Second Notice BLD | 4/26/2005 | 4/26/2005 | 4/26/2005 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 2/7/2005 | 4/26/2005 | | DONE |
|
|
|
|
Permanent occupancy | | | 2/7/2005 | | DONE |
|
|
|
Perm. Occ. Cert. # 10443 issued 2-7-05 to Hugo's Deli.
|
BLD-Final | 1/26/2005 | 1/27/2005 | 1/27/2005 | A | PASS |
Lane Manuel
|
|
|
alex; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
c of o ok 1/27/2005 9:22:08 AM
|
Permanent Occupancy | | 1/27/2005 | 1/27/2005 | | DONE |
|
|
|
|
FIRE-Final Inspection | 10/25/2004 | 10/25/2004 | 10/25/2004 | P | PASS |
Troy Cobbley
|
|
|
Fire life safety finaled 10/25/2004 4:24:58 PM
|
BLD-Final | 10/4/2004 | 10/4/2004 | 10/4/2004 | P | FAIL |
Troy Cobbley
|
|
|
mount fire extinguisher at 48" 10/4/2004 4:34:15 PM
|
BLD-Conference | 3/5/2004 | 3/5/2004 | 3/5/2004 | P | DONE |
Troy Cobbley
|
|
|
I met with the door hardware contractor to discuss which doors needed which hardware 3/5/2004 3:57:48 PM
|
FIRE-Final Inspection | 2/11/2004 | 2/11/2004 | 2/11/2004 | P | FAIL |
Troy Cobbley
|
|
|
Post occupant load signs per sheet A-1.2. Provide approved door hardware, see sheet A-1.2. Verify exit signs and emergency lights operate on backup power. Provide "door to remain unlocked during business hours" sticker at the main entry/exit, see sheet A-1.2.
Mount fire extinguishers at 48", see fire review note #3. Manual flush bolts on the main entry/exit are not allowed. Automatic flush bolts are. See fire review note #3. Final fire sprinkler permit. Remove address on the 5 mile street side if not to be used. 2/11/2004 2:31:26 PM
|
BLD-Final | 2/5/2004 | 2/6/2004 | 2/6/2004 | A | FAIL |
Russ Owen
|
|
|
shawn ; Phone #: ###-#### Internet Inspection Request from: Annette Moore .Need all signatures health dept fire/life safety, also detail for soffit c/n given to contractor. 2/6/2004 4:30:09 PM
|
BLD-Other | 1/28/2004 | 1/29/2004 | 1/29/2004 | A | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 1/28/2004 at 12:50:47 PM. Contact: ###-####. ceiling grid ok. 1/29/2004 11:22:40 AM
|
BLD-Final | 1/22/2004 | 1/22/2004 | 1/22/2004 | P | CANC |
Russ Owen
|
|
|
###-#### john ceiling grid not a final 1/22/2004 3:48:01 PM
|
BLD-Framing/Rough-in | 1/22/2004 | 1/22/2004 | 1/22/2004 | P | PART |
Russ Owen
|
|
|
ceiling grid 1/22/2004 3:49:43 PM
|
BLD-Framing/Rough-in | 1/5/2004 | 1/6/2004 | 1/6/2004 | P | PART |
Russ Owen
|
|
|
Scheduled by a contractor via Hello! on 1/5/2004 at 4:54:21 PM. Contact: ###-####. need to complete oposite side of wall (south). 1/6/2004 4:28:42 PM
|
BLD-Framing/Rough-in | 12/29/2003 | 12/29/2003 | 12/29/2003 | P | PART |
Russ Owen
|
|
|
Shawn; Phone #: ###-#### or ###-####, please call for access. Internet Inspection Request from: Aimee Hughes went over the fire wall new detail from architect need listing. 12/29/2003 1:37:11 PM
|
BLD-Conference | 12/29/2003 | 12/29/2003 | 12/29/2003 | A | FAIL |
Russ Owen
|
|
|
meet with architect and contractor to go over fire wall. cell ###-####. at 9:30 am if possible. went over 1 hr wall will try to find way to eliminate ?. 12/30/2003 12:08:02 PM
|
