Permit Information
Permit NumberBLD03-01695
StatusFinaled
Name GERALD TEAL
Site Address 6126 W STATE ST
Project NamePierce Park Sub
Customer Number 
ePlanReviewNo
Description
Sel Equity Real Estate Office Building * To construct a new 7,830 square foot, two story, wood framed office building on the east side of an existing two story office building. The new building first floor 4760 square feet, second floor 3070 square feet, total 7830 square feet. This new building will be fully fire sprinklered. The new building will be separated from the existing building by a two-hour fire resistive fire wall. All construction per the approved plans and attached comment list. Per the structural engineer, this site class "D" and seismic design category "C". DRH03-00022/PC#403-03/JCM
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD4/26/20054/26/20054/26/2005 DONE
First Notice has not been responded to.
First Notice 6/17/20044/26/2005 DONE
Permanent occupancy  6/17/2004 DONE
Perm. Occ. Cert. # 10190 issued 6-17-04 to Sel Equity Real Estate.
BLD-Final6/4/20046/4/20046/4/2004PPASS
DetailsTony Young
Scheduled by a contractor via Hello! on 6/4/2004 at 7:36:42 AM. Contact: ###-####.
ok for perm c of o 6/4/2004 4:27:42 PM
Permanent Occupancy 6/4/20046/4/2004 DONE
Details
BLD-Final4/26/20044/26/20044/26/2004APART
DetailsTony Young
Scheduled by a contractor via Hello! on 4/26/2004 at 7:26:39 AM. Contact: ###-####.
temp. occ. ok,,, need to finish a d a items,,, trades 4/26/2004 2:01:44 PM
Temporary occupancy  4/26/2004 DONE
Temp. Occ. Cert. # 5103 issued 4-26-04 to the Sel Equity Real Estate Office Bldg.
BLD-Final4/22/20044/23/20044/23/2004PNR
DetailsTony Young
john; Phone #: ###-#### Internet Inspection Request from: Annette Moore
conf. only on handrails, A.D.A. issues 4/23/2004 3:13:45 PM
BLD-Final4/14/20044/15/20044/15/2004ANR
DetailsTony Young
John; phone# ###-####
BLD-Conference4/13/20044/14/20044/14/2004ACANC
DetailsTony Young
conference on on final w/ John ###-####
BLD-Final4/14/20044/14/20044/14/2004PCANC
DetailsTony Young
john;phone#8674584
FIRE-Final Inspection4/13/20044/13/20044/13/2004APASS
DetailsTroy Cobbley
fire life safety finaled 4/13/2004 8:23:40 AM
BLD-Conference4/13/20044/13/20044/13/2004PNR
DetailsTony Young
Scheduled by a contractor via Hello! on 4/13/2004 at 7:17:04 AM. Contact: ###-####.
FIRE-Final Inspection4/12/20044/12/20044/12/2004AFAIL
DetailsTroy Cobbley
Provide approved door hardware on the second floor double doors at conference room
PubWorks Occupancy Approval4/10/20044/10/20044/10/2004 DONE
Drainage project complete, signed permanent occupancy 4/10/04. R.Rokovitz
FIRE-Final Inspection4/8/20044/8/20044/8/2004PFAIL
DetailsTroy Cobbley
Need to address issues for the fire alarm and the fire sprinkler inspections which include alarm signals being incorrect and no updated fire sprinkler drawings on site for their inspection. Other issues include exit signs and emergency lights not working, white lettering on the fire dept. access lanes, signage on riser room, hydraulic placards for riser, NFPA 25, forward flush of the backflow preventer. 4/8/2004 4:24:43 PM
BLD-Wall cover2/11/20042/12/20042/12/2004APASS
DetailsTony Young
Scheduled by a contractor via Hello! on 2/11/2004 at 11:43:17 AM. Contact: ###-####.
ok to cover all 2/13/2004 5:24:35 PM
FIRE-Conference2/3/20042/3/20042/3/2004APART
DetailsTroy Cobbley
sprinkler piping on the north and south sides of the 2nd floor beams is ok to cover 2/3/2004 10:20:53 AM
BLD-Wall cover2/3/20042/3/20042/3/2004APART
DetailsTony Young
Scheduled by a contractor via Hello! on 2/3/2004 at 6:40:52 AM. Contact: ###-####.
