BLD-Final | 9/1/2004 | 9/2/2004 | 9/2/2004 | A | PASS |
Tony Young
|
|
|
Rob;phone# ###-####
|
BLD-Grading Inspection | 9/2/2004 | 9/2/2004 | 9/2/2004 | | DONE |
|
|
|
Final grading and drainage approved.
|
DOC - Permit Finaled | 9/2/2004 | 9/2/2004 | 9/2/2004 | A | PASS |
Tony Young
|
|
|
Finaled by inspector at 9/2/2004 11:25:31 AM
|
BLD-Final | 9/1/2004 | 9/1/2004 | 9/1/2004 | P | NR |
Tony Young
|
|
|
rob; Phone #: ###-#### Internet Inspection Request from: Annette Moore
need hillside sign off 1st,,, no inspection made 9/1/2004 3:32:51 PM
|
BLD-Energy code compliance | 6/28/2004 | 6/29/2004 | 6/29/2004 | A | PASS |
Tony Young
|
|
|
rob; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
BLD-Framing/Rough-in | 6/28/2004 | 6/28/2004 | 6/28/2004 | P | PASS |
Tony Young
|
|
|
###-#### rob
|
BLD-Framing/Rough-in | 6/23/2004 | 6/24/2004 | 6/24/2004 | A | FAIL |
Tony Young
|
|
|
Rob; ###-####
c/n posted,, ok to insulate 6/24/2004 12:05:56 PM
|
BLD-Conference | 6/23/2004 | 6/23/2004 | 6/23/2004 | P | PART |
Tony Young
|
|
|
Rob; phone ###-####
w/ framer 6/24/2004 12:39:23 PM
|
BLD-Framing/Rough-in | 6/22/2004 | 6/22/2004 | 6/22/2004 | P | NR |
Tony Young
|
|
|
Rob; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
need to complete what is on plans/ engineering 6/23/2004 12:45:06 PM
|
BLD-Framing/Rough-in | 6/3/2004 | 6/4/2004 | 6/4/2004 | P | PART |
Tony Young
|
|
|
gordon ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
ext shear ok 6/4/2004 4:39:12 PM
|
BLD-Footing | 4/28/2004 | 4/28/2004 | 4/28/2004 | A | PART |
Tony Young
|
|
|
Scheduled by a contractor via Hello! on 4/28/2004 at 7:18:25 AM. Contact: ###-####.
|
BLD-Footing | 4/27/2004 | 4/27/2004 | 4/27/2004 | P | NR |
Tony Young
|
|
|
Rob; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
need soil report 1st,,, no inspection 4/27/2004 3:18:36 PM
|
BLD-Grading Inspection | 4/27/2004 | 4/27/2004 | 4/27/2004 | | PASS |
Rita DeYoung
|
|
|
fOOTING SUBGRADE APPROVED
|
(F) Reprint permit | | | 4/22/2004 | | DONE |
|
|
|
|
Issue PAID IN FULL permit | | | 4/15/2004 | | DONE |
|
|
|
|
Case Summary (BLD) | | | 4/14/2004 | | |
|
|
|
|
Plan Review Report | | | 4/14/2004 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 4/14/2004 | | DONE |
|
|
|
|
Print Occupancy Form | | | 4/14/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 4/14/2004 | | DONE |
|
|
|
|
Telephone call | | | 4/14/2004 | | DONE |
|
|
|
permit ready and fee due
|
Routing - PLAN CHECK | 4/7/2004 | | 4/14/2004 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 4/8/2004 | | 4/14/2004 | | PASS |
Steve Munroe
|
|
|
4/14/2004 09:04:05 SAM - activity updated through activity BLDA022 from case BLD04-00481.
|
Plan Reviewer's activity | | | 4/9/2004 | | DONE |
|
|
|
4/9/04 I called and left a message for Eric, the engineer, to call me. Plans are on hold till I hear from him. I need to know interior footing / pier sizes.
|
Pending Assignment by DJO | 3/18/2004 | | 4/8/2004 | | DONE |
Dan Overy
|
|
|
4/8/2004 10:29:39 SAM - activity updated through activity BLDA183 from case BLD04-00481.
|
Routing - PUBLIC WORKS GRADING | 3/18/2004 | | 4/7/2004 | | PASS |
Rita DeYoung
|
|
|
Approved as category 3. 4/7/04
top of footing is at grade. 4/6/04
Approved pending receipt of minor grading revisions.3/19/04
Adequate setback from slope at rear not provided. Grades are flat at side of house so water from slope at rear will pond. Spoke with DJT at Pinnacle 3/19 AM
|
Routing - FIRE | 3/30/2004 | | 3/30/2004 | | DONE |
|
|
|
No fire sprinklers required - Eyrie Canyon #2.
|
Routing - Erosion and Sediment | 3/24/2004 | | 3/29/2004 | | PASS |
|
|
|
ESC approved with conditions attached to plans.
|
Routing - PLANNING | 3/22/2004 | | 3/23/2004 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 3/19/2004 | | 3/22/2004 | | PASS |
|
|
|
NORTHWEST BOISE SEWER DISTRICT
|
Application received | | | 3/18/2004 | | |
|
|
|
|