Permit Information
Permit NumberBLD04-00038
StatusFinaled
Name THE REEF RESTAURANT
Site Address 105 S 6TH ST
Project NameSTATESMAN BUILDING
Customer Number 
ePlanReviewNo
Description
(THE REEF RESTAURANT - OLD STATESMAN BLDG - 2ND FLR) This building is fire sprinklered to substitute for 1-hr fire-resistance-rated construction. To remodel an existing 6,416 square foot 2nd floor restaurant tenant space for a new restaurant tenant and to expand the floor area by constructing a 1,704 square foot 2nd floor outdoor terrace over an existing roof. Work is to include 2 restrooms altered to be accessible to the disabled, interior nonbearing walls, interior stairways, new roof beams, expanded openings in existing masonry walls, kitchen equipment, millwork, and finishes. The terrace will be supported by existing masonry walls and will be constructed of steel beams, wood joists, and "TREX" decking. The terrace will have one rooftop structure having a steel frame and palm roofing and one rooftop structure having steel frames and noncombustible roofing. A demolition permit (BLD04-00048) was issued earlier. DRH03-00224 **CJW** CONSTRUCTION OF THE TERRACE SHALL NOT COMMENCE UNTIL ALL THE CONCERNS OF THE CONSULTANT ENGINEER HAVE BEEN RESOLVED. (3-17-04) THE TERRACE DESIGN WAS APPROVED BY THE CONSULTANT ENGINEER ON MARCH 15, 2004. **CJW**
Contact Information
See Activities list for contact information
Color Key
Current location of plans being reviewed:  
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Case Summary (BLD)  3/9/2016 DONE
Case Summary (BLD)  3/9/2016 DONE
Case Summary (BLD)  5/16/2007  
Third Notice BLD5/20/20055/20/200512/9/2005 DONE
Second Notice has not been responded to.///Over a year old No final values
Second Notice BLD4/26/20054/26/20055/20/2005 DONE
First Notice has not been responded to.
First Notice 7/15/20044/26/2005 DONE
Permanent occupancy UNPAID FEE  7/15/2004 DONE
Perm. Occ. Cert. # 10227 issued 7-14-04 to the Reef Restaurant.
BLD-Final7/13/20047/13/20047/13/2004PPASS
DetailsDave Hannah
ok for perm occ 7/13/2004 12:45:19 PM
Permanent Occupancy 7/13/20047/13/2004 DONE
Details
BLD-Final7/1/20047/2/20047/2/2004APART
DetailsDave Hannah
kent; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok for temp occ on out side area also 7/2/2004 10:51:13 AM
FIRE-Final Inspection7/1/20047/1/20047/1/2004PPASS
DetailsRick Jackson
Phase 2 (terrace) is completed; fire final okay for perm occupancy 7/1/2004 4:08:08 PM
FIRE-Final Inspection6/29/20046/30/20046/30/2004PNR
DetailsRick Jackson
Kent; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes The fire sprinkler work for the terrace is not ready 6/30/2004 2:29:26 PM
BLD-Final6/29/20046/30/20046/30/2004PNR
DetailsDave Hannah
Kent; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
Code Occupancy Approval  6/29/2004 PASS
OK SO SIGNED OFF FINAL, ONLY QUESTION WAS COLOR OF UNPAINED BRICKS, THEY ARE GOING TO CLEAN PAINT OFF AND GO NATURAL BRICKS SOON, FINAL SIGNED OFF
BLD-Conference6/14/20046/14/20046/14/2004PDONE
DetailsDave Hannah
kent; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
FIRE-Conference6/14/20046/14/20046/14/2004PPART
DetailsRick Jackson
kent; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Met with GC about sprinkler requirements for new bar 6/14/2004 3:15:58 PM
Temporary occupancy  6/4/2004 DONE
Temp. Occ. cert. # 5118 issued 6-4-04 to the Reef Restaurant.
BLD-Final6/3/20046/3/20046/3/2004PPART
DetailsDave Hannah
###-#### kent ok for temp occ owner will open the int part and work on the outside area int still needs ada signage at rest rooms 6/3/2004 4:03:14 PM
FIRE-Final Inspection6/3/20046/3/20046/3/2004PPART
DetailsRick Jackson
Phase I completed - the terrace isn't ready to occupy but the rest of the area is okay to occupy 6/3/2004 4:28:16 PM
BLD-Conference6/1/20046/2/20046/2/2004ADONE
DetailsDave Hannah
BLD-Conference6/2/20046/2/20046/2/2004PDONE
DetailsDave Hannah
Kent; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIRE-Conference6/2/20046/2/20046/2/2004PCANC
DetailsRick Jackson
Kent; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes inspection scheduled for 6/3 6/2/2004 1:26:18 PM
BLD-Conference6/1/20046/1/20046/1/2004PCANC
DetailsDave Hannah
Kent; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIRE-Conference5/13/20045/13/20045/13/2004APART
DetailsRick Jackson
Met with Kent and left correction notice concerning the bamboo and thatch canopies. After conferring with Carl Westphall, Sam Rogers, Dave Miller and Dave Hannah the Fire Stop fire retardant is approved with the following requirements: the thatch must be immersed for treatment, a special inspector shall be obtained after presenting credentials to plan review for approval to observe the materials are treated per manufacturer's instruction and a test of treated materials will conducted with the inspectors present to verify it meets the criteria specified by Fire Stop; open flames are not permitted 5/13/2004 12:47:51 PM
FIRE-Conference5/4/20045/5/20045/5/2004APART
DetailsRick Jackson
kent; Phone #: ###-#### Internet Inspection Request from: Barbara Moore Met with Kent about the bamboo and thatch canopies that were being installed; they weren't shown on the approved plans; left correction notice to provide flame spread and smoke development and if fire treated to provide certification from manufacturer of fire treatment 5/5/2004 2:14:18 PM
BLD-Conference4/28/20044/29/20044/29/2004PDONE
DetailsDave Hannah
kent; Phone #: ###-#### Internet Inspection Request from: Annette Moore
FIRE-Sprinkler Rough-in4/15/20044/16/20044/16/2004APART
DetailsRick Jackson
kent; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Combustible cavity under stage area has been filled with insulation 4/16/2004 10:48:15 AM
BLD-Conference4/15/20044/15/20044/15/2004PDONE
DetailsDave Hannah
kent; Phone #: ###-#### Internet Inspection Request from: Darla Downs
FIRE-Conference4/6/20044/7/20044/7/2004APART
DetailsRick Jackson
Scheduled by a contractor via Hello! on 4/6/2004 at 10:03:09 AM. Met with electrical GC and Larry Rose; a new fire alarm panel will be installed with submitals; the kitchen extinguishing system will require monitoring by new panel 4/7/2004 3:04:26 PM
BLD-Framing/Rough-in3/16/20043/17/20043/17/2004APART
DetailsDave Hannah
KENT; Phone #: ###-#### Internet Inspection Request from: Darla Downs kitchen and food prep area ok to cover steel stud walls after elec and plb r/is 3/18/2004 8:10:14 AM
Routing Off Site - STRUCTURAL3/12/2004 3/17/2004 PASS
Design approved by the Consultant Engineer.
