Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD03-02635
StatusFinaled
Name STUBS SPORTS PUB
Site Address 3662 S FINDLEY AVE
Project NameFAMILY CENTER-BLDG A1
Customer Number 
ePlanReviewNo
Description
(STUBS SPORTS PUB)(FAMILY CENTER-BLDG A1) To construct a 1,965 sq.ft. sports bar per approved plans. This space is at the south end of the building. Work to include, construction of two accessible restrooms, construction of partitions to divide kitchen restrooms and dinning areas, installation of related kitchen appliances, installation of a type-2 hood system above oven, new counters, sinks and miscelaneous related interior finishes. New Hvac system and lighting. This building is fully fire sprinkled for area increase, any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. (pc#679-02) rmh
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
First Notice 1/27/20041/27/2004 DONE
Permanent occupancy UNPAID FEE  1/27/2004 DONE
Perm. Occ. Cert. #9945 issued 1-27-04 to Stubs Sports Pub.
Permanent Occupancy 1/26/20041/26/2004 DONE
Details
BLD-Final1/26/20041/26/20041/26/2004PPASS
DetailsJim Storey
final ok
FIRE-Final Inspection1/20/20041/21/20041/21/2004APASS
DetailsRick Jackson
jack; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
BLD-Final1/20/20041/21/20041/21/2004PPART
DetailsJim Storey
jack; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie temp ok 1/21/2004 3:29:19 PM
FIRE-Conference1/15/20041/15/20041/15/2004APART
DetailsRick Jackson
met with GC while testing the fire alarm; will need emergency lighting; occupant load sign and address for final; requested data for Auto-Fry to clarify if it is capable of providing a contact for connection to fire alarm upon activation of self contained extinguishing system 1/15/2004 9:24:17 AM
BLD-Framing/Rough-in12/9/200312/10/200312/10/2003PPASS
DetailsJim Storey
Jack; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
Case Summary (BLD)  12/10/2003  
Plan assigned to (R_H)10/27/2003 11/21/2003 PASS
Details
11/21/2003 11:04:45 RMH - activity updated through activity BLDA022 from case BLD03-02635.
Routing - PLAN CHECK11/21/2003 11/21/2003 DONE
Case Summary (BLD)  11/21/2003 DONE
PLANS/APPL TAKEN TO FRONT DESK  11/21/2003 DONE
Inspection Record Card- Bld  11/21/2003 DONE
Print Occupancy Form  11/21/2003 DONE
Telephone call  11/21/2003 DONE
Spoke with Scott told him permit is ready & fees
Permit Ready to Issue  11/21/2003 DONE
Issue PAID IN FULL permit  11/21/2003 DONE
Routing - PLUMBING11/19/2003 11/20/2003 PASS
resubmittals ok
Routing - PLAN CHECK11/17/2003 11/18/2003  
Plan resubmittals received  11/18/2003 DONE
Received letter of transmittal with two sets of sheets P1,P2 taken to Ron Hill.
Routing - PUBLIC WORKS11/14/2003 11/17/2003 PASS
Routing - PLAN CHECK11/14/2003 11/14/2003  
Routing - FIRE11/6/2003 11/14/2003 PASS
Plan resubmittals received  11/13/2003 DONE
rececived two EN1 sheets taken to Ron.
Plan resubmittals received  11/12/2003 DONE
Received two copies of revised sheets A1, EN1, P-1 and P-2. One copy of cover letter. Routed to Ron Hill. kmm
Routing - PLAN CHECK10/31/2003 11/6/2003 FAIL
Mailed and faxed requirements to the architect on 11/06/03, Routed plans to the fire department same day.
Routing - PLUMBING10/28/2003 10/30/2003 PASS
25 gpm big dipper for 3-comp. and prep sink will be installed.
Plans ACCEPTED BY PLAN TECH  10/28/2003 DONE
Routing - PUBLIC WORKS10/27/2003 10/28/2003 FAIL
Electro/mech. point source, grease abatement is required per Walt Baumgartner. kmm
Plans ACCEPTED BY PLAN TECH  10/27/2003 PEND
Need to have mech. compliance form signed.
Application received  10/24/2003  
Recd Pcfee & Taken To Pln CK  10/24/2003  
Fee Review-notes10/24/200310/24/2003