Permit Information
Permit NumberBLD03-02579
StatusExpired
Name GRILL DINO
Site Address 5220 W FAIRVIEW AVE
Project NameFAIRVIEW SQUARE
Customer Number 
ePlanReviewNo
Description
(GRILL DINO) To remodel a 2,300 sq.ft. building for use as a restaurant, the previous occupnant was one-hour photo, all work to be per approved plans. Work will include, installation of a Type-I hood system, construction of a one-hour fire-rated grease duct shaft, construction of two accessible restrooms, installation of plumbing fixtures, construction of noncombustible wall to locate hood against, miscelaneous related kitchen appliances and interior finishes. (PC#664-03) rmh (NOTE THE TYPE ONE HODD SYSTEM HAS NOT BEEN INSTALLED AS OF 5/20/04 / A TEMPORARY OCCUPANCY HAS BEEN GRANTED FOR 90 DAYS. ALL COOKING IS BEING PERFORMED OUTSIDE. THIS PERMIT IS ACTIVE FOR UNTIL 8/20/04.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Other5/18/20055/18/20055/18/2005 DONE
Tenant gone, building is vacant
Permit EXPIRED  5/18/2005 DONE
Vacant, tenant moved out
BLD-Aging Inspection9/29/20049/29/20049/29/2004 NR
DetailsCathy Weisshaupt
BLD-Aging Inspection7/26/20047/26/20047/26/2004 PASS
DetailsTom Arcoraci
on temp 7/26/2004 8:57:53 AM
Print Occupancy Form  5/20/2004 DONE
Temporary occupancy  5/20/2004 DONE
Temp. Occ. cert. # 5113 issued 5-20-04 to Grill Dino.
BLD-Final5/18/20045/19/20045/19/2004APART
DetailsTom Arcoraci
###-#### or ###-#### Dado ok for temp when others sign 5/19/2004 11:54:09 AM
Code Occupancy Approval5/20/20045/19/20045/19/2004PDONE
DetailsScott M.Brown
NO REAL ZONING REQUIREMENTS HER AND NO OUT DOOR CHANGES, TOLD THEM TO MOVE TRAILER WHEN RESTRAUNT OPEN AND PULL WEEDS. BECAUSE NO REAL CHANGES I SIGNED CARD FOR FINAL. 5/20/2004 12:37:47 PM
FIRE-Final Inspection5/14/20045/18/20045/18/2004APART
DetailsRick Jackson
Dado; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes Temp occupancy approved pending deletion of Type I hood from approved 5/18/2004 10:07:44 AM
FIRE-Final Inspection5/11/20045/11/20045/11/2004PFAIL
DetailsTroy Cobbley
Mount fire extinguishers at 48". Provide approved door hardware on all doors. Lever type is ok. See building dept. review note #12. Provide sticker over main exit per review note #9. Provide occupant load sign per review note #11. Remove all dead bolts on the exterior doors. Provide type one hood and suppression system or variance. 5/11/2004 3:42:08 PM
Plan assigned to (R_H)10/24/2003 2/13/2004 PASS
Details
2/13/2004 14:00:52 RMH - activity updated through activity BLDA022 from case BLD03-02579.
Routing - PLAN CHECK11/20/2003 2/13/2004 PASS
Plan resubmittals received  2/13/2004 DONE
Received letter of transmittal with one copy of A-1.3
Inspection Record Card- Bld  2/13/2004 DONE
Inspection Record Card- Bld  2/13/2004 DONE
CHANGE STATUS TO (R)  2/13/2004 DONE
Telephone call  2/13/2004 DONE
called peter permit ready & fee given 1:52 2-13-04 ///dld
PLANS/APPL TAKEN TO FRONT DESK  2/13/2004 DONE
Issue PAID IN FULL permit  2/13/2004 DONE
Plan resubmittals received  2/12/2004 DONE
Received two copies of revised sheets A-1.1, A-1.2, A-1.3. One copy of response letter. Routed to Ron Hill. kmm
CHANGE STATUS TO (PND)  2/3/2004 DONE
I accidentally put plans in issue status. Changed back to pending. kmm
Routing - PLUMBING12/24/2003 12/24/2003 PASS
BENCH SEWER IS OK WITH EXISTING GREASE INTERCEPTOR AS PER OUR CONVERSATION 12/23/03, INDIRECT WASTE RECEPTOR MUST BE SIZED TO PREVENT SPLASHING AND FLOODING.
Routing - FIRE11/14/2003 11/19/2003 PASS
Review faxed to architect.
Routing - PLAN CHECK11/6/2003 11/14/2003 FAIL
Faxed and mailed requirements to the architect on 11/14/03, Routed plans to the fire department same day.
Routing - PLUMBING11/3/2003 11/6/2003 FAIL
existing indirect waste receptor must be sized to prevent flooding and splashing. contact bench sewer district about grease interception requirements prior to plumbing plan review.
Routing - PLANNING10/27/2003 10/31/2003 PASS
Approved per building permit plans and as noted on Key Plan, which states that landscaping shall be restored along Fairview Avenue and that the drive-up window is not approved or part of this permit.
Routing - PUBLIC WORKS10/24/2003 10/27/2003 PASS
Plans ACCEPTED BY PLAN TECH  10/22/2003 PEND
<$10,000 Mech. plan not stamped or signed. kmm
Application received  10/20/2003  
Recd Pcfee & Taken To Pln CK  10/20/2003 DONE
Fee Review-notes10/20/200310/20/2003