Permit Information
Permit NumberBLD03-01116
StatusFinaled
Name PAD THAI HOUSE RESTAURANT
Site Address 1473 S FIVE MILE RD
Project NameELMS PARK CENTER
Customer Number 
ePlanReviewNo
Description
(PAD THAI HOUSE RESTAURANT)(ELMS PARK CENTER) To remodel and expand a previous 1,440 sq.ft. food service tenant space to a 2,876 sq.ft. full service restaurant per approved plans on file. Work includes selective interior demolition of non-bearing walls to create openings between the two spaces & enlarge seating areas; to construct interior walls to create a storage area; to install a new Type I grease hood system with Firemaster duct wrap ER- for fire shaft protection; installation of Type II hood system over dishwasher; upgrade of electrical, mechanical, plumbing and fire sprinkler system to meet the tenants needs and comply with current adopted cods & ordinances. All per approved plans and attached plan review comments / conditions & reports. NOTE: This building is fully sprinklered for allowable area increase. PC03-278/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/27/20043/1/20043/1/2004APASS
DetailsRuss Owen
Jenny; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes. Ok perm oc. 2/29/2004 6:08:55 PM
First Notice 3/1/20043/1/2004 DONE
Permanent Occupancy 3/1/20043/1/2004 DONE
Details
Permanent occupancy  3/1/2004 DONE
Perm. Occ. Cert. # 10011 issued 3-1-04 to the Pad Thai House Restaurant.
BLD-Wall cover2/13/20042/17/20042/17/2004ACANC
DetailsRuss Owen
Jenny; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
BLD-Final2/16/20042/17/20042/17/2004APART
DetailsRuss Owen
All ok now except rear doors, hardware needs to be openable w-out thumb turn. talked with owner he will change out and recall. 2/16/2004 6:35:34 PM
FIRE-Final Inspection2/11/20042/11/20042/11/2004APASS
DetailsTroy Cobbley
Fire life safety, fire sprinkler and fire alarm finaled
FIRE-Conference12/16/200312/17/200312/17/2003ADONE
DetailsTroy Cobbley
jenny ###-#### Had conference with Jenny and went over remaining items before I can sign a permanent occupancy 12/17/2003 1:59:52 PM
FIRE-Final Inspection12/15/200312/16/200312/16/2003PCANC
DetailsTroy Cobbley
I stopped by the job site and spoke with the male owner. I told him that I could not do a fire life safety inspection since the fire alarm plans had not been approved yet. He agreed and I left the project. Jenny called me later and asked if I could reschedule for tomorrow and do a life safety conference. I scheduled it for tomorrow. 12/16/2003 2:35:08 PM
BLD-Final9/19/20039/22/20039/22/2003APART
DetailsRuss Owen
Jenny, ###-#### .needs health dept and fire/life safety. also c/n posted clearances door hdware. Ok for a temp oc only. 9/21/2003 7:15:14 PM
Temporary occupancy  9/22/2003 DONE
Tremp. Occ. Cert. #5000 issued 9-22-03 to the Pad Thai House Restaurant.
FIRE-Final Inspection9/18/20039/19/20039/19/2003APART
DetailsTroy Cobbley
temporary occupancy given with dave millers permission until the fire alarm plans are complete and finaled 9/19/2003 9:59:49 AM
FIRE-Final Inspection9/18/20039/19/20039/19/2003PCANC
DetailsTroy Cobbley
duplicate inspection. Project was given a temp in the morning. 9/19/2003 4:19:46 PM
FIRE-Final Inspection9/5/20039/8/20039/8/2003AFAIL
DetailsRick Jackson
JENNY; Phone #: ###-#### Internet Inspection Request from: Marc Lileks Need fire sprinkler plans; sprinkler head needed in walk-in cooler; sprinkler head too close to wall by beverage area and overspaced from north wall; need 401 canopies on all sprinkler heads; post maximum load 79 sign at main exit; provide emergency lighthing as shown on plans; provide air balance report; install "Door to remain unlocked..." sign at main exit; doors A and E to be openable from the inside without special knowledge - plans show panic hardware; submit alarm plans for new hood extinguishing system 9/8/2003 10:17:18 AM
BLD-Framing/Rough-in7/31/20038/1/20038/1/2003APART
DetailsRuss Owen
###-#### jenny; Phone #: ###-#### Internet Inspection Request from: Barbara Mooreok except need braces at top of new walls posted c/n. 8/1/2003 12:40:49 PM
BLD-Conference7/22/20037/23/20037/23/2003ACANC
DetailsRuss Owen
air; Phone #: ###-#### Internet Inspection Request from: Annette Moore Was done day before ? also this number is for a place in oregon.7/23/2003 1:44:42 PM 7/23/2003 1:45:04 PM
BLD-Conference7/21/20037/22/20037/22/2003PDONE
DetailsSteven Webb
AUTOM..SHE WILL CALL YOU TO SCHEDULE A TIME; Phone #: ###-#### Internet Inspection Request from: Dixie Fellows
Issue & PRINT permit  7/17/2003 DONE
Plan assigned to (DRS)5/20/2003 7/16/2003 PASS
DetailsDan Stuart
7/16/2003 08:18:00 DRS - activity updated through activity BLDA022 from case BLD03-01116.
