(F) Reprint permit | | | 1/16/2008 | | |
|
|
|
|
Permanent Occupancy | | 2/27/2004 | 2/27/2004 | | DONE |
|
|
|
|
FIRE-Final Inspection | 2/26/2004 | 2/27/2004 | 2/27/2004 | A | PASS |
Troy Cobbley
|
|
|
Fire life safety finaled 2/27/2004 8:06:03 AM
|
BLD-Final | 2/26/2004 | 2/27/2004 | 2/27/2004 | A | PASS |
Jim Sly
|
|
|
Keith; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes OK for Perm Occ. :) 2/27/2004 10:35:34 AM
|
First Notice | | 2/27/2004 | 2/27/2004 | | DONE |
|
|
|
|
Permanent occupancy UNPAID FEE | | | 2/27/2004 | | DONE |
|
|
|
Perm. Occ. Cert. #10010 issued 2-27-04 to the Home Depot.
|
BLD-Final | 2/25/2004 | 2/26/2004 | 2/26/2004 | A | NR |
Jim Sly
|
|
|
keith; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Need P/Z signature. 2/26/2004 10:00:39 AM
|
BLD-Final | 2/24/2004 | 2/24/2004 | 2/24/2004 | P | CANC |
Jim Sly
|
|
|
###-#### keith
|
BLD-Framing/Rough-in | 1/27/2004 | 1/28/2004 | 1/28/2004 | A | PASS |
Jim Sly
|
|
|
phil; Phone #: ###-#### Internet Inspection Request from: Annette Moore
|
BLD-Framing/Rough-in | 1/22/2004 | 1/22/2004 | 1/22/2004 | P | PART |
Tom Arcoraci
|
|
|
bill; Phone #: ###-#### Internet Inspection Request from: Annette Moore insul ok for cover 1/22/2004 11:58:31 AM
|
BLD-Framing/Rough-in | 1/20/2004 | 1/20/2004 | 1/20/2004 | P | FAIL |
Jim Sly
|
|
|
BILL ; Phone #: ###-#### Internet Inspection Request from: Annette Moore Need new detail for top of small control room wall......Need energy code compliance statement. 1/20/2004 4:56:30 PM
|
BLD-Footing | 12/18/2003 | 12/18/2003 | 12/18/2003 | P | PART |
Jim Sly
|
|
|
Bill; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes CMU 75% complete Kleinfelder special insp on site. 12/18/2003 1:11:47 PM
|
BLD-Footing | 12/8/2003 | 12/9/2003 | 12/9/2003 | A | PART |
Jim Sly
|
|
|
Bill; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Special insp Req. for Epoxy, Conc, CMU. North wall 3hr CMU/ vermiculite fill......Kleinfelder is special insp agency. Footing OK pend special insp and approvals. 12/9/2003 9:34:02 AM
|
Issue PAID IN FULL permit | | | 12/4/2003 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 11/14/2003 | | DONE |
|
|
|
|
Print Occupancy Form | | | 11/14/2003 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 11/14/2003 | | DONE |
|
|
|
|
Telephone call | | | 11/14/2003 | | DONE |
|
|
|
Left message for Joanna that permit is ready & fees and that we need Info from ACHD
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/13/2003 | | DONE |
|
|
|
|
Plan assigned to (MLO) | 9/17/2003 | | 11/13/2003 | | PASS |
Mike Otto
|
|
|
11/13/2003 15:46:19 MLO - activity updated through activity BLDA022 from case BLD03-02235.
|
Routing - PLAN CHECK | 11/7/2003 | | 11/13/2003 | | PASS |
|
|
|
|
Plan resubmittals received | | | 11/7/2003 | | DONE |
|
|
|
Received transmittal letter, one structural calculations book, three sets of sheets A001,A101,A201,A202,A301,A302,A401,A402,A501,A502,S101,S201,M201,P201,TF1,E101,E201,E202, taken to Mike Otto.
|
Routing - PLUMBING | 10/8/2003 | | 10/10/2003 | | PASS |
|
|
|
need two inch vent between interceptor and sump, may tie into sump vent above floor
|
Routing - FIRE | 10/3/2003 | | 10/8/2003 | | PASS |
|
|
|
|
Routing - PLAN CHECK | 9/25/2003 | | 10/3/2003 | | FAIL |
|
|
|
corrections sent to architect
|
Plan resubmittals requested | | | 10/3/2003 | | DONE |
|
|
|
IBC corrections
|
Plan resubmittals received | | | 9/25/2003 | | DONE |
|
|
|
Recieved United Water Letter. Put with plans and file. kmm
|
Plans ACCEPTED BY PLAN TECH | | | 9/24/2003 | | DONE |
|
|
|
received signed declaration form and Affidavit of legal interest. Routed to Mike O and file. kmm
|
Routing - PLANNING | 9/23/2003 | | 9/24/2003 | | PASS |
|
|
|
Approve per DRH03-157
|
Routing - Erosion and Sediment | 9/22/2003 | | 9/23/2003 | | PASS |
|
|
|
ESC approved under bld03-02278.
|
Routing - PUBLIC WORKS | 9/17/2003 | | 9/22/2003 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 9/19/2003 | | DONE |
|
|
|
Received ESC application plans and narrative.
|
Additional plans submitted | | | 9/18/2003 | | DONE |
|
|
|
Received two copies of ESC plans sheets 3 , 4 and two copies of plan narrative. Put with plans. KMM
|
Routing - PLANNING Land Div | 9/17/2003 | | 9/17/2003 | | PASS |
|
|
|
Approved. ROS 1260.
|
Plans ACCEPTED BY PLAN TECH | | | 9/16/2003 | | PEND |
|
|
|
Waiting for ESC plans and , Arch eng. form and signed involved party sheet. kmm
|
Application received | | | 9/15/2003 | | |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | | | |
|
|
|
|