Fee Review-notes | 1/29/2003 | 1/29/2003 | 4/23/2004 | | DONE |
|
|
|
value came in at 200,000.00 permit was split into shell, grading & TI.
Sub values okay. adh.
|
FIRE-Final Inspection | 7/8/2003 | 7/9/2003 | 7/9/2003 | A | PASS |
Troy Cobbley
|
|
|
fire life safety finaled 7/9/2003 8:55:28 AM
|
BLD-Final | 7/8/2003 | 7/9/2003 | 7/9/2003 | P | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 7/8/2003 at 2:56:45 PM. Contact: ###-####.
|
DOC - Permit Finaled | 7/9/2003 | 7/9/2003 | 7/9/2003 | P | PASS |
Jim Sly
|
|
|
Finaled by inspector at 7/9/2003 3:07:32 PM
|
FIRE-Final Inspection | 7/1/2003 | 7/2/2003 | 7/2/2003 | A | CANC |
Troy Cobbley
|
|
|
###-#### ###-#### Contractor is not ready. Still waiting on door hardware 7/2/2003 11:04:45 AM
|
BLD-Conference | 7/2/2003 | 7/2/2003 | 7/2/2003 | P | DONE |
Jim Sly
|
|
|
###-#### call for a phone conference
|
FIRE-Conference | 7/1/2003 | 7/1/2003 | 7/1/2003 | P | DONE |
Troy Cobbley
|
|
|
at 3pm ###-#### I spoke with the contractor about life safety items. The door hardware on the rear exits and the restrooms is not approved type. And needs to be changed out. 7/1/2003 3:49:38 PM
|
BLD-Other | 5/23/2003 | 5/23/2003 | 5/23/2003 | A | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 5/23/2003 at 7:04:10 AM. Contact: ###-####. Truss rocked for draftstop.......Need to inspect for complying door at final. (Draftstop not shown on appr plan). 5/23/2003 12:25:52 PM
|
BLD-Energy code compliance | 5/21/2003 | 5/22/2003 | 5/22/2003 | A | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 5/21/2003 at 12:41:03 PM. Contact: ###-####.
|
BLD-Framing/Rough-in | 5/20/2003 | 5/20/2003 | 5/20/2003 | P | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 5/20/2003 at 11:14:02 AM. Contact: ###-####. 5/20/2003 1:19:16 PM
|
BLD-Other | 4/24/2003 | 4/24/2003 | 4/24/2003 | P | PART |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 4/24/2003 at 8:36:14 AM. Contact: ###-####. Shear OK. 4/24/2003 4:53:43 PM
|
BLD-Foundation | 4/4/2003 | 4/4/2003 | 4/4/2003 | P | PASS |
Jim Sly
|
|
|
manual; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
BLD-Footing | 4/3/2003 | 4/3/2003 | 4/3/2003 | P | PASS |
Russ Owen
|
|
|
###-####The approved plans indicated a 3500 psi concrete design, I asked the contractor if he had anything taht stated a lower design strength he handed me a lettter from the architect that read 3000 to 3500 psi would meet the specifications for the enguneering calculations, The engineer called back and said 2500 psi is ok. Then I went to sign the job card which was in a folder that was handed to me by the contractor with the stamped enginneering cals they clearly indicated 2500 psi. I then told the contractor to allway keep all information with plans . As this all could have been avoided. I spent almost an hour on a 2500 sq ft foundation inspection. 4/3/2003 4:54:05 PM
|
(F) Reprint permit | | | 3/18/2003 | | |
|
|
|
|
(F) Reprint permit | | | 3/18/2003 | | |
|
|
|
|
Telephone call | | | 3/17/2003 | | DONE |
|
|
|
LEFT MESS THAT PERMIT IS READY
|
Issue PAID IN FULL permit | | | 3/17/2003 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 3/12/2003 | | PASS |
|
|
|
|
Inspection Record Card- Bld | | | 3/12/2003 | | DONE |
|
|
|
|
CHANGE STATUS TO (PND) | | | 3/12/2003 | | |
|
|
|
john menard has the plans
|
Plan assigned to (JCM) | 1/30/2003 | | 3/12/2003 | | PASS |
John Menard
|
|
|
3/12/2003 14:44:39 JCM - activity updated through activity BLDA022 from case BLD03-00133.
