Permit Information
Permit NumberBLD04-00044
StatusFinaled
Name EXPRESS
Site Address 350 N MILWAUKEE ST Unit: 2097
Project NameBTS - #2097
Customer Number 
ePlanReviewNo
Description
(EXPRESS)(BOISE TOWNE SQUARE-SPACE 2097) To remodel three tenant spaces 2097,2096, & 2098 to create one new 6,859 sq.ft. tenant per approved plans. Work to include, construction of all new noncombustible partitions, new storefront, installation of three roll-up security grills, installation of suspended ceiling, construction of two new accessible restrooms, installation of rack storage per engineering, installation of miscelaneous counters, cabinets and shelving and related finishes. This building is fully fire sprinklered and contains a smoke evacuation system, any alterations or modifications to the sprinkler system shall be per NFPA #13 as regulated by the fire department. The smoke evacuation system shall be maintained as installed under the 1985 UBC. (pc#015-04) RMH
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD5/20/20055/20/200510/24/2005 DONE
Second Notice has not been responded to.
Telephone call  10/10/2005 DONE
Spoke with PLM Con (Kurt) and asked for change orders due to value differences///10/10/05 BAS
Second Notice BLD4/26/20054/26/20055/20/2005 DONE
First Notice has not been responded to.
First Notice 5/11/20044/26/2005 DONE
Permanent occupancy  5/11/2004 DONE
Perm. Occ. Cert. # 10129 issued 5-11-04 to Express at Boise Towne Square.
BLD-Final5/10/20045/10/20045/10/2004PPASS
DetailsRuss Owen
Scheduled by a contractor via Hello! on 5/10/2004 at 10:02:29 AM. Contact: ###-####. ok perm oc. 5/10/2004 4:03:53 PM
FIRE-Final Inspection5/5/20045/6/20045/6/2004APASS
DetailsTroy Cobbley
fire life safety finaled 5/6/2004 11:21:08 AM
BLD-Final5/5/20045/6/20045/6/2004PPART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 5/5/2004 at 2:13:26 PM. Contact: ###-####. need accessible counters.ok for temp oc. 5/6/2004 5:30:54 PM f 5/6/2004 5:30:56 PM 5/6/2004 5:31:12 PM
FIRE-Final Inspection5/5/20045/5/20045/5/2004PFAIL
DetailsTroy Cobbley
Patch holes in rated wall in storeroom areas. Move smoke detector in open ceiling area to deck.
BLD-Final5/3/20045/5/20045/5/2004PCANC
DetailsRuss Owen
Scheduled by a contractor via Hello! on 5/3/2004 at 1:22:20 PM. Contact: ###-####., needs fire life safety, failed this pm. 5/5/2004 1:47:30 PM
BLD-Framing/Rough-in3/31/20044/1/20044/1/2004APASS
DetailsRuss Owen
Scheduled by a contractor via Hello! on 3/31/2004 at 2:34:48 PM. Contact: ###-####.
BLD-Framing/Rough-in3/23/20043/24/20043/24/2004APART
DetailsRuss Owen
Scheduled by a contractor via Hello! on 3/23/2004 at 10:03:36 AM. Contact: ###-####. Ok except some changes over the front roll up doors, need addl detail from engineer, contractor on site notified. 3/23/2004 9:38:14 PM
Issue PAID IN FULL permit  2/24/2004 DONE
Plan assigned to (R_H)1/15/2004 2/20/2004 PASS
Details
2/20/2004 08:07:48 RMH - activity updated through activity BLDA022 from case BLD04-00044.
Routing - PLAN CHECK2/20/2004 2/20/2004 PASS
PLANS/APPL TAKEN TO FRONT DESK  2/20/2004 DONE
Permit Ready to Issue  2/20/2004 DONE
Inspection Record Card- Bld  2/20/2004 DONE
Print Occupancy Form  2/20/2004 DONE
Print Occupancy Form  2/20/2004 DONE
Telephone call  2/20/2004 DONE
Left message that permit is ready & fees//2/20/04 10:07am BAM
Routing - FIRE2/17/2004 2/19/2004 PASS
Acceptable per review comments.
Case Summary (BLD)  2/17/2004 DONE
Routing - PLAN CHECK2/6/2004 2/17/2004 PEND
Resubmittals reviewed and approved by building department, Routed plans back to fire for review and sign off, Permit pending fire departments approval. 2/17/04
Plan resubmittals received  2/13/2004 DONE
Received a memo with three sets of sheets E00.0,E05.2, taken to Ron H.
Plan resubmittals received  2/12/2004 DONE
Received three sets of sheets A00.0,A00.2,A04.1,A08.3,E03.1,E03.4,S01.1, taken to Ron H.
Plan resubmittals received  2/12/2004 DONE
Received three copies of revised sheets. Three copies of energy compliance for envelope one copy of response letter and three copies of Structural Calcs. Routed to Ron H. kmm
Routing - FIRE2/2/2004 2/6/2004 FAIL
PFE's to be addressed in resubmiital. Review comments faxed to architect.
Routing - PLAN CHECK1/20/2004 2/2/2004 FAIL
Faxed and mailed corrections to the architect and the job manager on 2/2/04, Routed plans to the fire department same day.
Routing - PUBLIC WORKS1/15/2004 1/20/2004 PASS
Application received  1/13/2004  
Recd Pcfee & Taken To Pln CK  1/13/2004 DONE
Plans ACCEPTED BY PLAN TECH  1/13/2004 PASS
Fee Review-notes1/13/20041/13/2004