Print Occupancy Form  3/12/2004 DONE
Permit Ready to Issue  3/12/2004 DONE
Telephone call  3/12/2004 DONE
permit ready and fee due
Issue PAID IN FULL permit  3/12/2004  
Inspection Record Card- Bld  3/12/2004 DONE
Routing - PLAN CHECK3/2/2004 3/12/2004 PASS
(3-5-04) Reviewed resubmitted drawings and sent the engineering packet to the consultant engineer. Waiting for the results of the consultant engineer's resubmittal review. All other items were resolve. (3-9-04) Consultant engineer completed 2nd review. Some items still need resolution. (3-12-04) The 3rd structural resubmittal was a "deferred review" and approval was delayed until reviewed and approved by the consultant engineer. Otherwise the drawings were approved. (3-17-04) Design approved by the Consultant Engineer.
Plan assigned to (CJW)1/13/2004 3/11/2004 PASS
DetailsCarl Westfall
3/11/2004 18:36:31 CJW - activity updated through activity BLDA022 from case BLD04-00038.
Plan resubmittals received  3/11/2004 DONE
Received letter of transmittal with response letter, two copies of supplemental structural calculations. taken to Carl W.
PLANS/APPL TAKEN TO FRONT DESK  3/11/2004 PASS
The resolution of the unresolved structural issues were deffered to a later date.
Routing Off Site - STRUCTURAL3/5/2004 3/9/2004 FAIL
Sent resubmittals to outside engineering via PDQ.
Routing - PLUMBING2/27/2004 3/2/2004 PASS
additional cross connection protection may be required, if an automatic soap dispensor is installed at the mop sink, provide a water supply for it. per plans and 2000 upc.
Plan resubmittals received  2/27/2004 DONE
Received a letter of transmittal, two page letter from Glancey Rockwell,revised certificate of value, two page letter regarding structural responses,two copies of supplimental structural calculations. three sets of A-0.1,A-1.1,A-1.2,A-1.3,A-1.4,A-2.1,A-2.2,A-4.1,A-6.1,A-6.2,A-6.3,S1.0,S2.0,S2.1,S3.0,S3.1, taken to Carl W.
Routing - PUBLIC WORKS2/26/2004 2/27/2004 PASS
Routing - FIRE2/19/2004 2/25/2004 PASS
Routing - PLAN CHECK1/20/2004 2/19/2004  
Failed first IBC plan review. IBC plan review started February 7, 2004 and was finished February 19, 2004. A response from the architect and engineer was required. See the plan review report. A copy was E-mailed to the architect's representative.
Routing Off Site - STRUCTURAL1/30/2004 2/10/2004 FAIL
Contacted PDQ to take plans to outside engineering. KMM

Failed first review by structural consultant. CJW
Plan resubmittals received  1/22/2004 DONE
Received letter of transmittal, three copies of multiple fixture sizing suggestions,three sets of sheets P-2.1 taken to Carl W.
Routing - PUBLIC WORKS1/14/2004 1/15/2004  
Failed first review.
Old grease trap must upgrade to electro/med
D/W area pre rinse sink must route to grease abatement equipment.
Satay Bar - major cook area adjacent sinks must route to grease line.
Routing - PLANNING1/15/2004 1/15/2004 DONE
Jeff Neberman DRH03-00224
Routing - Erosion and Sediment1/14/2004 1/14/2004 PASS
Received ESC plan and RP. kmm\\passed for Demo bld03-00048
Routing - PUBLIC WORKS1/13/2004 1/14/2004 DONE
Took plans from PW to route to ESC for demo. kmm
Application received  1/12/2004  
Recd Pcfee & Taken To Pln CK  1/12/2004 DONE
Plans ACCEPTED BY PLAN TECH  1/12/2004 DONE
Routing - PLUMBING1/20/2004 1/20/2003 DONE
no review, pw is requireing that the drainage plans be redrawn, review after pw is happy with design.
Fee Review-notes1/12/20041/12/2004   
Routing Off Site - STRUCTURAL3/12/2004    
Send supplimental engineering to Stapley for review. 3-12-04 Called PDQ for pickup.rad