Permit Information
Permit NumberBLD04-00717
StatusFinaled
Name RMF INC
Site Address 1649 N AMBER ST
Project Name 
Customer Number 
ePlanReviewNo
Description
(RMF) This building is fully sprinklered to reduce fire flow requirements to 1,500 gpm per '97 UFC. To remodel a 3,214 sq.ft. space, previously completed as a "Vanilla Finish", for use as a motor vehicle repair shop (exchange of parts, no work on fuel systems declared by owner/tenant) / customer pick-up area and an non-combustible automotive parts storage area, all to become part of the existing RMF, Inc. Auto Repair complex per approved plans. Existing RFM Auto repair is approximately 5,715 sq. ft. This expansion will bring the total area to 8,930 sq. ft. A 1-hour fire barrier (FB) is constructed between the existing and new auto repair areas and a new 1-hr FB wall will be created between the "S1" parts storage area per Tbl. 302.1.1 Incidental Use & the new auto repair area. The 1-hour walls will also be used to provide three 1-hour Control Areas. The accessory use customer waiting / office areas, less than 10% are not required to be separated. PC04-195/drs
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Third Notice BLD5/20/20055/20/200511/1/2005 DONE
Second Notice has not been responded to.
Second Notice BLD4/26/20054/26/20055/20/2005 DONE
First Notice has not been responded to.
First Notice 3/18/20054/26/2005 DONE
BLD-Final3/17/20053/18/20053/18/2005APASS
DetailsTom Arcoraci
Scheduled by a contractor via Hello! on 3/17/2005 at 12:18:46 PM. Contact: ###-####. ok for perm 3/18/2005 9:42:02 AM
Permanent Occupancy 3/18/20053/18/2005 DONE
Details
Permanent occupancy UNPAID FEE  3/18/2005 DONE
Perm. Occ. Cert. # 10502 issued 3-18-05 to RMF, Inc.
FIRE-Final Inspection3/16/20053/16/20053/16/2005PPASS
DetailsTroy Cobbley
Fire life safety finaled 3/16/2005 4:55:00 PM
BLD-Framing/Rough-in2/8/20052/8/20052/8/2005PPASS
DetailsTroy James
Scheduled by a contractor via Hello! on 2/8/2005 at 8:04:55 AM. Contact: ###-####.
BLD-Aging Inspection12/23/200412/23/200412/23/2004 NR
DetailsTom Arcoraci
Issue PAID IN FULL permit  9/23/2004 DONE
OVERRIDE  9/22/2004  
Override - People Holds  9/22/2004  
Inspection Record Card- Bld  9/22/2004 DONE
Print Occupancy Form  9/22/2004 DONE
PLANS/APPL TAKEN TO FRONT DESK  9/22/2004 PASS
Ready to process for issuing.
Override - People Holds  9/22/2004  
Permit Ready to Issue  9/22/2004 DONE
Telephone call  9/22/2004 DONE
left mess that permit is ready
Plan assigned to (DRS)4/16/2004 9/22/2004 PASS
DetailsDan Stuart
9/22/2004 07:54:49 DRS - activity updated through activity BLDA022 from case BLD04-00717.
Routing - PLAN CHECK9/21/2004 9/22/2004 PASS
Ready to take to permit desk for issue.
Routing - FIRE9/15/2004 9/21/2004 PASS
Resubmittal acceptable.
Received Certificate of Value  9/15/2004 DONE
Received new C.V. from architect to address aditional work to be done.
Routing - PLAN CHECK9/1/2004 9/15/2004 PEND
Received further clarification & plan sheet A2.00 from architect. Still missing updated CV for new values to include electrical & plumbing. Architect will provide ASAP. Routing to fire code analyst for re-review.
Plan resubmittals received  9/14/2004  
Received Transmittal Letter, & 2 copys of A2.00 Taken to Dan S. ....
Plan resubmittals received  9/3/2004 DONE
Received Transmittal Letter & Memorandum Letter...Taken to Dan S.
Routing - PLAN CHECK5/20/2004 9/1/2004 FAIL
Received resubmittals from architect on 8/31/04 & inserted into plans this day. New Sheet A2.0 & first time mechancal sheets. Resubmittals were incomplete as the hazardous materials used and or stored were not addressed as part of resubmittals and the mechanical ventilation for the enclosed parking garage was not addressed. I talked with the architect, Dave Blodgett concerning these items and he had not addressed the haz mat question yet and he thought the original enclosed parking garage was possibly going to be storage only (not vehicles). The repair garage area had a mechanical plan but it was unclear as what events triggered the use of the systems specified, i.e. does the activation of the CO sensor activate the exhaust which activates the fresh air unit which will activate the new overhead gas heat unit when temperature of the habitable space drops below 50 degrees? I told Dave Blogettall items need to be considered and clearly addressed and the proposed occupancy uses groups needed to be clearly addressed so there woud be no misunderstanding as to code requirements applicable to the project.
Plan resubmittals received  8/31/2004 DONE
Received response letter with three sets of sheets A2.00,EN1.0,M0.0,MO.1,M1.0,taken to Dan S.
Telephone call  7/1/2004 DONE
Called back Owen Tennison, Elkhorn Engineering, concerning this project and plan review comments faxed and mailed to David Blodgett on 5/17/04 concerning plan resubmittals providing mechancial design data and required equipment, if any needing to be added to the building for the proposed new occupancy uses' for this portion of the existing building. Owen wanted to verify what I was requiring. I ask him to read the code sections referenced and provide evaluation and evidience of compliance with code and show what was needed in design details or table or both to clearly indicate requirements. this information would be used by the mechanical field inspector to verify compliance with code in the field.He said he would clarify what he would need to do with the architect and provide said documentation and details accordingly if approved by the design professional.
Routing - FIRE5/17/2004 5/20/2004 FAIL
Need Haz Mat info; review comments faxed to architect.
Plan resubmittals requested  5/17/2004 FAIL
Copy of plan review faxed and mailed to David Blodgett, architect.
Routing - PLAN CHECK4/21/2004 5/17/2004 FAIL
Resubmittals required. Copy of review to David Blodgett. Routing to fire code analyst while waiting for response.
Routing - PUBLIC WORKS4/16/2004 4/20/2004 PASS
Routing - PLANNING4/20/2004 4/20/2004 PASS
Approved per building permit plans.
Plans ACCEPTED BY PLAN TECH  4/15/2004 DONE
<$1000.0
Application received  4/12/2004  
Recd Pcfee & Taken To Pln CK  4/12/2004  
Fee Review-notes9/22/20049/22/2004   
Fee Review-notes4/12/20044/12/2004