Third Notice BLD | 12/7/2005 | 12/7/2005 | 12/15/2005 | | DONE |
|
|
|
Second Notice has not been responded to.///Signed off 2004 permit per Jenifer & Rita
|
Second Notice | | 5/20/2005 | 12/7/2005 | | DONE |
|
|
|
|
First Notice | | 11/3/2004 | 4/26/2005 | | DONE |
|
|
|
|
Permanent occupancy UNPAID FEE | | | 11/3/2004 | | DONE |
|
|
|
Perm. Occ. Cert. #10348 issued 11-3-04 to Al's Car Care.
|
Permanent Occupancy | | 10/29/2004 | 10/29/2004 | | DONE |
|
|
|
|
BLD-Final | 10/29/2004 | 10/29/2004 | 10/29/2004 | P | PASS |
Tom Arcoraci
|
|
|
Randy; Phone #: ###-#### Internet Inspection Request from: Jan Rice
|
Code Occupancy Approval | 10/27/2004 | 10/27/2004 | 10/27/2004 | P | PASS |
Scott M.Brown
|
|
|
ALL IN NOW WILL SIGN FINAL WHEN IN CITY HALL 10/27/2004 3:16:19 PM
|
Temporary occupancy | | | 10/19/2004 | | DONE |
|
|
|
Temp. Occ. Cert. # 5157 issued 10-19-04 to Al's Car Care.
|
FIRE-Final Inspection | 10/14/2004 | 10/15/2004 | 10/15/2004 | A | PASS |
Rick Jackson
|
|
|
Scheduled by a contractor via Hello! on 10/14/2004 at 2:22:23 PM. Contact: ###-####.
|
BLD-Final | 10/14/2004 | 10/15/2004 | 10/15/2004 | P | PART |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 10/14/2004 at 2:24:57 PM. Contact: ###-####. ok for temp occ 10/15/2004 3:44:15 PM
|
PubWorks Occupancy Approval | 10/13/2004 | 10/13/2004 | 10/13/2004 | | DONE |
|
|
|
Drainage project complete, signed permanent occupancy 10/13/04. D.Erskine
|
FIRE-Conference | 10/11/2004 | 10/12/2004 | 10/12/2004 | A | FAIL |
Troy Cobbley
|
|
|
Spoke to superintendant about painting of curbing for the fire dept access 10/12/2004 10:29:42 AM
|
Code Occupancy Approval Temp | 10/12/2004 | 10/12/2004 | 10/12/2004 | P | DONE |
Scott M.Brown
|
|
|
TEMP ONLY DUE TO 1. FENCE IN BUT NOT SLATED AND LIGHT IN S.E. CORNER MAY BE TO BRIGHT ON RESIDENTIAL PROPERTY NEXT DOOR, I WAS TOLD THEY HAVE NOT BEEN TURNED ON YET, WILL RECHECK MONDAY THE 18TH 10/12/2004 3:16:51 PM
|
BLD-Framing/Rough-in | 9/20/2004 | 9/20/2004 | 9/20/2004 | P | NR |
Lane Manuel
|
|
|
Scheduled by a contractor via Hello! on 9/20/2004 at 7:38:45 AM. Contact: ###-####.
need r-mech insp. prior to r-framing 9/20/2004 4:20:40 PM
|
BLD-Framing/Rough-in | 9/13/2004 | 9/13/2004 | 9/13/2004 | A | PART |
Lane Manuel
|
|
|
Scheduled by a contractor via Hello! on 9/13/2004 at 7:31:08 AM. Contact: ###-####.
recheck for hangers @ trusses @ hip/jack locations, and ledger area 9/13/2004 10:44:22 AM
|
BLD-Framing/Rough-in | 9/8/2004 | 9/9/2004 | 9/9/2004 | P | PART |
Lane Manuel
|
|
|
Scheduled by a contractor via Hello! on 9/8/2004 at 12:01:35 PM. Contact: ###-####.
roofnailing @ front "popout" section ok 9/9/2004 1:32:15 PM
|
BLD-Conference | 7/9/2004 | 7/12/2004 | 7/12/2004 | A | PASS |
Tom Arcoraci
|
|
|
Scheduled by a contractor via Hello! on 7/9/2004 at 2:59:12 PM. Contact: ###-####. 7/12/2004 9:32:28 AM pending spec insp 7/12/2004 10:01:01 AM
|
BLD-Conference | 7/2/2004 | 7/6/2004 | 7/6/2004 | P | CANC |
Dave Hannah
|
|
|
randy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
(F) Reprint permit | | | 6/16/2004 | | |
|
|
|
|
Inspection Record Card- Bld | | | 6/15/2004 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 6/15/2004 | | DONE |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/26/2004 | | DONE |
|
|
|
|
Print Occupancy Form | | | 5/26/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/26/2004 | | DONE |
|
|
|
|
Telephone call | | | 5/26/2004 | | DONE |
|
|
|
permit ready and fee due
|
Plan assigned to (MLO) | 2/23/2004 | | 5/26/2004 | | PASS |
Mike Otto
|
|
|
5/26/2004 08:57:48 MLO - activity updated through activity BLDA022 from case BLD04-00281.
