Permit Information
Permit NumberBLD03-01063
StatusFinaled
Name BRASSEY, WETHERELL, CRAWFORD & MCCURDY LLP
Site Address 203 W MAIN ST
Project NameLAW OFFICE
Customer Number 
ePlanReviewNo
Description
(BRASSEY, WETHERELL, CRAWFORD & McCURDY, L.L.P.) This building is not fire sprinklered. To construct a 1,681 square foot 2 story addition to an existing 6,111 square foot historic building. After the addition, this building will have a 1,072 square foot basement, a 2,810 square foot 1st floor, a 2,710 square foot 2nd floor, and a 1,200 square foot 3rd floor (with a loft). The new addition will have a concrete footing and foundation system, insulated wood floor over a crawl space, wood stud walls with wood structural sheathing, and an engineered wood truss roof with wood structural decking. Two restrooms accessible to the disabled will be constructed on the 1st floor in the original portion of the building. A route accessible to the disabled will be provided to the 1st floor. The historic elements within the historic portion of this building are regulated by the 1994 Uniform Code for Building Conservation (UCBC). All new work shall comply with all applicable codes and ordinances. DRH03-00051 **CJW**
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Code Occupancy Approval1/8/20041/8/20041/8/2004PPASS
DetailsWm. Michael Meloy
Compliance met. 1/8/2004 1:38:00 PM
First Notice 1/8/20041/8/2004 DONE
PubWorks Occupancy Approval1/8/20041/8/20041/8/2004 DONE
Drainage project complete, OK to sign permanent occupancy to C.Weisshaupt 1/8/04. D.Erskine
Permanent Occupancy 1/8/20041/8/2004 DONE
Details
Permanent occupancy  1/8/2004 DONE
Perm. Occ. Cert. # 9924 issued 1-8-04 to Brassey, Wetherell, Crawford & MCCurdy, LLP.
BLD-Final12/30/200312/31/200312/31/2003APASS
DetailsDave Hannah
Scheduled by a contractor via Hello! on 12/30/2003 at 1:33:50 PM. Contact: ###-####. 12/31/2003 10:11:13 AM ok for perm occ 12/31/2003 10:12:07 AM
Print Occupancy Form  12/31/2003 DONE
Inspection Record Card- Bld  12/31/2003 DONE
FIRE-Final Inspection11/25/200311/26/200311/26/2003APASS
DetailsRick Jackson
Scheduled by a contractor via Hello! on 11/25/2003 at 9:53:02 PM. Contact: ###-####.
BLD-Final11/25/200311/26/200311/26/2003PFAIL
DetailsDave Hannah
Scheduled by a contractor via Hello! on 11/25/2003 at 9:53:41 PM. Contact: ###-####. c/n on site 11/26/2003 3:26:44 PM
FIRE-Final Inspection10/30/200310/31/200310/31/2003ANR
DetailsRick Jackson
Scheduled by a contractor via Hello! on 10/30/2003 at 5:22:13 PM. Contact: ###-####.
BLD-Final10/30/200310/31/200310/31/2003ACANC
DetailsDave Hannah
Scheduled by a contractor via Hello! on 10/30/2003 at 5:22:57 PM. Contact: ###-####.
FIRE-Final Inspection10/30/200310/31/200310/31/2003PFAIL
DetailsRick Jackson
Scheduled by a contractor via Hello! on 10/30/2003 at 11:09:49 PM. Contact: ###-####. ADA ramp door hardware not lever; exit signs on 2nd floor to be relocated per plans; is basement lid to be enclosed?; door hardware on office doors; address 10/31/2003 4:26:41 PM
BLD-Final10/30/200310/31/200310/31/2003PFAIL
DetailsDave Hannah
Scheduled by a contractor via Hello! on 10/30/2003 at 11:10:31 PM. Contact: ###-####. needs fire life safty 11/3/2003 7:54:06 AM
BLD-Final10/29/200310/30/200310/30/2003PNR
DetailsDave Hannah
Scheduled by a contractor via Hello! on 10/29/2003 at 8:08:56 PM. Contact: ###-####.needs other trades fanaled 10/30/2003 3:27:13 PM
FIRE-Final Inspection10/29/200310/30/200310/30/2003PNR
DetailsTroy Cobbley
Inspection was actually a conference. I went over the life safety notes with the contractor. Specifically the placement of fire extinguishers. 10/30/2003 2:37:57 PM
BLD-Framing/Rough-in8/13/20038/14/20038/14/2003PPART
DetailsDave Hannah
Scheduled by a contractor via Hello! on 8/13/2003 at 7:54:01 PM. Contact: ###-####. shear ok to cover ext and int shear walls also ok to start covering int walls new office area first and sec floors foem seal is done contractor will cieling off on second floor hallway so mec can be checked after units are set 8/14/2003 4:02:10 PM
BLD-Framing/Rough-in8/12/20038/13/20038/13/2003ANR
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 8/12/2003 at 4:02:41 PM. Contact: ###-####.
