Permit Information
Permit NumberBLD03-00776
StatusFinaled
Name BERRYHILL & COMPANY
Site Address 2170 S BROADWAY AVE
Project NameBROADWAY PARK
Customer Number 
ePlanReviewNo
Description
(BERRYHILL & COMPANY)(BROADWAY PARK) New 922 sq. ft. expansion to an existing 1,623 sq. ft. space in an existing building per approved plans on file. New total for the space will be 2,545 sq. ft. The expansion will add a dining/cafe' area with new offices and restrooms. There will be no changes to the commercial kitchen in the existing tenant space. Work to include miscellaneous interior demolition work, providing 2-hour rated fire barrier wall separations between A-2 occupancy and adjacent tenants, some new interior walls, some new interior doors and windows, interior finish, a new suspended ceiling area, new gyp. board ceiling/soffit area, a new accessible restroom, mechanical work, plumbing work, and electrical work. An alternate approval letter is attached to the plans allowing only a one-hour fire barrier wall at the tenant's existing kitchen, where no work is occurring, and where common to the adjacent tenant. An additional exit is also provided as part of the alternate approval from the A-2 occupancy for a total of three. If a new restaurant tenant moves into the space in the future, the kitchen common wall to the adjacent tenant will be required to be upgraded to a 2-hour rating. Separated uses per IBC Section 302.3.3. A new Certificate of Occupancy is to be issued when completed and approved. NOTE: This building is NOT fire sprinklered. (PC#0192-03) JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  12/10/2014 DONE
Fee Review-notes8/20/20038/20/20038/20/2003 DONE
First Notice 7/31/20037/31/2003 DONE
Permanent occupancy  7/31/2003 DONE
Perm. Occ. Cert. #9747 issued 7-31-03 to Berryhill & Company.
BLD-Aging Inspection7/29/20037/29/20037/29/2003 PASS
DetailsJim Storey
final ok 7/29/2003 8:04:36 AM
Permanent Occupancy 5/28/20035/28/2003 DONE
Details
BLD-Final5/27/20035/28/20035/28/2003APASS
DetailsJim Storey
Scheduled by a contractor via Hello! on 5/27/2003 at 4:10:13 PM. Contact: ###-####. final ok sign offs archived. 5/28/2003 10:19:30 AM
Temporary occupancy  5/28/2003 DONE
Temp. Occ. Cert. #4956 issued 5-28-03 to Berryhill & Company in Broadway Park complex.
FIRE-Final Inspection5/23/20035/27/20035/27/2003APASS
DetailsTroy Cobbley
Fire life safety is OK. Door hardware was not installed yet but what the contractor showed me in the boxes would be OK 5/27/2003 9:47:18 AM
BLD-Final5/23/20035/27/20035/27/2003PFAIL
DetailsJim Storey
shannon; Phone #: ###-#### Internet Inspection Request from: Darla Downs NEED PLM/ HEALTH DEPT./ PANIC HARDWARE ON BACK DOOR. 5/27/2003 2:45:31 PM
FIRE-Final Inspection5/23/20035/23/20035/23/2003PNR
DetailsRick Jackson
shannon; Phone #: ###-#### Internet Inspection Request from: Barbara Moore met with the GC as they weren't ready for a final; exit signs need to be tested; exit doors to the east and west to be openable from the inside without special knowledge; hang extinguisher at east exit; kitchen area was exsisting and now work was performed in this area; will need to mount the K class extinguisher 5/23/2003 3:14:01 PM
BLD-Framing/Rough-in5/14/20035/15/20035/15/2003AFAIL
DetailsJim Storey
###-#### ###-#### need fuseable link at fire damper/ need min 44 inch width for hallway. 5/15/2003 4:02:24 PM
Plan assigned to (JCB)4/17/2003 5/14/2003 PASS
DetailsJason Blais
5/14/2003 10:27:27 JCB - activity updated through activity BLDA022 from case BLD03-00776.
Routing - PLAN CHECK5/14/2003 5/14/2003 PASS
Permit and plans approved and taken to front desk.
PLANS/APPL TAKEN TO FRONT DESK  5/14/2003 PASS
Inspection Record Card- Bld  5/14/2003  
Print Occupancy Form  5/14/2003  
Override - Parcel Holds  5/14/2003  
Issue PAID IN FULL permit  5/14/2003 DONE
Routing - PLAN CHECK4/24/2003 5/13/2003 PEND
Plan review sent to architect. No response required. Plans to route to Fire Dept. for review. When approved by Fire Dept. permit can be issued.
Routing - FIRE5/13/2003 5/13/2003 PASS
Comments faxed to architect.
Telephone call  5/12/2003  
Called architect to let him know an alternate approval would be accepted by the Building Director for the existing kitchen/adjacent tenant common wall where no work is occurring as only one hour rated, but the new A-2 expansion area must have a 2-hour fire barrier wall separation where common to adjacent tenants. The alternate approval also includes an additional exit from the A-2 for a total of three exits. Any new restaurant tenant that would occupy the space in the future would be required to upgrade the kitchen common wall to the adjacent tenant to a 2-hour rating.
Plan resubmittals received  5/8/2003  
Plan resubmittals provided.
Telephone call  5/8/2003  
Called architect concerning new code requirement of 2-hour fire barrier walls. Architect indicated an alternate approval request would be provided.
Telephone call  5/7/2003  
Called architect concerning some code issues needing to be addressed.
Routing - PLUMBING4/22/2003 4/24/2003 PASS
1. water heater may need pan w/drain to approved location 2. may need thermal expansion protection
Routing - PUBLIC WORKS4/17/2003 4/22/2003 PASS
Routing Off Site - C.D.H4/15/2003 4/16/2003 PASS
Contacted Cory Nelson at ###-#### to take plans out to CDH for review. kmm\\ approved by CDH Bob Mayer
Plans ACCEPTED BY PLAN TECH  4/16/2003 DONE
Plans ACCEPTED BY PLAN TECH  4/14/2003 FAIL
no CDH signature have call into Bob Mayer
Telephone call  4/11/2003 DONE
Contacted Bob Mayer at ###-####, left message for him to give us a call regarding signature for this project. kmm
Application received  4/11/2003  
Recd Pcfee & Taken To Pln CK  4/11/2003 DONE
Fee Review-notes4/11/20034/11/2003   
we need fire values included in the total value. they are noted as n/a