Second Notice BLD | 4/26/2005 | 4/26/2005 | 4/26/2005 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice Sent | | 8/3/2004 | 4/26/2005 | | DONE |
|
|
|
|
DOC - Permit Finaled | 8/3/2004 | 8/3/2004 | 8/3/2004 | P | PASS |
Tony Young
|
|
|
Finaled by inspector at 8/3/2004 4:00:38 PM
|
BLD-Aging Inspection | 8/2/2004 | 8/2/2004 | 8/2/2004 | | DONE |
Tony Young
|
|
|
|
BLD-Aging Inspection | 8/2/2004 | 8/2/2004 | 8/2/2004 | | DONE |
Tony Young
|
|
|
|
BLD-Framing/Rough-in | 8/20/2003 | 8/21/2003 | 8/21/2003 | A | PASS |
Carl Dependahl
|
|
|
###-#### dennis
|
BLD-Final | 8/21/2003 | 8/21/2003 | 8/21/2003 | A | PASS |
Carl Dependahl
|
|
|
ok for l/c
|
Override - Parcel Holds | | | 8/20/2003 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 8/20/2003 | | DONE |
|
|
|
|
Override - Parcel Holds | | | 8/20/2003 | | |
|
|
|
|
Override - Parcel Holds | | | 8/7/2003 | | |
|
|
|
|
Inspection Record Card- Bld | | | 8/7/2003 | | DONE |
|
|
|
|
Telephone call | | | 8/7/2003 | | DONE |
|
|
|
called left message permit was ready but advised of parcel holds with Dave Abo.
|
Plan assigned to (DRS) | 8/5/2003 | 8/5/2003 | 8/6/2003 | | PASS |
Dan Stuart
|
|
|
8/6/2003 16:16:03 DRS - activity updated through activity BLDA022 from case BLD03-01890.
|
Routing - PLAN CHECK | 8/6/2003 | | 8/6/2003 | | PASS |
|
|
|
Approved as noted on plans and atached plan review comments/conditions as part of the approved plans.
|
Override - Parcel Holds | | | 8/6/2003 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 8/6/2003 | | PASS |
|
|
|
To permit desk to issue.
|
Telephone call | | | 8/6/2003 | | DONE |
|
|
|
Talked with Pat McKeegan concerning the need for a 30" parapet extending above the roof on top of the Fire Wall or construction 1-hour roof.ceiling assembly on the joist side of the roof framing & constructing 2-hour wall tight to the underside of the roof sheating per section 705.6, exception 2. I told Pat I would red-line on the plans the 1-hour roof/ceiling assembly on the bottom of the ceiling joists. He said okay. Using assembly from Tbl. 719.1(3), item 21-1.1 for 1-hour system.
|
Application received | | | 8/5/2003 | | |
|
|
|
|
Meeting | | | 8/4/2003 | | DONE |
|
|
|
Met with Pat McKeegan & Dennis Harmon to discuss issuing a separate permit for a 2-hour party wall at property line as they had discussed with Marlene and she had discussed with me. Existing masonry wall to be modified as necessary to bring into compliance as 2-hour assembly from floor to bottom of roof deck. I-hour roof/ceiling assembly to be installed on bottom of rafter / joists to a minimum of 4 feet out on each siede of two hour wall per exception 705.6(2) in lou of installing parapet above roof.
|