BLD-Framing/Rough-in8/13/20038/13/20038/13/2003PFAIL
DetailsCarl Dependahl
need plans... 8/13/2003 3:04:34 PM
BLD-Framing/Rough-in8/13/20038/13/20038/13/2003PFAIL
DetailsCarl Dependahl
complete air seal, provide plans 8/13/2003 3:01:06 PM
BLD-Framing/Rough-in8/10/20038/11/20038/11/2003PCANC
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 8/10/2003 at 9:02:37 PM. Contact: ###-####.
BLD-Framing/Rough-in8/7/20038/8/20038/8/2003AFAIL
DetailsCarl Dependahl
Scheduled by a contractor via Hello! on 8/7/2003 at 7:14:15 PM. Contact: ###-####....nail shear panels & sills per plan, obtain hvac ok; no further insp. 8/8/2003 11:51:16 AM
BLD-Foundation7/10/20037/11/20037/11/2003APART
DetailsCarl Dependahl
jeremy stem wall; Phone #: ###-#### Internet Inspection Request from: Barbara Moore...pending strata's reports 7/11/2003 1:27:25 PM
BLD-Footing7/7/20037/8/20037/8/2003PFAIL
DetailsJim Storey
Scheduled by a contractor via Hello! on 7/7/2003 at 2:08:21 PM. Contact: ###-####.need compaction report from stradia special insp. for fill and rebar clearance from bottom of footing. ground in place. 7/8/2003 2:10:45 PM
Issue PAID IN FULL permit  7/2/2003 DONE
Routing - PLAN CHECK6/25/2003 6/25/2003 PASS
PLANS/APPL TAKEN TO FRONT DESK  6/25/2003 PASS
Print Occupancy Form  6/25/2003 DONE
Telephone call  6/25/2003 DONE
permit ready and need ACHD
Plan assigned to (CJW)5/14/2003 6/25/2003 PASS
DetailsCarl Westfall
6/25/2003 08:46:09 CJW - activity updated through activity BLDA022 from case BLD03-01063.
Routing - FIRE6/23/2003 6/24/2003 PASS
Resubmittal acceptable.
Routing - PLAN CHECK6/18/2003 6/23/2003  
Plan resubmittals received  6/23/2003 DONE
Memo letter form T.J. Scofield & Associates, letter from United Water, 2 Calculation plans, taken to Carl W.
Routing - FIRE6/13/2003 6/17/2003  
Failed first IFC review. Hydrant and available water flow info required.
Routing - PLAN CHECK5/29/2003 6/13/2003 PASS
UBC plan review started June 9, 2003 and finished June 13, 2003. The drawings were approved with conditions. See the conditions list.
Routing - PLUMBING5/27/2003 5/28/2003 PASS
1. existing water heater needs T&P with drain 2. verify floor drain for T&P drains in basement 3. L-2 lavs need vents
Routing - PLANNING5/21/2003 5/23/2003 PASS
Approved per DRH03-51.
Routing - PUBLIC WORKS5/14/2003 5/16/2003 PASS
Brian, Gene stated on 5/12/03 that he had talked with you earlier and that you had told him nothing was needed. kmm
Routing - Erosion and Sediment5/16/2003 5/16/2003 PASS
ESC approved with conditions attached to plans.
Routing - PLANNING Land Div5/12/2003 5/14/2003 PASS
Pending Assignment by DJO5/12/2003 5/14/2003 DONE
DetailsDan Overy
5/14/2003 11:40:23 KMM - activity updated through activity BLDA172 from case BLD03-01063.
Plan routing begun/NEW & ADDTN  5/12/2003 DONE
Plans ACCEPTED BY PLAN TECH  5/12/2003 DONE
Had Gene Kelly talk with Brian M. On 5/12/03 Gene stated he had talked with Brian earlier and that Brian did not require any civil. kmm
Override - Parcel Holds  5/8/2003  
Application received  5/8/2003  
Override - Parcel Holds  5/8/2003  
Recd Pcfee & Taken To Pln CK  5/8/2003 DONE
Fee Review-notes5/8/20035/8/2003