ok to cover rake areas on front and rear,, also the soffit areas 2/3/2004 10:23:14 AM
BLD-Conference1/29/20041/30/20041/30/2004APART
DetailsTony Young
ph ###-####, Tony, re-inspect upper area between beams, b-4 10am
ok to cover ceiling between beams on upper floor 1/30/2004 10:32:45 AM
FIRE-Conference1/28/20041/29/20041/29/2004ADONE
DetailsTroy Cobbley
Inspection was for sprinkler rough-in 1/29/2004 10:46:55 AM
BLD-Wall cover1/28/20041/29/20041/29/2004AFAIL
DetailsTony Young
Scheduled by a contractor via Hello! on 1/28/2004 at 8:45:18 PM. Contact: ###-####.
need to brace trusses, secure blocking, block under roof joists/plate 1/29/2004 2:55:55 PM
BLD-Framing/Rough-in1/12/20041/12/20041/12/2004PPART
DetailsTony Young
john center building shear; Phone #: ###-#### Internet Inspection Request from: Darla Downs
ext shear on connecter building ok 1/12/2004 3:16:50 PM
BLD-Framing/Rough-in12/22/200312/22/200312/22/2003PPART
DetailsTony Young
Tony -- sheer; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
exterior shear ok 12/22/2003 4:35:19 PM
BLD-Framing/Rough-in12/18/200312/18/200312/18/2003PFAIL
DetailsTony Young
John --- sheer; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
need to nail #2 walls better, finish straps and bolting 12/18/2003 4:24:31 PM
BLD-Conference12/17/200312/17/200312/17/2003PCANC
DetailsTony Young
john ###-####
BLD-Conference11/20/200311/21/200311/21/2003APART
DetailsTony Young
john; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
bolts in colums ok, do draft stops per plan, truss bearing will be ok near steel colums due to added ftg 11/21/2003 11:39:49 AM
BLD-Foundation10/23/200310/23/200310/23/2003PPART
DetailsTony Young
John; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
BLD-Footing10/21/200310/22/200310/22/2003APART
DetailsTony Young
John; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
BLD-Footing10/20/200310/21/200310/21/2003PCANC
DetailsTony Young
Scheduled by a contractor via Hello! on 10/20/2003 at 3:30:15 PM. Contact: ###-####. cancel per John
Issue PAID IN FULL permit  10/16/2003 DONE
Permit Ready to Issue  10/14/2003  
Telephone call  10/14/2003 DONE
left mess that permit is ready
Plan assigned to (JCM)7/15/2003 10/13/2003 PASS
DetailsJohn Menard
10/13/2003 16:28:47 JCM - activity updated through activity BLDA022 from case BLD03-01695.
Routing - FIRE10/9/2003 10/13/2003 PASS
resubmittal acceptable with delayed water supply upgrade agreement approved by the FD.
Routing - PLANNING10/13/2003 10/13/2003 PASS
Approved per DRH03-22 and as noted on sheet A1-1.
Routing - PLAN CHECK10/13/2003 10/13/2003 PASS
PLANS/APPL TAKEN TO FRONT DESK  10/13/2003 PASS
Inspection Record Card- Bld  10/13/2003  
Print Occupancy Form  10/13/2003  
Routing - PLAN CHECK9/30/2003 10/9/2003  
Plan resubmittals received  10/9/2003 DONE
Received letter to Dave Miller regarding United Water.
Routing - FIRE9/23/2003 9/30/2003 FAIL
Resubmittal exceptable except inadequate hydrant flow available, unless building is fully sprinklered or hyd flow is increased. Architect to discuss with Dave Miller.
