(OFFICE PAVILION-RACKING) To install steel storage pallet racking/shelving 16 ft. in height in existing 10,380 sq. ft. warehouse/office tenant space in existing building per approved plans on file. Work to include steel storage racking/shelving installation per requirements of IBC Chapters 16 and 22 and attached structural engineering. This is a Scope of Work Permit. Letter of Completion to be issued when done. Tenant permit was done under BLD03-00867. NOTE: This building is fully fire sprinklered for area increase. (PC#0406-03) JCB
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Second Notice BLD4/26/20054/26/20054/26/2005 DONE
First Notice has not been responded to.
First Notice 8/15/20034/26/2005 DONE
DOC - Permit Finaled8/15/20038/15/20038/15/2003APASS
DetailsRuss Owen
Finaled by inspector at 8/15/2003 11:01:56 AM
BLD-Final8/15/20038/15/20038/15/2003APASS
DetailsRuss Owen
work done 8/15/2003 11:01:46 AM
FIRE-Final Inspection8/13/20038/14/20038/14/2003PPASS
DetailsRick Jackson
tom; Phone #: ###-#### Internet Inspection Request from: Barbara Moore column protection not needed; shelves not installed as this is for pallet storage 8/14/2003 8:34:29 AM
BLD-Conference8/13/20038/13/20038/13/2003PPART
DetailsRuss Owen
add 2 bolts at south side and fire /life safety insp. 8/13/2003 5:21:30 PM
BLD-Conference8/13/20038/13/20038/13/2003PCANC
DetailsRuss Owen
phoned in 2 times. 8/13/2003 12:30:52 PM
Inspection Record Card- Bld  8/6/2003 DONE
Issue PAID IN FULL permit  8/6/2003 DONE
Routing - PLAN CHECK8/4/2003 8/5/2003 PASS
Permit and plans approved and taken to front desk.
PLANS/APPL TAKEN TO FRONT DESK  8/5/2003 PASS
Plan assigned to (JCB)7/17/2003 8/5/2003 PASS
DetailsJason Blais
8/5/2003 09:32:10 JCB - activity updated through activity BLDA022 from case BLD03-01703.
Routing - FIRE8/4/2003 8/4/2003 DONE
DetailsBill Alexander
Routing - FIRE7/30/2003 8/1/2003 FAIL
DetailsBill Alexander
Plans/submittals lack sufficient information to verify fire code requirements.
Telephone call  8/1/2003 DONE
9:20 am. Called Tom Hegge (Manager/Owner?) and requested information said he will come down and visit.
Meeting  8/1/2003 DONE
Met with Tom Hegge and went over IFC Chapter 23 minimum submittal requirements relating to his structure, type of storage use. All of which relates to commodity type information, existing fire protection system design, maximum requrested storage height, the height of floor to the roof, height of floor to bottom of trusses, top of commodity storage to fire sprinkler deflectors, type of rack shelfs invovled throughout, (how storing in the racks), whether commodity is encapsulated, banded, etc. He will fax the inforamtion to me as soon as he can.
Routing - PLAN CHECK7/17/2003 7/30/2003 PEND
Plan review report faxed to applicant. No response required. When approved by Fire Dept. permit can be issued. Plans to route to Fire Dept.
Plans ACCEPTED BY PLAN TECH  7/16/2003 DONE
1. Plans not fully dimensioned.
2. Floor plan not stamped/signed by licensed Arch/Engineer.
3. No vicinity map.
4. No building code data regarding occupancy group or construction type.
(Accept plans per Jason B.)
Application received  7/15/2003  
Recd Pcfee & Taken To Pln CK  7/15/2003  
Fee Review-notes7/15/20037/15/2003