Permit Information
Permit NumberBLD03-00539
StatusFinaled
Name AHRENS & DEANGELI
Site Address 101 S CAPITOL BLVD Unit: 601
Project NameUS BANK-6TH FLOOR
Customer Number 
ePlanReviewNo
Description
(AHRENS AND DeANGELI - 6TH FLOOR) This building is fire sprinklered because it is a high-rise. To create a 2,683 square foot office tenant space and to construct interior improvements. This space is located on the 6th floor (14,600 square feet total) of an existing high rise building. The "core" has a floor area of 2,670 square feet. The two existing "core" restrooms will be upgraded to be accessible to the disabled. Work is to include interior nonbearing walls, interior windows and doors, millwork, finishes, and suspended ceilings all per the approved drawings and plan review report on file. All new work associated with the existing elevator lobby/corridor shall comply with the 1-hr corridor provisions of the 2000 IBC. If not already existing, firesafing shall be installed at the perimeter of the floor (within this tenant space) between the floor and the spandrel glass. This permit does NOT allow occupancy of adjacent tenant areas. The location of fire sprinkler heads shall comply with NFPA 13-1999 as regulated by the Fire Department. (7-18-03) A "LETTER OF UNDERSTANDING" WAS SIGNED BY REPRESENTATIVES OF UNICO PROPERTIES (DAN PREISLER ON JUNE 17, 2003) AND THE CITY OF BOISE (TIM HOGLAND ON JUNE 19, 2003). THIS AGREEMENT ALLOWS THE PROVISIONS OF THE 2000 IBC TO BE APPLIED TO INDIVIDUAL FLOORS. IN ORDER TO APPLY THE 2000 IBC TO A FLOOR THE FIRE ALARM, FIRE SPRINKLER SYSTEM, AND HIGH-RISE LIFE SAFETY SYSTEMS ON THAT FLOOR (AND THE INFRASTRUCTURE SUPPORTING THESE SYSTEMS) MUST BE IN COMPLIANCE WITH THE 2000 IBC. **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Agreement of Future work6/19/20036/19/20036/30/2016 DONE
DetailsScott Arellano
Upgrade aggreement for sprinklers and alarm were added.
Case Summary (BLD)  7/2/2013 DONE
Letter of compliance  11/18/2003 DONE
Letter of Compliance # 24359 issued 11-14-03.
BLD-Final11/14/200311/14/200311/14/2003PPASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 11/14/2003 at 7:24:11 AM. Contact: ###-####. ok for perm occ 11/14/2003 2:06:14 PM
BLD-Final8/27/20038/28/20038/28/2003APART
DetailsDave Hannah
Scheduled by a contractor via Hello! on 8/27/2003 at 11:25:21 AM. Contact: ###-####. ok for a temp occ needs perm occ from elec and needs to finish rest rooms 8/28/2003 12:28:52 PM
Temporary occupancy  8/28/2003 DONE
Temp. Occ. Cert. #4989 issued 8-28-03 to Ahrens & Deangeli.
FIRE-Final Inspection8/26/20038/26/20038/26/2003PPASS
DetailsRick Jackson
Plan Reviewer's activity  7/18/2003 DONE
Reviewed and approved the resubmitted drawings for compliance with the "Letter of Understanding" signed by the building owners and the City of Boise.
Print Occupancy Form  7/18/2003 DONE
Plan resubmittals received  7/15/2003 DONE
Letter of Transmittal, A1.0,A3.0, A4.0, A4.1,A5.0,A5.1 and taken to Carl.
BLD-Framing/Rough-in6/19/20036/20/20036/20/2003APART
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 6/19/2003 at 3:53:01 PM. Contact: ###-####....walls & corridor barrel vault ok to cover...fireproof beams as needed (existing)....firestop elev/corridor wall penetrations as needed ( elec room ) 6/20/2003 2:30:00 PM
Issue PAID IN FULL permit  5/8/2003  
Routing - PLAN CHECK4/23/2003 4/29/2003 PASS
PLANS/APPL TAKEN TO FRONT DESK  4/29/2003 PASS
Print Occupancy Form  4/29/2003 DONE
Telephone call  4/29/2003 DONE
permit ready
Plan assigned to (CJW)3/20/2003 4/29/2003 PASS
DetailsCarl Westfall
4/29/2003 15:19:36 CJW - activity updated through activity BLDA022 from case BLD03-00539.
Routing - FIRE4/17/2003 4/22/2003 PASS
Review comments faxed to architect.
Routing - PLAN CHECK3/21/2003 4/17/2003 PASS
UBC plan review started April 16, 2003 and finished the next day. The drawings were approved with conditions. See the plan review report.
Plan resubmittals received  4/10/2003 DONE
Received three sets of resubmittal sheets A1.0, A2.0, and A3.0 with (1) Lighting Comcheck and transmittal. Routed to Carl Westfall.
Routing - PUBLIC WORKS3/20/2003 3/21/2003 PASS
Plans ACCEPTED BY PLAN TECH  3/18/2003 DONE
Plans not fully dimensioned.
Application received  3/17/2003  
Recd Pcfee & Taken To Pln CK  3/17/2003 DONE
Fee Review-notes3/17/20033/17/2003