Second Notice BLD | 4/26/2005 | 4/26/2005 | 4/27/2005 | | DONE |
|
|
|
First Notice has not been responded to.
|
First Notice | | 11/19/2004 | 4/26/2005 | | DONE |
|
|
|
|
Permanent occupancy | | | 11/19/2004 | | DONE |
|
|
|
Perm. Occ. Cert. # 10364 issued 11-19-04 to Napa Auto Parts.
|
Permanent Occupancy | | 11/15/2004 | 11/15/2004 | | DONE |
|
|
|
|
BLD-Final | 11/15/2004 | 11/15/2004 | 11/15/2004 | P | PASS |
Dave Hannah
|
|
|
Jeff; Phone #: ###-#### Internet Inspection Request from: Cheryl Baumgartner ok fo perm occ 11/15/2004 1:03:17 PM
|
FIRE-Final Inspection | 10/21/2004 | 10/21/2004 | 10/21/2004 | P | PASS |
Rick Jackson
|
|
|
|
BLD-Aging Inspection | 8/2/2004 | 8/2/2004 | 8/2/2004 | | NR |
Tony Young
|
|
|
|
BLD-Final | 12/26/2003 | 12/29/2003 | 12/29/2003 | A | PART |
Dave Hannah
|
|
|
###-#### dave ok for temp occ ok for perm after fire and pz signs perm 12/29/2003 9:36:18 AM
|
FIRE-Final Inspection | 12/24/2003 | 12/26/2003 | 12/26/2003 | A | PART |
Troy Cobbley
|
|
|
A temporary occupancy was given until the fire alarm plans are approved, installed and inspected 12/26/2003 10:00:10 AM
|
FIRE-Final Inspection | 12/23/2003 | 12/24/2003 | 12/24/2003 | A | NR |
Rick Jackson
|
|
|
temp occupancy can be approved after fire alarm upgrade submittals are received and assigned an FIR permit number; all outstanding items have been corrected 12/24/2003 12:01:35 PM
|
BLD-Final | 12/23/2003 | 12/24/2003 | 12/24/2003 | A | CANC |
Dave Hannah
|
|
|
|
BLD-Final | 12/22/2003 | 12/23/2003 | 12/23/2003 | P | NR |
Dave Hannah
|
|
|
###-#### Tim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
|
FIRE-Final Inspection | 12/23/2003 | 12/23/2003 | 12/23/2003 | P | NR |
Rick Jackson
|
|
|
TIM ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie all other items completed; awaiting alarm plans 12/23/2003 1:55:42 PM
|
FIRE-Final Inspection | 12/19/2003 | 12/19/2003 | 12/19/2003 | A | FAIL |
Rick Jackson
|
|
|
main exit to be keyed both sides; door hardware on east and south exit doors; need ceiling tiles on second floor; repair exit sign located at hallway to second exit; attempted to locate fire sprinklering monitoring alarm panel - the owner believes the only panel is the ADT security panel that is monitoring the sprinkler system - the sprinkler monitoring system will require 24 hr battery back-up (note 4 on plan review); manual pull and smoke detector above panel and monitoring of the HVAC detectors in NAPA TI; there is one detector for HVAC shut down in the NAPA TI and there appears to be a total of three HVAC units in the TI space that would require detectors for unit shutdown 12/19/2003 10:17:01 AM
|
BLD-Final | 12/18/2003 | 12/18/2003 | 12/18/2003 | P | NR |
Russ Owen
|
|
|
Tim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes needs fire/life safety and zoning, went over some items with contractor that would need to be addressed. 12/18/2003 4:10:03 PM
|
Plan assigned to (R_H) | 11/14/2003 | | 12/15/2003 | | PASS |
|
|
|
12/15/2003 10:21:03 RMH - activity updated through activity BLDA022 from case BLD03-02763.
|
Routing - PLAN CHECK | 12/11/2003 | | 12/15/2003 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 12/15/2003 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 12/15/2003 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 12/15/2003 | | DONE |
|
|
|
|
Print Occupancy Form | | | 12/15/2003 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 12/15/2003 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 12/15/2003 | | DONE |
|
|
|
|
Routing - FIRE | 12/12/2003 | | 12/12/2003 | | PASS |
Bill Alexander
|
|
|
|
Routing - PLAN CHECK | 12/8/2003 | | 12/11/2003 | | |
|
|
|
|
Routing - PLANNING | 12/11/2003 | | 12/11/2003 | | PASS |
|
|
|
Approved per CZC03-169.
|
Plan resubmittals received | | | 12/10/2003 | | DONE |
|
|
|
Received transmittal letter with a letter to Ron and two sets of sheets A1.0, A2.0 taken to Ron
|
Routing - FIRE | 12/5/2003 | | 12/8/2003 | | FAIL |
Bill Alexander
|
|
|
Need information in regards to IFC 23, 27 and 34. Reference attached review comments.
|
Plan Review Completed(1st rev) | | | 12/8/2003 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 11/19/2003 | | 12/5/2003 | | FAIL |
|
|
|
Faxed and mailed corrections to the architect on 12/5/03, Routed plans to the fire department same day.
|
Routing - PLANNING | 11/17/2003 | | 11/19/2003 | | FAIL |
|
|
|
Exterior does not comply with CZC03-169.
|
Routing - PUBLIC WORKS | 11/14/2003 | | 11/17/2003 | | PASS |
|
|
|
|
Plans ACCEPTED BY PLAN TECH | | | 11/13/2003 | | DONE |
|
|
|
|
Application received | | | 11/12/2003 | | |
|
|
|
|
Recd Pcfee & Taken To Pln CK | | | 11/12/2003 | | DONE |
|
|
|
|
Fee Review-notes | 11/12/2003 | 11/12/2003 | | | |
|
|
|
|