PLANS/APPL TAKEN TO FRONT DESK  7/16/2003 PASS
To permit desk for processing to issue permits.
Inspection Record Card- Bld  7/16/2003 DONE
Print Occupancy Form  7/16/2003 DONE
Telephone call  7/16/2003 DONE
left mess that permit is ready
Routing - PLAN CHECK6/25/2003 7/15/2003 PASS
New resubmittal sheets one & two provided with clarification cover letter. Talked with architect and business owner Jenny Boutkaska concerning providing compliance within the kitchen per section 804 ICC/ANSI. Noted same on plans and in plan review comments.
Telephone call  7/15/2003 DONE
Call from Jenny Boutkaska, tenant, concerning plan review. Told her I was wraping up the inserting of the resubmittals and making notes on the plans concerning need to comply with the IBC & ICC for accessibility within the kitchen per section 1108 IBC & 804 ICC. Architect had provided call out notes but no elevations. The notes on the plans & the code section noted will need to be complied with and verification will be in the field by the appropriate inspector. Failure to comply may cause delays in opening. I suggested she have the architect verify anything she has a question on before installing.
Telephone call  7/15/2003 DONE
Called architect, Larry Sundell, to discuss the accessibility isssues within the kitchen per section 804 ICC & 1108 IBC. He had noted all cabinets were a standard 36" in height. I indicated section 804 of ICC required work surfaces to be from 28" min to 34" max above the floor and requirements for appliances, storage, maneuverability, floor clearances, etc. covered in 804 that would need to be met. I explained I was making the section reference and notes in plan review comments & on the plans for requirements and stating that anyone having concerns oor questions concerning these items was to contact him for direction prior to installing the item.
Plan Reviewer's activity  7/15/2003 DONE
Discussed section 1108 on kitchen accessibility and 804 ICC/ANSI for kitchens with staff members & Marlene Southard, plan check manager, on procedure for use of this code section. I was told to make the note of the code sections stating requirements on the plans & in plan review comments to bring it to the attention of contractors and tenant and to notify the tenant and architect that these items would need to be addressed in the field & approved by the inspector. I have followed this process and am taking the plans to tht permit desk to issue.
Plan resubmittals received  7/3/2003 DONE
Received two copies of revised sheets one of two and two of two. One copy of response letter and freezer price list and information. Routed to Dan S. kmm
Routing - FIRE6/23/2003 6/25/2003 PASS
Routing - PLAN CHECK5/29/2003 6/23/2003 FAIL
Plan resubmittals required. Routing to fire code analyst. Plan check comments mailed to architect. Phone number and fax are same for architect and his machine did not kick over to receive fax, only told me he was not in and to leave a message.
Plan resubmittals requested  6/23/2003 FAIL
Copy of plan check report to architect for resposne and clarifications.
Routing - PLUMBING5/28/2003 5/29/2003 PASS
1. existing water heater may require thermal expansion and a pan with a drain 2. may require building backflow protection 3. ice machine, soda and coffee machines may require additional backflow protection 4. plans do not show location of p-10. need a p-10 at food prep sink and 3 compartment sink
Routing - PUBLIC WORKS5/20/2003 5/28/2003 PASS
DetailsBrandi Dominguez
Routing Off Site -Energy5/20/2003 5/21/2003 PASS
Contacted Ron O for energy review. kmm
5/21/03 - Report from Ron Oltman declaring Building Envelope & lighting as not requiring any upgrades oe changes and that a damper be provided at the grease hood exhaust fan, that will close automatically when the exhaust sytem is off. Copy of report attached to plans.
Plans ACCEPTED BY PLAN TECH  5/15/2003 DONE
Application received  5/15/2003  
Recd Pcfee & Taken To Pln CK  5/15/2003 DONE
Fee Review-notes5/15/20035/15/2003