plan review received from Eric Makela. Plans failed. Eric provided copy of additional information required to the design professional.
Routing - PUBLIC WORKS1/31/2003 2/6/2003 FAIL
No plumbing plans or site investigation documentation on ouside down ramp drain and interior sump connections per conversations with Ryan. Per Walt Baumgartner. Requires street light plan per Bill Colson. kmm
Plans ACCEPTED BY PLAN TECH  1/31/2003 DONE
Received two copies of ESC plans and narrative, put with plans. kmm
Plans ACCEPTED BY PLAN TECH  1/29/2003 PEND
Applicant may want an interior demo. Told him that a revised cert. reflecting demo. and a cert. for demo would be required. Arch. is working on submitting ESC plan. kmm
Plans ACCEPTED BY PLAN TECH  1/28/2003 FAIL
Contacted Arch. about COM check-EZ software must be incorporated into the plans- not just attached, have asked for three copies of plan sheets. Jim Rogers is requiring ESC plan and permit, have asked for two copies of ESC plan and faxed application to Mr. McCaene. Arch./Eng. form needs to be signed. kmm Received COM check-EZ sheets.
Application received  1/27/2003  
Recd Pcfee & Taken To Pln CK  1/27/2003 DONE
Fee Review-notes1/27/20031/27/2003