|
Routing - PLANNING Land Div | 5/25/2004 | | 5/25/2004 | | PASS |
|
|
|
Approved.
|
Telephone call | | | 5/25/2004 | | DONE |
|
|
|
Call from contractor stating that property issue has been cleared. Plans routed to Planning Land.
|
Routing - FIRE | 5/10/2004 | | 5/12/2004 | | PASS |
|
|
|
resubmittal acceptable
|
Routing - FIRE | 4/30/2004 | | 5/6/2004 | | FAIL |
|
|
|
Resubmittal requried for Boise Fire Department vehicle access and turnaround requirements.
|
Plan resubmittals received | | | 5/6/2004 | | DONE |
|
|
|
Received Transmittal Letter 1 Set 2 Sheets SD-1.1 Taken to Mike Otto
|
Routing - PLAN CHECK | 4/30/2004 | | 4/30/2004 | | PASS |
|
|
|
modification has been approved for 2003 IBC compliance. MLO
|
Routing Off Site - STRUCTURAL | 4/30/2004 | | 4/30/2004 | | DONE |
|
|
|
Contacted PDQ to take resubmitted plans of 4-19-04 to out side Engineers.
|
Plan resubmittals received | | | 4/20/2004 | | DONE |
|
|
|
Received three copies of revised sheets SD-1.1, C1.0, C1.3, S2.1, A-1.1, A-5.1, A-5.2, M2.1, M3.1. One copy of response letter. One letter from Stapley and one copy of scope of work. Routed to Mike O. kmm
|
Routing - FIRE | 4/2/2004 | | 4/5/2004 | | FAIL |
Bill Alexander
|
|
|
Need clarification of occupancy use other than "Minor" and related verification meeting minimum IFC requirements.
|
Plan Review Completed(1st rev) | | | 4/5/2004 | | DONE |
|
|
|
|
Plan resubmittals requested | | | 4/2/2004 | | DONE |
|
|
|
IBC and structural corrections
|
Routing Off Site - STRUCTURAL | 2/23/2004 | | 4/2/2004 | | FAIL |
|
|
|
Contacted PDQ for outside engineering. rad 3/8/04 Sent struct. calcs. to outside engineering. kmm
3/17/04 Routed pre-engineered plans and calcs. to outside eng. kmm
|
Routing - PLAN CHECK | 3/29/2004 | | 4/2/2004 | | FAIL |
|
|
|
corrections sent to architect
|
Routing - PLUMBING | 3/23/2004 | | 3/29/2004 | | PASS |
|
|
|
use approved interceptor design, pipe hydrant system through r.p. interceptor vents must not be combined, must have 12.56 sq. inches of venting upstream of interceptor.
|
Routing - PLANNING | 3/19/2004 | | 3/23/2004 | | PASS |
|
|
|
Approved per DRH04-2.
|
Routing - Erosion and Sediment | 3/3/2004 | | 3/19/2004 | | PASS |
|
|
|
ESC approved with attached conditions.
|
Plan resubmittals received | | | 3/16/2004 | | DONE |
|
|
|
Received letter of transmittal with plans and calcs that are not 18X24 in size, I called Jane to let her know. rad
3/17/04 Routed two copies of R&M Steel calculations and plans to Mike O. and routed one copy to outside engineering. kmm
|
Telephone call | | | 3/15/2004 | | DONE |
|
|
|
Left a message for Clinton at BRS that we need three sets of Premanufactured building plans and calcs.
|
Telephone call | | | 3/8/2004 | | DONE |
|
|
|
Outside engineering called, asking for Structural Calcs. Will see if they are with the plans and route to them. kmm
|
Routing - PUBLIC WORKS | 2/25/2004 | | 3/3/2004 | | PASS |
|
|
|
|
Routing - PLANNING Land Div | 2/23/2004 | | 2/24/2004 | | FAIL |
|
|
|
Parcel has been surveyed but has not been split because a deed has not been recorded. Also need a new tax parcel #. Called Clinton Yaka on 2/24/2004.
|
Plans ACCEPTED BY PLAN TECH | | | 2/23/2004 | | DONE |
|
|
|
|
Plan routing begun/NEW & ADDTN | | | 2/23/2004 | | DONE |
|
|
|
|
Application received | | | 2/20/2004 | | |
|
|
|
|
Routing - PLAN CHECK | 4/21/2004 | | 4/29/2003 | | PEND |
|
|
|
Pending mod approval for occupancy separation per 2003 IBC.
|