BLD-Framing/Rough-in | 12/22/2003 | 12/23/2003 | 12/23/2003 | A | FAIL |
Russ Owen
|
|
|
Shane; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Went over requirements for 1 hr wall with contractor will consult with architect. 12/23/2003 10:19:24 AM
|
BLD-Framing/Rough-in | 12/19/2003 | 12/19/2003 | 12/19/2003 | P | FAIL |
Russ Owen
|
|
|
shane; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie posted c/n do not cover fire wall call for conference. 12/19/2003 4:28:17 PM
|
BLD-Framing/Rough-in | 12/18/2003 | 12/18/2003 | 12/18/2003 | P | FAIL |
Tom Arcoraci
|
|
|
Shane; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes 1hr wall not per plan 12/18/2003 3:47:40 PM
|
Inspection Record Card- Bld | | | 11/25/2003 | | DONE |
|
|
|
|
Print Occupancy Form | | | 11/25/2003 | | DONE |
|
|
|
|
Telephone call | | | 11/25/2003 | | DONE |
|
|
|
called left voise message for clinton permit ready & fee given 11-25-03 9:13 am ///dld
|
Issue PAID IN FULL permit | | | 11/25/2003 | | DONE |
|
|
|
|
Plan assigned to (JCB) | 10/20/2003 | | 11/24/2003 | | PASS |
Jason Blais
|
|
|
11/24/2003 09:51:52 JCB - activity updated through activity BLDA022 from case BLD03-02533.
|
Routing - PLAN CHECK | 11/20/2003 | | 11/24/2003 | | PASS |
|
|
|
Permit and plans approved and taken to front desk.
|
PLANS/APPL TAKEN TO FRONT DESK | | | 11/24/2003 | | PASS |
|
|
|
|
Plan resubmittals received | | | 11/21/2003 | | DONE |
|
|
|
Received revised sheets G2, A-1.3. Routed to Jason B. kmm
|
Telephone call | | | 11/20/2003 | | |
|
|
|
Called Clinton Yaka, architect representative, concerning one-hour fire barrier construction issues. He said he would look into it and get back to me.
|
Routing - PLAN CHECK | 11/12/2003 | | 11/20/2003 | | FAIL |
|
|
|
One-hour fire barrier construction still needs to be addressed. Called architect rep. to have them address.
|
Plan resubmittals received | | | 11/18/2003 | | DONE |
|
|
|
Received memo to Jason with two sheets of details, two sets of sheets G2,A-1.2,E1.0,E2.1D,E2.1L taken to Jason.
|
Routing - FIRE | 11/5/2003 | | 11/12/2003 | | PASS |
|
|
|
|
Plan resubmittals requested | | | 11/5/2003 | | |
|
|
|
Plan resubmittals and written response required for further review.
|
Routing - PLAN CHECK | 10/24/2003 | | 11/5/2003 | | FAIL |
|
|
|
Plan review sent and faxed to architect. Plan resubmittals and written response required for further review. Plans to route to Fire Dept. for review.
|
Routing - PLUMBING | 10/24/2003 | | 10/24/2003 | | PASS |
|
|
|
install floor sink at relocated soda dispenser to recieve discharge from required R.P. and ice maker drain, if an automatic soap dispensor is installed at the mop sink, provide a water supply for it, if water heater platform is over 8' a.f.f., provide a permenantly fastened ladder .
|
Routing - PUBLIC WORKS | 10/20/2003 | | 10/24/2003 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 10/20/2003 | | DONE |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 10/16/2003 | | DONE |
|
|
|
|
Application received | | | 10/15/2003 | | |
|
|
|
|
Fee Review-notes | 10/16/2003 | 10/16/2003 | | | |
|
|
|
|