|
Routing - PLAN CHECK | 3/5/2003 | | 3/10/2003 | | |
|
|
|
|
Routing - PUBLIC WORKS | 3/10/2003 | | 3/10/2003 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 3/10/2003 | | 3/10/2003 | | PASS |
|
|
|
|
Routing - FIRE | 2/28/2003 | | 3/5/2003 | | PASS |
|
|
|
|
Routing - PLUMBING | 2/26/2003 | | 2/28/2003 | | PASS |
|
|
|
per plans and 2000 upc
|
Routing - PLAN CHECK | 2/19/2003 | | 2/26/2003 | | |
|
|
|
|
Plan resubmittals received | | | 2/25/2003 | | DONE |
|
|
|
Received four sets of resubmittal sheets C1, A2, A4, A5, A8, A9, A10 with cover/comment letter. Routed to John Menard.
|
Plan resubmittals received | | | 2/25/2003 | | DONE |
|
|
|
Received four sets of resubmittal sheet C2.0, (1) United Water Letter, and cover/response letter addressed to Richard Dailey. Routed to John Menard.
|
Plan resubmittals received | | | 2/25/2003 | | DONE |
|
|
|
Received four sets of resubmittal sheets A10 with cover/response letter addressed to Bill VanDeGrift. Routed to John Menard.
|
Plan resubmittals received | | | 2/25/2003 | | DONE |
|
|
|
Received four sets of resubmittal sheets A9 and A10, (4) Heat Load Calc. Sheet, and cover/response letter addressed to Eric Makela. Routed to John Menard.
|
Routing - PUBLIC WORKS | 2/14/2003 | | 2/19/2003 | | PASS |
|
|
|
Send plans to PW after Plumbing review. dkl
|
Plan Review Completed(1st rev) | | | 2/14/2003 | | FAIL |
|
|
|
|
Routing - FIRE | 2/13/2003 | | 2/14/2003 | | FAIL |
|
|
|
WATER QUOTE & HYDRANT LOCATION
|
Routing - PLAN CHECK | 2/10/2003 | | 2/13/2003 | | FAIL |
|
|
|
|
Plan resubmittals requested | | | 2/13/2003 | | |
|
|
|
Mailed the architect a copy of the plan review comment list requesting revisions. JCM
|
Routing Off Site -Energy | 1/31/2003 | | 2/12/2003 | | FAIL |
|
|
|
Contacted outside energy reviewer for pickup on 1/30/03. kmm Received a fax from the energy reviewer indicating that he had sent a fax to the architect requesting revisions. JCM
|
Routing - PLUMBING | 2/6/2003 | | 2/10/2003 | | FAIL |
|
|
|
please provide a plumbing piping plan addressing the above listed items, you'll need a drip pan under the the water heater with a drain, if you install an r.p. at the service you will need to locate an indirect waster receptor under it to recieve the full discharge.
|
Routing - PLANNING | 2/5/2003 | | 2/6/2003 | | PASS |
|
|
|
Approved per DRH02-239.
|
Routing - Erosion and Sediment | 2/5/2003 | | 2/5/2003 | | PASS |
|
|
|
ESC approved with conditions attached to plans.
|
Routing - PUBLIC WORKS | 1/31/2003 | | 2/5/2003 | | FAIL |
|
|
|
Requires Drainage Plan per Brian Murphy.
|
Routing - PLANNING Land Div | 1/30/2003 | | 1/31/2003 | | PASS |
|
|
|
Lot 7, Block 1 Streeper Subdivision
|
Plans ACCEPTED BY PLAN TECH | | | 1/30/2003 | | DONE |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 1/30/2003 | | DONE |
|
|
|
|
Application received | | | 1/29/2003 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 1/29/2003 | | DONE |
|
|
|
|