BLD-Final | 9/27/2004 | 9/27/2004 | 9/27/2004 | P | PASS |
Troy James
|
|
|
kirk ###-####-- re-insp
|
DOC - Permit Finaled | 9/27/2004 | 9/27/2004 | 9/27/2004 | P | PASS |
Troy James
|
|
|
Finaled by inspector at 9/27/2004 1:59:27 PM
|
BLD-Final | 9/22/2004 | 9/24/2004 | 9/24/2004 | A | CANC |
Troy James
|
|
|
kirk; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles Canc per cathy in office 9/23/2004 9:41:00 AM
|
BLD-Framing/Rough-in | 7/27/2004 | 7/27/2004 | 7/27/2004 | P | PASS |
Troy James
|
|
|
kirk; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Energy code compliance | 7/27/2004 | 7/27/2004 | 7/27/2004 | P | PASS |
Troy James
|
|
|
kirk; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Framing/Rough-in | 7/26/2004 | 7/26/2004 | 7/26/2004 | P | FAIL |
Troy James
|
|
|
kurt; Phone #: ###-#### Internet Inspection Request from: Annette Moore
Need to install holddowns at garage and front of house. Need to install strap on top plate above stairs. Need to install additional micro west to east at front part of house per plans. Need temp glass above stairs. 7/26/2004 2:15:21 PM
|
BLD-Foundation | 5/28/2004 | 6/1/2004 | 6/1/2004 | A | PASS |
Dave Hannah
|
|
|
|
BLD-Foundation | 5/28/2004 | 6/1/2004 | 6/1/2004 | A | PASS |
Dave Hannah
|
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD-Foundation | 5/26/2004 | 5/28/2004 | 5/28/2004 | A | CANC |
Dave Hannah
|
|
|
chris; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 5/28/2004 | | |
|
|
|
|
BLD-Footing | 5/26/2004 | 5/26/2004 | 5/26/2004 | P | CANC |
Russ Owen
|
|
|
###-#### chris
|
BLD-Footing | 5/26/2004 | 5/26/2004 | 5/26/2004 | A | PART |
Russ Owen
|
|
|
wip. 5/26/2004 12:15:25 PM
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 5/26/2004 | | |
|
|
|
|
Override - Parcel Holds | 1/1/1900 | 1/1/1900 | 5/26/2004 | | |
|
|
|
needed found
|
Override - Parcel Holds | | | 5/26/2004 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 5/10/2004 | | DONE |
|
|
|
|
Routing - PLAN CHECK | 4/23/2004 | | 5/3/2004 | | DONE |
|
|
|
|
Plan assigned to (SAM) | 4/30/2004 | | 5/3/2004 | | PASS |
Steve Munroe
|
|
|
5/3/2004 09:42:28 SAM - activity updated through activity BLDA022 from case BLD04-00822.
|
Case Summary (BLD) | | | 5/3/2004 | | |
|
|
|
|
Plan Review Report | | | 5/3/2004 | | |
|
|
|
|
PLANS/APPL TAKEN TO FRONT DESK | | | 5/3/2004 | | DONE |
|
|
|
|
Inspection Record Card- Bld | | | 5/3/2004 | | DONE |
|
|
|
|
Permit Ready to Issue | | | 5/3/2004 | | DONE |
|
|
|
|
Telephone call | | | 5/3/2004 | | DONE |
|
|
|
permit ready and fee due
|
Pending Assignment by DJO | 4/21/2004 | | 4/30/2004 | | DONE |
Dan Overy
|
|
|
4/30/2004 15:44:24 SAM - activity updated through activity BLDA183 from case BLD04-00822.
|
Routing - PLANNING | 4/22/2004 | | 4/23/2004 | | PASS |
|
|
|
|
Routing - PUBLIC WORKS | 4/23/2004 | | 4/23/2004 | | PASS |
|
|
|
|
Routing - PLANNING Land Div | 4/21/2004 | | 4/22/2004 | | PASS |
|
|
|
Lot 20, Block 17, John Krall Addition
|
Application received | | | 4/21/2004 | | |
|
|
|
|