Permit Information
Permit NumberBLD03-01356
StatusFinaled
Name HEINZ DEVELOPMENT
Site Address 1744 N MITCHELL STREET
Project NameExeter Center
Customer Number 
ePlanReviewNo
Description
(Bruce Dental Clinic)(Exeter Center Building C) * To construct a 3,467 sq. ft., two story, Type VB dental clinic. Other work inlcudes all site improvements, paving and landscaping per approved plans and attachments, DRH00-00183 CUP00-00028 CVA00-00005 3012 sq. ft. first floor and 455 sq. ft. second floor.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  7/28/2008  
BLD-Final4/6/20044/7/20044/7/2004APASS
DetailsTom Arcoraci
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok for perm occ 4/7/2004 8:30:53 AM
First Notice 4/7/20044/7/2004 DONE
Permanent Occupancy 4/7/20044/7/2004 DONE
Details
Permanent occupancy  4/7/2004 DONE
Perm. Occ. Cert. # 10083 issued 4-7-04 to the Bruce Dental Clinic.
BLD-Final3/23/20043/24/20043/24/2004ANR
DetailsJim Sly
tom heinz-- -###-####
BLD-Final3/24/20043/24/20043/24/2004PPART
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/24/2004 at 9:33:47 AM. Contact: ###-####. Temp Occ. OK Pending Plumb and Med gas approval. 3/24/2004 2:35:29 PM
FIRE-Final Inspection3/23/20043/23/20043/23/2004PPASS
DetailsTroy Cobbley
fire life safety finaled
PubWorks Occupancy Approval3/22/20043/22/20043/22/2004 DONE
Drainage found complete, letter from owner verified drainage, approved by Brian Murphy 3/22/04.
BLD-Conference3/19/20043/19/20043/19/2004PPASS
DetailsJim Sly
Scheduled by a contractor via Hello! on 3/19/2004 at 9:44:09 AM. Contact: ###-####.
FIRE-Final Inspection3/17/20043/18/20043/18/2004AFAIL
DetailsTroy Cobbley
Provide fire sprinkler protection in the gas closet per the review notes. Provide verification that the exhaust tubes on the duct smoke detectors can have inlet holes as the installation instructions do not shown this 3/18/2004 10:34:13 AM
BLD-Framing/Rough-in3/9/20043/9/20043/9/2004PPASS
DetailsJim Sly
ceiling grid inspection please///mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
BLD-Framing/Rough-in12/23/200312/24/200312/24/2003APASS
DetailsJim Sly
mike; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD-Framing/Rough-in12/18/200312/19/200312/19/2003APART
DetailsTom Arcoraci
Mike; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes ok to insulate need 1 hr to deck on south and east wall see plan 12/19/2003 9:31:29 AM
BLD-Framing/Rough-in11/12/200311/12/200311/12/2003PPASS
DetailsJim Sly
shear wall inspection please//mike heinz; Phone #: ###-#### Internet Inspection Request from: Barbara Moore OK to cover E and S walls. 11/12/2003 4:08:19 PM
BLD-Foundation10/10/200310/10/200310/10/2003PPART
DetailsRuss Owen
STEVE; Phone #: ###-#### Internet Inspection Request from: Darla Downs Ok pending letter from engineer will get asap. 10/9/2003 10:56:37 PM
BLD-Footing10/8/200310/9/200310/9/2003APART
DetailsJim Sly
LAZARO; Phone #: ###-#### Internet Inspection Request from: Darla Downs Footing and Bar OK.....Need letter from Eng 4000/3500 PSI... to 2500 PSI. 10/9/2003 12:06:58 PM
(F) Reprint permit  9/30/2003  
Inspection Record Card- Bld  9/29/2003 DONE
Issue PAID IN FULL permit  9/29/2003 DONE
PLANS/APPL TAKEN TO FRONT DESK  9/11/2003 DONE
Inspection Record Card- Bld  9/11/2003 DONE
Print Occupancy Form  9/11/2003 DONE
Permit Ready to Issue  9/11/2003 DONE
Telephone call  9/11/2003 DONE
Left message permit ready and fees due
Plan assigned to (MLO)6/11/2003 9/11/2003 PASS
DetailsMike Otto
9/11/2003 10:21:57 MLO - activity updated through activity BLDA022 from case BLD03-01356.