Routing Off Site -Energy9/19/2003 9/24/2003 PASS
sent to Ron O. Received an e-mail from Ron O. approving resubmittals. JCM
Routing - PLAN CHECK8/21/2003 9/23/2003 FAIL
Plan resubmittals received  9/23/2003 DONE
Received a reference letter with three E-4 sheets. Taken to John
Plan resubmittals requested  9/22/2003  
Faxed the architect a request for additional resubmittals. JCM
Plan resubmittals received  9/18/2003 DONE
Received comments for plan review, letter to Sam Rogers, letter from United Water, reference letter to John about outside energy, 8 copies of zone design cooling load summary F-1,F-2,F-3,F-4,F-5,F-6,F-7,F-8., two copies of Electrical Submittal from Rocky Mountain Electric, two sets of A0-1A1-2,A2-0, A2-1, A2-2, A2-3, A2-4, A2-5, A2-6, A2-7, A2-8, A2-9, A2-10, A2-11, A3-3, A4-2, A4-5, A4-6, A4-7, A4-8, A4-9, A7-2, A7-3, M-1, M-2, P-1, P-2, E-1, E-2, E-3. taken to John M.
Plan resubmittals received  9/18/2003 DONE
Received transmittal letter with one set of sheets A3-.,A4-9,E-1, E-2, E-3 taken to John M.
Routing - FIRE8/14/2003 8/20/2003 FAIL
FD access, fire hydrant flow and hydrant issues to be addressed. Copy of review faxed to architect.
Plan resubmittals requested  8/20/2003  
Faxed the architect a copy of the energy review requesting revisions. JCM
Routing Off Site - STRUCTURAL8/14/2003 8/19/2003 PASS
Contacted PDQ to take response letter to outside engineering. kmm Received and e-mail from the consulting structural engineer approving the revisions. JCM
Plan resubmittals requested  8/14/2003  
Mailed the architect a copy of the plan review comment list requesting revisions. JCM
Routing - PLAN CHECK8/6/2003 8/14/2003 FAIL
Routing Off Site -Energy7/30/2003 8/14/2003 FAIL
Waiting for lighting compliance. Contacted Ron O for energy review. kmm
7/30/03 received lighting compliance sheets. Received an e-mail from Ron indicating revisions required. JCM
Routing - PLANNING Land Div8/11/2003 8/11/2003 PASS
Approved. Record of Survey #6186 recorded on 6/16/03. Notice of Buildable Parcel recorded on 7/11/03.
Routing - PLUMBING8/4/2003 8/6/2003 PASS
1. existing sewer from existing building must be sch 40 pipe and a building clean out must be installed two feet outside of the building. 2. existing building must have backflow protection and thermal expansion protection. 3. water heater must have a pan with a drain to approved location.
Plan resubmittals requested  8/5/2003  
Faxed the architect a copy of the comment list from the consulting structural engineer requesting revisions. JCM
Routing - PLANNING7/31/2003 8/4/2003 FAIL
Plans do not comply with DR conditions of approval (see DRH03-22).
Routing - Erosion and Sediment7/25/2003 7/31/2003 PASS
Put resubmittals from my desk with plans before routing to ESC. kmm
ESC approved with conditions attached to plans.
Routing Off Site - STRUCTURAL7/18/2003 7/31/2003 FAIL
Contacted PDQ to take to outside Engineering Received e-mail comment list from consulting structural engineer requesting revisions. JCM
Additional plans submitted  7/30/2003 DONE
Received three copies of sheets E-1, E-2, E-3, E-4 and light fixture drawings 81/2 x 11 size sheets. Routed to John M. and contacted Ron O for energy review. kmm
Routing - PUBLIC WORKS7/18/2003 7/25/2003 PASS
Plan resubmittals received  7/24/2003 DONE
Received one copy of soils report and two copies of ESC Plan and Narrative. Will put with plans on Monday. kmm
Plans ACCEPTED BY PLAN TECH  7/18/2003 PEND
Received 4th set of plans still witing for lighting compliance copies.
Routing - PLANNING Land Div7/18/2003 7/18/2003 FAIL
Need copy of "recorded" Notice of Buildable Parcel and "recorded" deed and new tax parcel number.
Plans ACCEPTED BY PLAN TECH  7/15/2003 PEND
needs 4th set of plans, and 4 copies of Lighting Compliance
Plan routing begun/NEW & ADDTN  7/15/2003  
Application received  7/14/2003  
Recd Pcfee & Taken To Pln CK  7/14/2003  
Fee Review-notes7/14/20037/14/2003