Routing - PLUMBING9/8/2003 9/10/2003 PASS
SEPARATE MED AIR INTAKE FROM VACUUM EXHAUST AT ROOF LINE TO EXCLUDE CROSS CONTAMINATION, PER RESUBMITTED PLANS AND LETTER DATED 9/8/03
Plan resubmittals received  9/8/2003 DONE
Received three copies of revised sheets P1.1, P3.0, P4.0, one copy of cover letter. Routed to Mike O. kmm
Routing - PUBLIC WORKS8/28/2003 9/3/2003 PASS
Routing - PLUMBING8/27/2003 8/27/2003 FAIL
prime f.d. s and f.s. s, rp required on service installed over floor sink, the med air compressor area shall be located separately from med gas cylinder system sources and be provided with drainage facilities, med vacuum plant shall have drainage facilities, show locations of med air and vacuum intake and exhaust.
Plan resubmittals requested  8/15/2003 DONE
energy corrections
Routing Off Site -Energy8/15/2003 8/15/2003 PASS
Corrections have been satisfied approval has been emailed. MLO
Routing Off Site -Energy8/8/2003 8/15/2003 FAIL
Contacte Ron O for energy review. kmm Corrections sent to architect MLO
Routing - PUBLIC WORKS8/8/2003 8/14/2003 FAIL
Requires Drainage plan Revision per Brian M. kmm
Routing - PLANNING8/7/2003 8/8/2003 PASS
Approved per DRH03-141.
Routing - PLAN CHECK8/5/2003 8/7/2003 PASS
Routing - FIRE7/30/2003 8/4/2003 PASS
jResubmittal acceptable
Plan resubmittals received  8/4/2003 DONE
Response letter, three copies of A-2.0, two copies of A-3.0,A-4.0,A-6.1, A-7.0, A-9.0 taken to Mike O.
Routing - PLAN CHECK7/28/2003 7/30/2003 FAIL
corrections sent to architect
Plan resubmittals requested  7/30/2003 DONE
IBC and energy
Plan resubmittals received  7/28/2003 DONE
received response letter, response letter to Sam Rogers, two sets of A-0.0,A-1.0,A-2.0,A-3.0,A-4.0,A-5.1,A-6.0,A-6.1,A-7.0,A-8.0,A-9.0,P4.0, P5.0, taken to Mike O.
Routing - FIRE7/15/2003 7/21/2003 FAIL
inadequate hydrant and flow information; review comments faxed to architect.
Routing Off Site -Energy6/11/2003 7/15/2003 FAIL
Contacted Ron Oltman for energy review. kmm Corrections sent to architect
Routing - PLAN CHECK7/2/2003 7/15/2003 FAIL
corrections sent to architect
Routing - PLUMBING6/27/2003 7/1/2003 FAIL
water heater requires a pan with drain, provide a med gas plan that complies with the min. requirements of the 2000 upc or nfpa 99c.
Routing - PLANNING6/20/2003 6/27/2003 FAIL
Design Review application required for proposed office building.
Routing - Erosion and Sediment6/19/2003 6/20/2003 PASS
ESC approved with conditions attached to plans.
Routing - PUBLIC WORKS6/13/2003 6/19/2003 FAIL
Requires drainage plan revisions. Per Brian M. kmm
Routing - PLANNING Land Div6/11/2003 6/12/2003 PASS
Approved. Lot 3 of Block1 of Exeter Subdivision.
Plans ACCEPTED BY PLAN TECH  6/11/2003 DONE
Plan routing begun/NEW & ADDTN  6/11/2003 DONE
Application received  6/10/2003  
Recd Pcfee & Taken To Pln CK  6/10/2003 DONE
Fee Review-notes6/10/20036/10/2003